Permit: TC-COM-0925-01704
Permit Details
Status:
Inspections
Type:
Commercial Building
Address:
1500 E TUCSON MARKETPLACE BL
Address NEW:
1500 E TUCSON MARKETPLACE BL
Apply Date:
09/18/2025
Applicant:
Kolbe Neilsen
Description:
Infill installation of 5 EV chargers in parking lot and Canopy
Permit Reviews
Permit Number - TC-COM-0925-01704
Permit Status: Inspections
Permit Description: Infill installation of 5 EV chargers in parking lot and Canopy
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 06/23/2026 | ADMINISTRATIVE v.2 | 06/23/2026 | APPROVED |
| 01/14/2026 | COMMERCIAL REVIEW - FULL v.3 | 02/06/2026 | APPROVED |
| 06/23/2026 | SPECIAL INSPECTION REVIEW v.1 | 06/25/2026 | APPROVED |
| 11/12/2025 | COMMERCIAL REVIEW - FULL v.2 | 12/04/2025 | REQUIRES RESUBMIT |
| 09/19/2025 | COMMERCIAL REVIEW - FULL v.1 | 10/20/2025 | REQUIRES RESUBMIT |
| 02/06/2026 | ADMINISTRATIVE v.1 | 02/06/2026 | REQUIRES RESUBMIT |
Outstanding Activity Conditions
Permit Number - TC-COM-0925-01704
Permit Status: Inspections
Permit Description: Infill installation of 5 EV chargers in parking lot and Canopy
Total Outstanding Activity Conditions - 5
| Date | Name |
|---|---|
| 01/14/2026 | SPECIAL INSPECTION FOR EPOXY ANCHORS IS REQUIRED. |
| 01/14/2026 | SPECIAL INSPECTION FOR HIGH STRENGTH BOLTING IS REQUIRED. |
| 01/14/2026 | SPECIAL INSPECTION FOR SPECIAL MOMENT RESISTING STEEL FRAMES IS REQUIRED. |
| 01/14/2026 | SPECIAL INSPECTION FOR WELDING IS REQUIRED. |
| 02/03/2026 | Please submit a separate sign permit for an signs associated with this projet. |
Conditions
Permit Number - TC-COM-0925-01704
Permit Status: Inspections
Permit Description: Infill installation of 5 EV chargers in parking lot and Canopy
| Date | Description | Comments |
|---|---|---|
| 09/19/2025 | Contractor with active Arizona Contractor's License for specified scope of work required prior to issuance of permit. Contractor must have a TDC Online account and be added to the permit as a contact. | |
| 09/19/2025 | Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. For review and assessment: apply online at https://permits.pima.gov/ or contact us at sewer@pima.gov, (520) 724-9900. | |
| 12/03/2025 | A Special Inspections Intermediate Certificate must be submitted and reviewed prior to issuance of this permit. |
Outstanding Inspections
Permit Status: Inspections
Permit Number: TC-COM-0925-01704
Permite Description: Infill installation of 5 EV chargers in parking lot and Canopy
Total Outstanding Inspections - 3
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/28/2026 | COT - LCEL - Electrical Underground | N/A | Partial Pass | 8-28-26: approximately 80' of a 4' trench containing 8-3" Schedule 40 electrical feeder conduits. Trench runs north to south along eastern side of site-okay to backfill progress areas using shading materials. Also inspected trench with 6-4” Schedule 40 electrical conduits for SES. Okay to backfill progress areas. |
| 10/01/2026 | ENGR Engineering Final | N/A | Not Ready | Regarding curb ramp at south side of the PAAL at south end of crosswalk and site. This ramp should not be poured as is- Due to the existing landing at top being over 2% cross slope and the type 1 curb and crosswalk at bottom also also being over 2% cross slope. The asphalt PAAL where this crosswalk is proposed leading to the EV chargers exceeds 2% cross slope. In addition the landing at the bottom of the curb ramp on the north side of PAAL exceeds 2% cross slope. Engineer of record should design a solution to make these conditions comply. |
| 09/18/2026 | COT - LCBU - Excavation/Rebar/Zoning | N/A | Partial Pass | Excessive cross slope at radius, and at bottom landing. all changes in direction must be less than 2% in any direction. Ensure that all ramps remain less than 8.3% |