Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: TC-COM-0724-01365
Permit Details
Apply Date:
07/15/2024
Applicant:
Daniel Sharp
Description:
Restricted Access - New Splash Pad, play equipment, comfort station, multi-use paths and parking areas including site lighting.
Permit Reviews
Permit Number - TC-COM-0724-01365
Permit Status: Approved
Permit Description: Restricted Access - New Splash Pad, play equipment, comfort station, multi-use paths and parking areas including site lighting.
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 09/15/2025 | BUILDING DEFERRED SUBMITTAL REVIEW v.1 | 09/17/2025 | APPROVED |
| 10/08/2025 | BUILDING DEFERRED SUBMITTAL REVIEW v.1 | 10/13/2025 | APPROVED |
| 10/08/2024 | COMMERCIAL REVIEW - LIMITED v.3 | 10/16/2024 | REQUIRES RESUBMIT |
| 11/10/2025 | RESTAMP - COMMERCIAL v.1 | 11/12/2025 | APPROVED |
| 01/10/2025 | COMMERCIAL REVIEW - LIMITED v.5 | 01/10/2025 | APPROVED |
| 09/19/2024 | COMMERCIAL REVIEW - LIMITED v.2 | 10/02/2024 | REQUIRES RESUBMIT |
| 07/17/2024 | COMMERCIAL REVIEW - LIMITED v.1 | 08/02/2024 | REQUIRES RESUBMIT |
| 12/20/2024 | COMMERCIAL REVIEW - LIMITED v.4 | 12/20/2024 | REQUIRES RESUBMIT |
| 01/10/2025 | RESTAMP - COMMERCIAL v.1 | 01/15/2025 | APPROVED |
| 09/17/2025 | BUILDING DEFERRED SUBMITTAL REVIEW v.1 | 09/22/2025 | APPROVED |
Outstanding Activity Conditions
Permit Number - TC-COM-0724-01365
Permit Status: Approved
Permit Description: Restricted Access - New Splash Pad, play equipment, comfort station, multi-use paths and parking areas including site lighting.
Total Outstanding Activity Conditions - 6
| Date | Name |
|---|---|
| 08/01/2024 | WATER STERILIZATION REPORT IS REQUIRED. |
| 10/01/2024 | SPECIAL INSPECTION FOR CONCRETE CONSTRUCTION IS REQUIRED. |
| 10/01/2024 | SPECIAL INSPECTION FOR MASONRY IS REQUIRED. |
| 10/01/2024 | SPECIAL INSPECTION FOR SOILS IS REQUIRED. |
| 10/01/2024 | SPECIAL INSPECTION FOR STEEL CONSTRUCTION IS REQUIRED. |
| 10/16/2024 | SPECIAL INSPECTION FOR OUTDOOR LIGHTING IS REQUIRED. |
Conditions
Permit Number - TC-COM-0724-01365
Permit Status: Approved
Permit Description: Restricted Access - New Splash Pad, play equipment, comfort station, multi-use paths and parking areas including site lighting.
| Date | Description | Comments |
|---|---|---|
| 01/15/2025 | Contractor with active Arizona Contractor's License for specified scope of work required prior to issuance of permit. Contractor must have a TDC Online account and be added to the permit as a contact. | |
| 02/05/2025 | Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. For review and assessment: apply online at https://permits.pima.gov/ or contact us at sewer@pima.gov, (520) 724-9900. | |
| 01/07/2025 | A Special Inspections Intermediate Certificate must be submitted and reviewed prior to issuance of this permit. |
Outstanding Inspections
Permit Status: Approved
Permit Number: TC-COM-0724-01365
Permite Description: Restricted Access - New Splash Pad, play equipment, comfort station, multi-use paths and parking areas including site lighting.
Total Outstanding Inspections - 8
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/09/2025 | COT - LCBU - Excavation/Rebar/Zoning | N/A | Partial Pass | Light poles. Station (LP1034A2) (LP1046A) (LP1040A) (LP1042A1) (LP1038A2) (LP1036A) total of 6. Okay for concrete placement. 10/9/2025 |
| 11/13/2025 | COT - LCBU - Preslab | N/A | Partial Pass | Slab area for sprinkler pad; grounded and bonded. Ok to place concrete in progress. |
| 11/13/2025 | COT - LCEL - Grounding/Bonding | N/A | Partial Pass | Grounding for children’s sprinkler pad. |
| 11/14/2025 | COT - LCEL - Electrical Progress | N/A | Canceled | Canceled per contractor. 11/14/2025 |
| 11/21/2025 | COT - HCEL - Electrical Underground | N/A | Partial Pass | 11-21-25: verified 2 separate trenches with 3-Schedule 40 electrical conduits in each running from east to west in center of site. Electrical conduits range from 1 1/2" to 2" in size and are secondary conduits for parking lot lighting, scoreboard, and musco sport lighting. Okay to backfill approximately 400' of combined trenching using shading materials. |
| 10/09/2025 | COT - LCEL - Electrical Underground | N/A | Partial Pass | X1 2” x1 1 1/2” x1 1” Ml1012A under ground running south to Cristy box for disconnect at pump house. 2” From pump house to musco light B4. 1” feeding column for Ramada at station Sc1004A. Okay to backfill progress areas. Shading is required. 10/9/2025 |
| 11/26/2025 | COT - LCPL - Yard Water Line | N/A | Partial Pass | Domestic water line (1” line) from baseball back stop south approximately 275’ to back flow preventer. Ok to cover progress areas. |
| 12/01/2025 | COT - LCPL - Sewer | N/A | Partial Pass | Three inch sewer line from man hole to future restroom; approximately 100 feet, Ok to cover progress area. |
Completed Inspections
Permit Status: Approved
Permit Number: TC-COM-0724-01365
Permit Description: Restricted Access - New Splash Pad, play equipment, comfort station, multi-use paths and parking areas including site lighting.
Total Completed Inspections - 2
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/28/2025 | PDSD Building Division Pre-Construction Meeting | Passed | ||
| 10/28/2025 | COT - LCPL - Rough Soil | Passed |