Inspection Status: Passed
Inspection History: ENGR Engineering Final
Permit Number - TC-COM-0923-02226
Inspection Description - ENGR Engineering Final
Inspection Status - Passed
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/09/2025 | ENGR Engineering Final | Passed | CO Ready | |
| 12/05/2024 | ENGR Engineering Final | Not Ready | 1) ADA parking is out of compliance with the left space having an end to end slope of 3.1%. 2) All handicap ramps are out of compliance with a 6.5% slope exceeding the 5% minimum required without rails being needed. 3) Ramps at front doors need rails or need to be redone as the same condition exists. 5% max without rails or rails needed up to a max of 8.333% 4) Possible drive through exit is too close to the pal. 5) Ramp going down to the dumpster enclosure is exceeding the 8.333& requirement and is at 9.5%. 6) Gas line is in the accessible area. 7) Stoop coming out of the rear entrance/exit can be no,less than 36" in depth. 8) Gutter and downspout required at all exit locations for man doors. 9) No ADA parking signs. 10) Dumpster walls need to be 6’ in hgt. from the standing surface. |
|
| 12/09/2024 | ENGR Engineering Final | Not Ready | After drive through a pedestrian crossing is needed and a stop sign. Ramps in front of the front doors to units need to be redone or rails added. Fire room needs to be labeled. |