Permit: TC-COM-0525-00891
Permit Details
Apply Date:
05/02/2025
Applicant:
Jessica OBrien
Description:
Install (1) new equipment shelter, (1) new concrete pad. Install (1) new concrete side walk and concrete entry pad to data center.
Permit Reviews
Permit Number - TC-COM-0525-00891
Permit Status: Issued
Permit Description: Install (1) new equipment shelter, (1) new concrete pad. Install (1) new concrete side walk and concrete entry pad to data center.
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 05/07/2025 | COMMERCIAL REVIEW - LIMITED v.1 | 05/07/2025 | REQUIRES RESUBMIT |
| 04/27/2026 | COMMERCIAL REVIEW - LIMITED v.4 | 05/08/2026 | APPROVED |
| 06/02/2025 | COMMERCIAL REVIEW - LIMITED v.2 | 06/20/2025 | REQUIRES RESUBMIT |
| 05/08/2026 | ADMINISTRATIVE v.1 | 05/08/2026 | REQUIRES RESUBMIT |
| 04/24/2026 | COMMERCIAL REVIEW - LIMITED v.3 | 04/24/2026 | REQUIRES RESUBMIT |
| 05/08/2026 | RESTAMP - COMMERCIAL v.1 | 05/13/2026 | APPROVED |
Outstanding Activity Conditions
Permit Number - TC-COM-0525-00891
Permit Status: Issued
Permit Description: Install (1) new equipment shelter, (1) new concrete pad. Install (1) new concrete side walk and concrete entry pad to data center.
Total Outstanding Activity Conditions - 3
| Date | Name |
|---|---|
| 05/07/2026 | SPECIAL INSPECTION FOR Soil Bearing Capacity, SPECIAL GRADING, EXCAVATION AND FILLING IS REQUIRED. |
| 06/10/2025 | SPECIAL INSPECTION FOR BOLTS INSTALLED IN CONCRETE IS REQUIRED. |
| 06/10/2025 | SPECIAL INSPECTION FOR CONCRETE INSTALLATION IS REQUIRED. |
Conditions
Permit Number - TC-COM-0525-00891
Permit Status: Issued
Permit Description: Install (1) new equipment shelter, (1) new concrete pad. Install (1) new concrete side walk and concrete entry pad to data center.
| Date | Description | Comments |
|---|---|---|
| 06/02/2025 | Contractor with active Arizona Contractor's License for specified scope of work required prior to issuance of permit. Contractor must have a TDC Online account and be added to the permit as a contact. | |
| 05/07/2026 | Please submit a copy of the State of Arizona Installation Permit. | |
| 06/10/2025 | A Special Inspections Intermediate Certificate must be submitted and reviewed prior to issuance of this permit. | |
| 05/07/2026 | Submit a copy of the State approved construction document drawings containing their seal of approval. |
Outstanding Inspections
Permit Status: Issued
Permit Number: TC-COM-0525-00891
Permite Description: Install (1) new equipment shelter, (1) new concrete pad. Install (1) new concrete side walk and concrete entry pad to data center.
Total Outstanding Inspections - 3
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/22/2026 | COT - RSBU - Excavation/Rebar/Zoning | N/A | Partial Pass | 6-22-26: excavation/reinforcement for footings/ slab on grade verified per plans. Okay for concrete placement. |
| 08/25/2026 | COT - LCEL - Electrical Underground | N/A | Partial Pass | 8-25-26: verified trench depth at 3' on 4-4" & 2-3" schedule 40 conduits together with grounding rods at every 15' cad-welded to copper using a complete grounding ring around shelter building. Conduits & grounding verified per E1.0/Site Electrical & Grounding Plan. Okay to backfill progress areas using shading materials. |
| 11/04/2026 | COT - LCEL - Electrical Final | N/A | Re-inspection required | HVAC #1 calls for 125. 100 amp in place. Future HVAC #5 calls for 70. 100 amp in place. Provide cover plates at open j boxes. Ensure all boxes are labeled. Provide labeling for main distribution panel. Provide full size breaker covers for blanks. Provide torque reports with letter head and upload them to dashboard prior to final. 11/4/2026 |