Permit: TC-COM-0824-01548
Permit Details
Status:
Complete
Type:
Commercial Building
Address:
3100 N STONE AV UNIT 100
Address NEW:
3100 N STONE AV UNIT 100
Apply Date:
08/08/2024
Applicant:
Annette Suarez
Description:
Interior tenant improvement in an existing building
Permit Reviews
Permit Number - TC-COM-0824-01548
Permit Status: Complete
Permit Description: Interior tenant improvement in an existing building
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 08/08/2024 | COMMERCIAL REVIEW - LIMITED v.1 | 08/26/2024 | REQUIRES RESUBMIT |
| 09/12/2024 | COMMERCIAL REVIEW - LIMITED v.2 | 09/25/2024 | APPROVED |
| 09/25/2024 | RESTAMP - COMMERCIAL v.1 | 09/26/2024 | APPROVED |
Conditions
Permit Number - TC-COM-0824-01548
Permit Status: Complete
Permit Description: Interior tenant improvement in an existing building
| Date | Description | Comments |
|---|---|---|
| 08/08/2024 | Please contact Pima County Addressing to verify official address. Addressing@pima.gov or 520-724-9512 | |
| 08/08/2024 | Contractor with active Arizona Contractor's License for specified scope of work required prior to issuance of permit. Contractor must have a TDC Online account and be added to the permit as a contact. |
Outstanding Inspections
Permit Status: Complete
Permit Number: TC-COM-0824-01548
Permite Description: Interior tenant improvement in an existing building
Total Outstanding Inspections - 2
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/05/2026 | COT - HCBU - Building Final | N/A | Re-inspection required | Inspection Date: 2/5/26 Status: STOPPED INSPECTION – Additional items may be added All ceiling tiles must be removed to allow verification that all work previously covered complies with approved plans and applicable codes. The following corrections are required: Return air and supply air registers must be listed for commercial use and properly supported. All flex duct must be properly supported throughout. NM cable is not approved for commercial use above the ceiling and must be removed/replaced. Open splices above the ceiling are not permitted. Exposed wiring above the ceiling must be properly enclosed. All junction box knockouts must be properly capped. Restroom must comply with all ADA requirements. Storage room must be properly identified. Exit signs must be illuminated. Ceiling insulation is missing throughout and must be installed. Flex duct located outside the building thermal envelope must be replaced. ABS piping in the water heater room must be properly capped. GFCI protection is required where applicable throughout the space. Additionally: A licensed contractor must provide a signed letter taking responsibility for underground plumbing that was covered prior to inspection approval. Walls must be opened as required to verify plumbing and venting within wall cavities. |
| 11/14/2024 | COT - HCEL - Electrical Intermediate | N/A | Partial Pass | Partial pass. Massage room receptacles in place. 11/14/2024 |
Completed Inspections
Permit Status: Complete
Permit Number: TC-COM-0824-01548
Permit Description: Interior tenant improvement in an existing building
Total Completed Inspections - 20
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/14/2024 | COT - HCBU - Framing | Passed | 11/14/2024 approved. Kickers attached to ceiling's every 4'. | |
| 12/23/2024 | COT - HCBU - Building Progress | Passed | ||
| 02/05/2026 | COT - FCON - Fire - Final | Passed | ||
| 02/05/2026 | TRSP - ROW - Final/Close-Out | Passed | ||
| 02/17/2026 | COT - HCPL - Plumbing Progress | Passed | ||
| 02/17/2026 | COT - HCME - Mechanical Final | Passed | ||
| 02/17/2026 | PDSD Heavy Commercial Building Division Pre-Construction Meeting | Passed | ||
| 02/23/2026 | ENGR Engineering Final | Passed | Passing this final inspection allows closure of this permit, and issuance of a Certificate of Occupancy, however, reinspection is still required for compliance with the massage establishment business license. | |
| 02/23/2026 | COT - HCBU - Building Final | Passed | ||
| 02/23/2026 | COT - HCEL - Electrical Final | Passed | ||
| 02/23/2026 | COT - HCEL - Electrical Intermediate | Passed | ||
| 02/23/2026 | COT - HCPL - Plumbing Final | Passed | ||
| 02/24/2026 | COT - HCBU - Building Above Ceiling | Passed | ||
| 02/24/2026 | COT - HCEL - Electrical Above Ceiling | Passed | ||
| 02/24/2026 | COT - HCME - Mechanical Intermediate | Passed | ||
| 02/24/2026 | COT - HCEL - Electrical Progress | Passed | ||
| 02/24/2026 | COT - HCPL - Plumbing Intermediate | Passed | ||
| 02/24/2026 | COT - HCME - Mechanical Above Ceiling | Passed | ||
| 02/24/2026 | COT - HCME - Mechanical Progress | Passed | ||
| 02/24/2026 | COT - HCPL - Plumbing Above Ceiling | Passed |