Permit: TC-COM-0925-01618
Permit Details
Status:
Inspections
Type:
Commercial Building
Address:
8300 E VALENCIA RD BLDG 24
Address NEW:
8300 E VALENCIA RD BLDG 24
Apply Date:
09/03/2025
Applicant:
Chris Guinter
Description:
A-FAMILY STORAGE - VALENCIA BLDG 24
Permit Reviews
Permit Number - TC-COM-0925-01618
Permit Status: Inspections
Permit Description: A-FAMILY STORAGE - VALENCIA BLDG 24
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 02/13/2026 | COMMERCIAL REVIEW - FULL v.3 | 02/24/2026 | APPROVED |
| 01/06/2026 | COMMERCIAL REVIEW - FULL v.2 | 01/30/2026 | REQUIRES RESUBMIT |
| 02/24/2026 | RESTAMP - COMMERCIAL v.1 | 02/25/2026 | APPROVED |
| 09/03/2025 | COMMERCIAL REVIEW - FULL v.1 | 09/29/2025 | REQUIRES RESUBMIT |
Outstanding Activity Conditions
Permit Number - TC-COM-0925-01618
Permit Status: Inspections
Permit Description: A-FAMILY STORAGE - VALENCIA BLDG 24
Total Outstanding Activity Conditions - 4
| Date | Name |
|---|---|
| 09/25/2025 | SPECIAL INSPECTION of Anchor bolts installed in concrete IS REQUIRED. |
| 09/25/2025 | SPECIAL INSPECTION of Concrete reinforcing IS REQUIRED. |
| 09/25/2025 | SPECIAL INSPECTION FOR HIGH STRENGTH BOLTING IS REQUIRED. |
| 09/25/2025 | SPECIAL INSPECTION OF SOILS IS REQUIRED. |
Conditions
Permit Number - TC-COM-0925-01618
Permit Status: Inspections
Permit Description: A-FAMILY STORAGE - VALENCIA BLDG 24
| Date | Description | Comments |
|---|---|---|
| 02/24/2026 | The Contractor you have added to your permit cannot be verified. Please contact staff to have the ROC number added to the account. | |
| 09/03/2025 | Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. For review and assessment: apply online at https://permits.pima.gov/ or contact us at sewer@pima.gov, (520) 724-9900. | |
| 02/24/2026 | A Special Inspections Intermediate Certificate must be submitted and reviewed prior to issuance of this permit. |
Outstanding Inspections
Permit Status: Inspections
Permit Number: TC-COM-0925-01618
Permite Description: A-FAMILY STORAGE - VALENCIA BLDG 24
Total Outstanding Inspections - 1
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/02/2026 | COT - LCEL - Electrical Underground | N/A | Partial Pass | 7-2-26: verified trench depth at 43" on a 4" Schedule Conduit from TEP transformer to building intended for main panel. Okay to backfill approximately 190' of trench using shading materials. |
Completed Inspections
Permit Status: Inspections
Permit Number: TC-COM-0925-01618
Permit Description: A-FAMILY STORAGE - VALENCIA BLDG 24
Total Completed Inspections - 6
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/03/2026 | COT - LCPL - Backwater Valve | Passed | 3/3/26: Partial pass for rough soil at slab (6" sleeve installed on 4" PVC for protection under exterior footing). Approved for backfill. 1-way clean out and BWV installed and approved. Pending cleanout after BWV and continuation of sewer line. | |
| 03/03/2026 | COT - LCPL - Rough Soil | Passed | 3/3/26: Partial pass for rough soil at slab (6" sleeve installed on 4" PVC for protection under exterior footing). Approved for backfill. 1-way clean out and BWV installed and approved. Pending cleanout after BWV and continuation of sewer line. | |
| 03/10/2026 | COT - LCBU - Excavation/Rebar/Zoning | Passed | 03/10/2026 Approved per building site plan, reinforcement details. Okay for concrete placement. |
|
| 03/10/2026 | COT - LCBU - Preslab | Passed | 03/10/2026 Approved per building site plan, reinforcement details. Okay for concrete placement. |
|
| 06/25/2026 | COT - LCPL - Sewer | Passed | 6-25-26: verified trench depth at 2' on a 4" SDR35 PVC sewer pipe with tracer wire under test. Okay to backfill approximately 125' of trench using shading materials. | |
| 07/01/2026 | COT - LCPL - Yard Water Line | Passed | 07/01/2026 1" PEX with blue tracer wire holding under test, run of ~70ft to building. Okay to backfill, shading required. |