Permit: TC-COM-0923-02226
Permit Details
Status:
Complete
Type:
Commercial Building
Address:
10165 E OLD VAIL RD
Address NEW:
10165 E OLD VAIL RD
Apply Date:
09/19/2023
Applicant:
Edward Yunkherr
Description:
New Commercial shell Building
Permit Reviews
Permit Number - TC-COM-0923-02226
Permit Status: Complete
Permit Description: New Commercial shell Building
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 01/04/2024 | RESTAMP - COMMERCIAL v.1 | 01/09/2024 | APPROVED |
| 12/20/2024 | COMMERCIAL REVIEW - FULL REVISION v.1 | 01/14/2025 | APPROVED |
| 02/06/2025 | BUILDING DEFERRED SUBMITTAL REVIEW v.1 | 02/06/2025 | APPROVED |
| 12/04/2024 | BUILDING DEFERRED SUBMITTAL REVIEW v.1 | 12/05/2024 | APPROVED |
| 01/14/2025 | RESTAMP - COMMERCIAL v.1 | 01/19/2025 | APPROVED |
| 02/26/2025 | BUILDING DEFERRED SUBMITTAL REVIEW v.2 | 02/28/2025 | APPROVED |
| 05/07/2024 | COMMERCIAL REVIEW - FULL v.1 | 06/03/2024 | APPROVED |
| 10/31/2023 | COMMERCIAL REVIEW - FULL v.2 | 11/27/2023 | REQUIRES RESUBMIT |
| 09/20/2023 | COMMERCIAL REVIEW - FULL v.1 | 10/19/2023 | REQUIRES RESUBMIT |
| 12/14/2023 | COMMERCIAL REVIEW - FULL v.3 | 01/04/2024 | APPROVED |
| 02/11/2025 | BUILDING DEFERRED SUBMITTAL REVIEW v.1 | 02/12/2025 | REQUIRES RESUBMIT |
Conditions
Permit Number - TC-COM-0923-02226
Permit Status: Complete
Permit Description: New Commercial shell Building
| Date | Description | Comments |
|---|---|---|
| 01/14/2025 | SPECIAL INSPECTION FOR CONCRETE INSTALLATION IS REQUIRED. | |
| 09/20/2023 | Contractor with active Arizona Contractor's License for specified scope of work required prior to issuance of permit. Contractor must have a TDC Online account and be added to the permit as a contact. | |
| 01/14/2025 | SPECIAL INSPECTION FOR EPOXY ANCHORS IS REQUIRED. | |
| 01/14/2025 | SPECIAL INSPECTION FOR EXPANSION ANCHORS IS REQUIRED. | |
| 01/14/2025 | SPECIAL INSPECTION FOR FOUNDATION/EXCAVATION IS REQUIRED. | |
| 01/14/2025 | SPECIAL INSPECTION FOR HIGH STRENGTH BOLTING IS REQUIRED. | |
| 09/20/2023 | Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. Contact sewer@pima.gov for review and assessment. | |
| 02/12/2025 | SPECIAL INSPECTION FOR SITE PREPARATION IS REQUIRED. | |
| 01/14/2025 | SPECIAL INSPECTION FOR WELDING IS REQUIRED. |
Outstanding Inspections
Permit Status: Complete
Permit Number: TC-COM-0923-02226
Permite Description: New Commercial shell Building
Total Outstanding Inspections - 13
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/12/2024 | COT - HCME - Mechanical Above Ceiling | N/A | Not Applicable | |
| 10/14/2024 | COT - HCBU - Masonry Pregrout | N/A | Not Applicable | |
| 10/14/2024 | COT - HCBU - Building Above Ceiling | N/A | Re-inspection required | 10/14/24 broken trust needs to be addressed. Fire barrier should go to deck it's not mentioned in plans need RFI to determine height of fire wall. Electrical junction boxes need to be grounded. |
| 10/14/2024 | COT - HCBU - Firewall/Fire Barrier/Firestop | N/A | Re-inspection required | 10/14/24: firewalls incomplete broken trust in larger suite. Need engineering fix for trust and RFI for firewall extensions. |
| 10/14/2024 | COT - HCEL - Electrical Above Ceiling | N/A | Re-inspection required | 10/14/24: junction boxes not grounded. |
| 10/14/2024 | COT - HCEL - Electrical Intermediate | N/A | Re-inspection required | 10/14/24 broken trust needs to be addressed. Fire barrier should go to deck it's not mentioned in plans need RFI to determine height of fire wall. Electrical junction boxes need to be grounded. |
| 10/14/2024 | COT - HCME - Mechanical Final | N/A | Re-inspection required | 10/14/24: units need to be marked for heat strips to determine disconnect size. |
| 12/17/2024 | COT - HCEL - Electrical Final | N/A | Not Ready | 12-11-24, contractor not on sight. Reinspection required. 12/17/24: called Justin Anderson, phone number: (971) 563-7656. No one on site. Left voicemail (no call back), no access to site. |
| 12/09/2024 | ENGR Engineering Final | N/A | Not Ready | After drive through a pedestrian crossing is needed and a stop sign. Ramps in front of the front doors to units need to be redone or rails added. Fire room needs to be labeled. |
| 11/27/2024 | BULD - Electrical Clearance | N/A | Partial Pass | 11-27-24, approved-okay for scs to be energized. Contractor requires a revision for 2-200 amp services that were not on original plans. The plans called for a 400 amp service but the 200 amp services were installed instead. Revisions must be submitted, reviewed and approved prior to issuing C of O. |
| 01/16/2025 | COT - BULD - SWG Clearance | N/A | Not Applicable | |
| 12/19/2024 | COT - HCEL - Outdoor Lighting | N/A | Partial Pass | 12-19-24, outdoor lights around entire building installed per approved plans. ECO clearance to TEP issued to energize type 3R CT Enclosure #121. |
| COT - FCON - Fire - Final | N/A | Not Ready |
Completed Inspections
Permit Status: Complete
Permit Number: TC-COM-0923-02226
Permit Description: New Commercial shell Building
Total Completed Inspections - 25