Permit Details

Status:
In Revision
Type:
Commercial Building
Address:
331 S OLSEN AV
Address NEW:
331 S OLSEN AV
Apply Date:
03/13/2026
Applicant:
GGV Designs
Description:
(REV. #2: Riser Rm Removed, Electrical Fur-out at Column, Water Heater Relocated, Bathroom Door 109 Relocated, Soffit for Duct Added, Outlets added.) FIRE DAMAGE REPAIR TO EXIST WAREHOUSE. DAMAGE TO WALLS AND CEILING. STRUCTURAL DAMAGE TO CEILING JOISTS AND TJL'S AT SOUTHEAST SIDE OF WAREHOUSE. DAMAGED ELEMENTS BE REPLACED LIKE FOR LIKE.

Permit Reviews

Permit Number - TC-COM-0326-00366
Permit Status: In revision
Permit Description: (REV. #2: Riser Rm Removed, Electrical Fur-out at Column, Water Heater Relocated, Bathroom Door 109 Relocated, Soffit for Duct Added, Outlets added.) FIRE DAMAGE REPAIR TO EXIST WAREHOUSE. DAMAGE TO WALLS AND CEILING. STRUCTURAL DAMAGE TO CEILING JOISTS AND TJL'S AT SOUTHEAST SIDE OF WAREHOUSE. DAMAGED ELEMENTS BE REPLACED LIKE FOR LIKE.
Start Date Submittal Complete Date Status  
06/22/2026 COMMERCIAL REVIEW - FULL REVISION v.1 07/14/2026 REQUIRES RESUBMIT Review Details
05/11/2026 SPECIAL INSPECTION REVIEW v.1 05/12/2026 REQUIRES RESUBMIT Review Details
07/22/2026 COMMERCIAL REVIEW - FULL REVISION v.2 N/A IN REVIEW Review Details
04/24/2026 ADMINISTRATIVE v.1 04/24/2026 REQUIRES RESUBMIT Review Details
05/12/2026 ADMINISTRATIVE v.2 05/12/2026 APPROVED Review Details
03/18/2026 COMMERCIAL REVIEW - FULL v.1 04/09/2026 REQUIRES RESUBMIT Review Details
04/20/2026 COMMERCIAL REVIEW - FULL v.2 04/24/2026 APPROVED Review Details

Outstanding Activity Conditions

Permit Number - TC-COM-0326-00366
Permit Status: In revision
Permit Description: (REV. #2: Riser Rm Removed, Electrical Fur-out at Column, Water Heater Relocated, Bathroom Door 109 Relocated, Soffit for Duct Added, Outlets added.) FIRE DAMAGE REPAIR TO EXIST WAREHOUSE. DAMAGE TO WALLS AND CEILING. STRUCTURAL DAMAGE TO CEILING JOISTS AND TJL'S AT SOUTHEAST SIDE OF WAREHOUSE. DAMAGED ELEMENTS BE REPLACED LIKE FOR LIKE.
Total Outstanding Activity Conditions - 5
Date Name
04/06/2026 AIR BALANCING REPORT IS REQUIRED.
04/06/2026 SPECIAL INSPECTION FOR EPOXY ANCHORS IS REQUIRED.
04/06/2026 Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building.
04/06/2026 WATER STERILIZATION REPORT IS REQUIRED.
04/06/2026 SPECIAL INSPECTION FOR WELDING IS REQUIRED.

Conditions

Permit Number - TC-COM-0326-00366
Permit Status: In revision
Permit Description: (REV. #2: Riser Rm Removed, Electrical Fur-out at Column, Water Heater Relocated, Bathroom Door 109 Relocated, Soffit for Duct Added, Outlets added.) FIRE DAMAGE REPAIR TO EXIST WAREHOUSE. DAMAGE TO WALLS AND CEILING. STRUCTURAL DAMAGE TO CEILING JOISTS AND TJL'S AT SOUTHEAST SIDE OF WAREHOUSE. DAMAGED ELEMENTS BE REPLACED LIKE FOR LIKE.
Date Description Comments
03/18/2026 Contractor with active Arizona Contractor's License for specified scope of work required prior to issuance of permit. Contractor must have a TDC Online account and be added to the permit as a contact.
03/18/2026 Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. For review and assessment: apply online at https://permits.pima.gov/ or contact us at sewer@pima.gov, (520) 724-9900.
04/06/2026 A Special Inspections Intermediate Certificate must be submitted and reviewed prior to issuance of this permit.

Outstanding Inspections

Permit Status: In Revision
Permit Number: TC-COM-0326-00366
Permite Description: (REV. #2: Riser Rm Removed, Electrical Fur-out at Column, Water Heater Relocated, Bathroom Door 109 Relocated, Soffit for Duct Added, Outlets added.) FIRE DAMAGE REPAIR TO EXIST WAREHOUSE. DAMAGE TO WALLS AND CEILING. STRUCTURAL DAMAGE TO CEILING JOISTS AND TJL'S AT SOUTHEAST SIDE OF WAREHOUSE. DAMAGED ELEMENTS BE REPLACED LIKE FOR LIKE.
Total Outstanding Inspections - 1
Last Inspection Date Description Inspector Results Comments
05/14/2026 BULD - Electrical Clearance N/A Not Ready Ensure equipment is grounded with proper size ground. Provide address tag. 5/14/2026

Completed Inspections

Permit Status: In Revision
Permit Number: TC-COM-0326-00366
Permit Description: (REV. #2: Riser Rm Removed, Electrical Fur-out at Column, Water Heater Relocated, Bathroom Door 109 Relocated, Soffit for Duct Added, Outlets added.) FIRE DAMAGE REPAIR TO EXIST WAREHOUSE. DAMAGE TO WALLS AND CEILING. STRUCTURAL DAMAGE TO CEILING JOISTS AND TJL'S AT SOUTHEAST SIDE OF WAREHOUSE. DAMAGED ELEMENTS BE REPLACED LIKE FOR LIKE.
Total Completed Inspections - 5
Date Description Inspector Results Comments
05/19/2026 BULD - Electrical Clearance Passed 05/19/2026
Approved clearance TEP RECN. No meter number, meter pulled and not on site.
05/28/2026 COT - LCBU - Roof Nailing Passed
06/17/2026 COT - HCPL - Rough Soil Passed 6.17.26
Plumbing under ground for bathrooms, Mop sink will be moved over due to footer location.
06/17/2026 COT - LCBU - Excavation/Rebar/Zoning Passed
06/17/2026 COT - LCBU - Preslab Passed

Documents

File Name Document Type  
COFT - PDSD - PERMIT CARD (SSRS).PDF DOCUMENTS VIEW
IGNITE-331 S OLSEN AVE-2026-05-07_V1.PDF DOCUMENTS VIEW
2_LETTER OF RESPONSE_V1.PDF DOCUMENTS VIEW
CONS-2_DRAWINGS_IGNITE SIGN ART_V2.PDF DOCUMENTS VIEW
IGNITE FIRE REPAIR CALCS_V2.PDF DOCUMENTS VIEW