Permit Details

Status:
Complete
Type:
Commercial Building
Apply Date:
08/08/2024
Applicant:
Annette Suarez
Description:
Interior tenant improvement in an existing building

Permit Reviews

Permit Number - TC-COM-0824-01548
Permit Status: Complete
Permit Description: Interior tenant improvement in an existing building
Start Date Submittal Complete Date Status  
08/08/2024 COMMERCIAL REVIEW - LIMITED v.1 08/26/2024 REQUIRES RESUBMIT Review Details
09/12/2024 COMMERCIAL REVIEW - LIMITED v.2 09/25/2024 APPROVED Review Details
09/25/2024 RESTAMP - COMMERCIAL v.1 09/26/2024 APPROVED Review Details

Conditions

Permit Number - TC-COM-0824-01548
Permit Status: Complete
Permit Description: Interior tenant improvement in an existing building
Date Description Comments
08/08/2024 Please contact Pima County Addressing to verify official address. Addressing@pima.gov or 520-724-9512
08/08/2024 Contractor with active Arizona Contractor's License for specified scope of work required prior to issuance of permit. Contractor must have a TDC Online account and be added to the permit as a contact.

Outstanding Inspections

Permit Status: Complete
Permit Number: TC-COM-0824-01548
Permite Description: Interior tenant improvement in an existing building
Total Outstanding Inspections - 2
Last Inspection Date Description Inspector Results Comments
02/05/2026 COT - HCBU - Building Final N/A Re-inspection required Inspection Date: 2/5/26
Status: STOPPED INSPECTION – Additional items may be added
All ceiling tiles must be removed to allow verification that all work previously covered complies with approved plans and applicable codes.
The following corrections are required:
Return air and supply air registers must be listed for commercial use and properly supported.
All flex duct must be properly supported throughout.
NM cable is not approved for commercial use above the ceiling and must be removed/replaced.
Open splices above the ceiling are not permitted.
Exposed wiring above the ceiling must be properly enclosed.
All junction box knockouts must be properly capped.
Restroom must comply with all ADA requirements.
Storage room must be properly identified.
Exit signs must be illuminated.
Ceiling insulation is missing throughout and must be installed.
Flex duct located outside the building thermal envelope must be replaced.
ABS piping in the water heater room must be properly capped.
GFCI protection is required where applicable throughout the space.
Additionally:
A licensed contractor must provide a signed letter taking responsibility for underground plumbing that was covered prior to inspection approval.
Walls must be opened as required to verify plumbing and venting within wall cavities.
11/14/2024 COT - HCEL - Electrical Intermediate N/A Partial Pass Partial pass. Massage room receptacles in place. 11/14/2024

Completed Inspections

Permit Status: Complete
Permit Number: TC-COM-0824-01548
Permit Description: Interior tenant improvement in an existing building
Total Completed Inspections - 20
Date Description Inspector Results Comments
11/14/2024 COT - HCBU - Framing Passed 11/14/2024 approved. Kickers attached to ceiling's every 4'.
12/23/2024 COT - HCBU - Building Progress Passed
02/05/2026 COT - FCON - Fire - Final Passed
02/05/2026 TRSP - ROW - Final/Close-Out Passed
02/17/2026 COT - HCPL - Plumbing Progress Passed
02/17/2026 COT - HCME - Mechanical Final Passed
02/17/2026 PDSD Heavy Commercial Building Division Pre-Construction Meeting Passed
02/23/2026 ENGR Engineering Final Passed Passing this final inspection allows closure of this permit, and issuance of a Certificate of Occupancy, however, reinspection is still required for compliance with the massage establishment business license.
02/23/2026 COT - HCBU - Building Final Passed
02/23/2026 COT - HCEL - Electrical Final Passed
02/23/2026 COT - HCEL - Electrical Intermediate Passed
02/23/2026 COT - HCPL - Plumbing Final Passed
02/24/2026 COT - HCBU - Building Above Ceiling Passed
02/24/2026 COT - HCEL - Electrical Above Ceiling Passed
02/24/2026 COT - HCME - Mechanical Intermediate Passed
02/24/2026 COT - HCEL - Electrical Progress Passed
02/24/2026 COT - HCPL - Plumbing Intermediate Passed
02/24/2026 COT - HCME - Mechanical Above Ceiling Passed
02/24/2026 COT - HCME - Mechanical Progress Passed
02/24/2026 COT - HCPL - Plumbing Above Ceiling Passed

Documents

File Name Document Type  
COFO_FINALCOFO_COMMERCIAL (SSRS).PDF DOCUMENTS VIEW
COFT - PDSD - PERMIT CARD.PDF DOCUMENTS VIEW
CONS-CONS-2_PLAN SET_V2_V1.PDF DOCUMENTS VIEW