Permit: TC-COM-0724-01299
Permit Details
Status:
Issued
Type:
Commercial Building
Address:
3300 N FAIRVIEW AV
Address NEW:
3300 N FAIRVIEW AV
Apply Date:
07/02/2024
Applicant:
Amy Peron
Description:
Restricted Access - This City project includes upgrades to the existing 38.25 acres Jacobs Park which proposes new softball diamonds, new pickleball courts, a multi-use court, new dog park, new restroom, new sports lighting, new perimeter asphalt path, and upgrades to existing playground surfacing, pool/splash pad fencing, irrigation renovations and a reduction in turf. The Building Permit application is for the new restroom, sports field lighting, and various fences/walls.
Permit Reviews
Permit Number - TC-COM-0724-01299
Permit Status: Issued
Permit Description: Restricted Access - This City project includes upgrades to the existing 38.25 acres Jacobs Park which proposes new softball diamonds, new pickleball courts, a multi-use court, new dog park, new restroom, new sports lighting, new perimeter asphalt path, and upgrades to existing playground surfacing, pool/splash pad fencing, irrigation renovations and a reduction in turf. The Building Permit application is for the new restroom, sports field lighting, and various fences/walls.
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 12/11/2024 | RESTAMP - COMMERCIAL v.1 | 01/09/2025 | APPROVED |
| 12/02/2025 | COMMERCIAL REVIEW - FULL v.1 | 12/04/2025 | REQUIRES RESUBMIT |
| 09/30/2024 | COMMERCIAL REVIEW - LIMITED v.2 | 10/29/2024 | REQUIRES RESUBMIT |
| 07/03/2024 | COMMERCIAL REVIEW - LIMITED v.1 | 07/25/2024 | REQUIRES RESUBMIT |
| 12/06/2024 | COMMERCIAL REVIEW - LIMITED v.4 | 12/11/2024 | APPROVED |
| 12/06/2024 | COMMERCIAL REVIEW - LIMITED v.3 | 12/06/2024 | REQUIRES RESUBMIT |
| 12/19/2025 | COMMERCIAL REVIEW - FULL v.2 | 01/13/2026 | APPROVED |
Outstanding Activity Conditions
Permit Number - TC-COM-0724-01299
Permit Status: Issued
Permit Description: Restricted Access - This City project includes upgrades to the existing 38.25 acres Jacobs Park which proposes new softball diamonds, new pickleball courts, a multi-use court, new dog park, new restroom, new sports lighting, new perimeter asphalt path, and upgrades to existing playground surfacing, pool/splash pad fencing, irrigation renovations and a reduction in turf. The Building Permit application is for the new restroom, sports field lighting, and various fences/walls.
Total Outstanding Activity Conditions - 6
| Date | Name |
|---|---|
| 07/22/2024 | SPECIAL INSPECTION FOR OUTDOOR LIGHTING IS REQUIRED. |
| 10/25/2024 | SPECIAL INSPECTION FOR CONCRETE IS REQUIRED. |
| 10/25/2024 | SPECIAL INSPECTION FOR MASONRY IS REQUIRED. |
| 10/25/2024 | Masonry Inspection Report submittal review is required. |
| 10/25/2024 | Post-Installed Anchor Inspection Report is required. |
| 10/29/2024 | WATER STERILIZATION REPORT IS REQUIRED. |
Conditions
Permit Number - TC-COM-0724-01299
Permit Status: Issued
Permit Description: Restricted Access - This City project includes upgrades to the existing 38.25 acres Jacobs Park which proposes new softball diamonds, new pickleball courts, a multi-use court, new dog park, new restroom, new sports lighting, new perimeter asphalt path, and upgrades to existing playground surfacing, pool/splash pad fencing, irrigation renovations and a reduction in turf. The Building Permit application is for the new restroom, sports field lighting, and various fences/walls.
| Date | Description | Comments |
|---|---|---|
| 12/19/2024 | Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. For review and assessment: apply online at https://permits.pima.gov/ or contact us at sewer@pima.gov, (520) 724-9900. | |
| 10/25/2024 | A Special Inspections Intermediate Certificate must be submitted and reviewed prior to issuance of this permit. |
Outstanding Inspections
Permit Status: Issued
Permit Number: TC-COM-0724-01299
Permite Description: Restricted Access - This City project includes upgrades to the existing 38.25 acres Jacobs Park which proposes new softball diamonds, new pickleball courts, a multi-use court, new dog park, new restroom, new sports lighting, new perimeter asphalt path, and upgrades to existing playground surfacing, pool/splash pad fencing, irrigation renovations and a reduction in turf. The Building Permit application is for the new restroom, sports field lighting, and various fences/walls.
