Permit Details

Status:
Inspections
Type:
Commercial Building
Address:
331 S OLSEN AV
Address NEW:
331 S OLSEN AV
Apply Date:
03/13/2026
Applicant:
GGV Designs
Description:
THE WORK CONSISTS OF A FIRE DAMAGE REPAIR TO AN EXISTING WAREHOUSE. DAMAGE WAS DONE TO WALLS AND CEILING. STRUCTURAL DAMAGE INCLUDES CEILING JOISTS AND TJL'S LOCATED ON THE SOUTHEAST SIDE OF THE WAREHOUSE. THESE DAMAGED ELEMENTS ARE PROPOSED TO BE REPLACED LIKE FOR LIKE AS ALLOWED BY CHAPTER 4 OF THE EXISTING BUILDING CODE.

Permit Reviews

Permit Number - TC-COM-0326-00366
Permit Status: Inspections
Permit Description: THE WORK CONSISTS OF A FIRE DAMAGE REPAIR TO AN EXISTING WAREHOUSE. DAMAGE WAS DONE TO WALLS AND CEILING. STRUCTURAL DAMAGE INCLUDES CEILING JOISTS AND TJL'S LOCATED ON THE SOUTHEAST SIDE OF THE WAREHOUSE. THESE DAMAGED ELEMENTS ARE PROPOSED TO BE REPLACED LIKE FOR LIKE AS ALLOWED BY CHAPTER 4 OF THE EXISTING BUILDING CODE.
Start Date Submittal Complete Date Status  
05/11/2026 SPECIAL INSPECTION REVIEW v.1 05/12/2026 REQUIRES RESUBMIT Review Details
04/24/2026 ADMINISTRATIVE v.1 04/24/2026 REQUIRES RESUBMIT Review Details
05/12/2026 ADMINISTRATIVE v.2 05/12/2026 APPROVED Review Details
03/18/2026 COMMERCIAL REVIEW - FULL v.1 04/09/2026 REQUIRES RESUBMIT Review Details
04/20/2026 COMMERCIAL REVIEW - FULL v.2 04/24/2026 APPROVED Review Details

Outstanding Activity Conditions

Permit Number - TC-COM-0326-00366
Permit Status: Inspections
Permit Description: THE WORK CONSISTS OF A FIRE DAMAGE REPAIR TO AN EXISTING WAREHOUSE. DAMAGE WAS DONE TO WALLS AND CEILING. STRUCTURAL DAMAGE INCLUDES CEILING JOISTS AND TJL'S LOCATED ON THE SOUTHEAST SIDE OF THE WAREHOUSE. THESE DAMAGED ELEMENTS ARE PROPOSED TO BE REPLACED LIKE FOR LIKE AS ALLOWED BY CHAPTER 4 OF THE EXISTING BUILDING CODE.
Total Outstanding Activity Conditions - 5
Date Name
04/06/2026 AIR BALANCING REPORT IS REQUIRED.
04/06/2026 SPECIAL INSPECTION FOR EPOXY ANCHORS IS REQUIRED.
04/06/2026 Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building.
04/06/2026 WATER STERILIZATION REPORT IS REQUIRED.
04/06/2026 SPECIAL INSPECTION FOR WELDING IS REQUIRED.

Conditions

Permit Number - TC-COM-0326-00366
Permit Status: Inspections
Permit Description: THE WORK CONSISTS OF A FIRE DAMAGE REPAIR TO AN EXISTING WAREHOUSE. DAMAGE WAS DONE TO WALLS AND CEILING. STRUCTURAL DAMAGE INCLUDES CEILING JOISTS AND TJL'S LOCATED ON THE SOUTHEAST SIDE OF THE WAREHOUSE. THESE DAMAGED ELEMENTS ARE PROPOSED TO BE REPLACED LIKE FOR LIKE AS ALLOWED BY CHAPTER 4 OF THE EXISTING BUILDING CODE.
Date Description Comments
03/18/2026 Contractor with active Arizona Contractor's License for specified scope of work required prior to issuance of permit. Contractor must have a TDC Online account and be added to the permit as a contact.
03/18/2026 Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. For review and assessment: apply online at https://permits.pima.gov/ or contact us at sewer@pima.gov, (520) 724-9900.
04/06/2026 A Special Inspections Intermediate Certificate must be submitted and reviewed prior to issuance of this permit.

Outstanding Inspections

Permit Status: Inspections
Permit Number: TC-COM-0326-00366
Permite Description: THE WORK CONSISTS OF A FIRE DAMAGE REPAIR TO AN EXISTING WAREHOUSE. DAMAGE WAS DONE TO WALLS AND CEILING. STRUCTURAL DAMAGE INCLUDES CEILING JOISTS AND TJL'S LOCATED ON THE SOUTHEAST SIDE OF THE WAREHOUSE. THESE DAMAGED ELEMENTS ARE PROPOSED TO BE REPLACED LIKE FOR LIKE AS ALLOWED BY CHAPTER 4 OF THE EXISTING BUILDING CODE.
Total Outstanding Inspections - 1
Last Inspection Date Description Inspector Results Comments
05/14/2026 BULD - Electrical Clearance N/A Not Ready Ensure equipment is grounded with proper size ground. Provide address tag. 5/14/2026

Completed Inspections

Permit Status: Inspections
Permit Number: TC-COM-0326-00366
Permit Description: THE WORK CONSISTS OF A FIRE DAMAGE REPAIR TO AN EXISTING WAREHOUSE. DAMAGE WAS DONE TO WALLS AND CEILING. STRUCTURAL DAMAGE INCLUDES CEILING JOISTS AND TJL'S LOCATED ON THE SOUTHEAST SIDE OF THE WAREHOUSE. THESE DAMAGED ELEMENTS ARE PROPOSED TO BE REPLACED LIKE FOR LIKE AS ALLOWED BY CHAPTER 4 OF THE EXISTING BUILDING CODE.
Total Completed Inspections - 1
Date Description Inspector Results Comments
05/19/2026 BULD - Electrical Clearance Passed 05/19/2026
Approved clearance TEP RECN. No meter number, meter pulled and not on site.

Documents

File Name Document Type  
COFT - PDSD - PERMIT CARD (SSRS).PDF DOCUMENTS VIEW
IGNITE-331 S OLSEN AVE-2026-05-07_V1.PDF DOCUMENTS VIEW
2_LETTER OF RESPONSE_V1.PDF DOCUMENTS VIEW
CONS-2_DRAWINGS_IGNITE SIGN ART_V2.PDF DOCUMENTS VIEW
IGNITE FIRE REPAIR CALCS_V2.PDF DOCUMENTS VIEW