Total Outstanding Inspections - 12
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/26/2026 | PDSD Building Division SIte Consultation | N/A | Partial Pass | |
| 03/24/2026 | COT - LCEL - Electrical Underground | N/A | Partial Pass | around pickleball courts. |
| 06/10/2026 | COT - LCBU - Stem Wall/Retaining Wall | N/A | Partial Pass | Partial pass. Inspection on the stem walls and columns at the comfort station. Okay for concrete placement. 6/10/2026 |
| 05/28/2026 | COT - LCBU - Masonry Pregrout | N/A | Partial Pass | |
| 09/25/2025 | COT - LCBU - Excavation/Rebar/Zoning | N/A | Partial Pass | Partial pass. Total of 6 musco lights. X3 @ 16’ (B’s) & x3 @ 12’. (A’s) ( A3-296) (A2-294) (A1-290) (B2-291) (B1-288) (B3-299). Okay for concrete placement. 9/25/2025 |
| 03/16/2026 | COT - LCBU - Preslab | N/A | Partial Pass | 3/16/2026 partial pass. Pickle ball court approved. Pending 3' section in between both half's. |
| 09/03/2026 | BULD - Electrical Clearance | N/A | Partial Pass | Partial pass. Clearance to TEP RECN. 9/3/2026 |
| 10/14/2026 | COT - LCPL - Plumbing Final | N/A | Re-inspection required | 10/14/26: ADA signage required at restrooms, water closest shall be 16-18" from side wall or partition wall. Urinal shall be no higher than 17" AFF. water heater drain pan must be properly drained. Insulation required at pex lines in mechanical room. Receptacles shall be WR in mechanical room. Proper documentation on hangers used for roof required. Label Panel over at New SES and label receptacles at park. Photocell must be properly supported above roof line. Water sterilization required prior to approval to request TCO. Site work required to be completed. R.O.W required for approval. Fire final approval required prior to approval. |
| 10/14/2026 | ENGR Engineering Final | N/A | Not Ready | Striping required, Water sterilization report required. Address step at truncated domes on SE Accessible parking. |
| 10/14/2026 | COT - LCBU - Building Final | N/A | Re-inspection required | 10/14/26: ADA signage required at restrooms, water closest shall be 16-18" from side wall or partition wall. Urinal shall be no higher than 17" AFF. water heater drain pan must be properly drained. Insulation required at pex lines in mechanical room. Receptacles shall be WR in mechanical room. Proper documentation on hangers used for roof required. Label Panel over at New SES and label receptacles at park. Photocell must be properly supported above roof line. Water sterilization required prior to approval to request TCO. Site work required to be completed. R.O.W required for approval. Fire final approval required prior to approval. |
| 10/14/2026 | COT - LCEL - Electrical Final | N/A | Re-inspection required | 10/14/26: ADA signage required at restrooms, water closest shall be 16-18" from side wall or partition wall. Urinal shall be no higher than 17" AFF. water heater drain pan must be properly drained. Insulation required at pex lines in mechanical room. Receptacles shall be WR in mechanical room. Proper documentation on hangers used for roof required. Label Panel over at New SES and label receptacles at park. Photocell must be properly supported above roof line. Water sterilization required prior to approval to request TCO. Site work required to be completed. R.O.W required for approval. Fire final approval required prior to approval. |
| 10/14/2026 | COT - LCEL - Outdoor Lighting | N/A | Re-inspection required | 10/14/26: ADA signage required at restrooms, water closest shall be 16-18" from side wall or partition wall. Urinal shall be no higher than 17" AFF. water heater drain pan must be properly drained. Insulation required at pex lines in mechanical room. Receptacles shall be WR in mechanical room. Proper documentation on hangers used for roof required. Label Panel over at New SES and label receptacles at park. Photocell must be properly supported above roof line. Water sterilization required prior to approval to request TCO. Site work required to be completed. R.O.W required for approval. Fire final approval required prior to approval. |
Completed Inspections
Permit Status: Issued
Permit Number: TC-COM-0724-01299
Permit Description: Restricted Access - This City project includes upgrades to the existing 38.25 acres Jacobs Park which proposes new softball diamonds, new pickleball courts, a multi-use court, new dog park, new restroom, new sports lighting, new perimeter asphalt path, and upgrades to existing playground surfacing, pool/splash pad fencing, irrigation renovations and a reduction in turf. The Building Permit application is for the new restroom, sports field lighting, and various fences/walls.
Total Completed Inspections - 10
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/12/2026 | COT - LCPL - Rough Soil | Passed | ||
| 02/12/2026 | COT - LCPL - Sewer | Passed | ||
| 07/20/2026 | COT - LCBU - Roof Nailing | Passed | ||
| 08/07/2026 | COT - LCBU - Preslab | Passed | ||
| 09/23/2026 | COT - LCEL - Electrical Above Ceiling | Passed | ||
| 09/23/2026 | COT - LCBU - Framing | Passed | ||
| 09/23/2026 | COT - LCPL - Yard Water Line | Passed | ||
| 10/15/2026 | TRSP - ROW - Notice of Completion | Passed | All work completed on private property and fence has been removed | |
| 10/20/2026 | COT - LCPL - Plumbing Intermediate | Passed | ||
| 10/20/2026 | COT - LCEL - Electrical Intermediate | Passed |