Permit: TC-COM-0326-00353
Permit Details
Status:
In Revision
Type:
Commercial Building
Address:
9538 E OLD VAIL RD BLDG 1
Address NEW:
9538 E OLD VAIL RD BLDG 1
Apply Date:
03/11/2026
Applicant:
Andres Herrera
Description:
Remodel existing office space and add new exterior gate
Permit Reviews
Permit Number - TC-COM-0326-00353
Permit Status: In revision
Permit Description: Remodel existing office space and add new exterior gate
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 03/16/2026 | COMMERCIAL REVIEW - FULL v.1 | 04/08/2026 | REQUIRES RESUBMIT |
| 07/29/2026 | COMMERCIAL REVIEW - FULL REVISION v.1 | N/A | IN REVIEW |
| 05/18/2026 | RESTAMP - COMMERCIAL v.1 | 05/21/2026 | APPROVED |
| 04/21/2026 | COMMERCIAL REVIEW - FULL v.2 | 05/07/2026 | REQUIRES RESUBMIT |
| 05/08/2026 | COMMERCIAL REVIEW - FULL v.3 | 05/18/2026 | APPROVED |
Conditions
Permit Number - TC-COM-0326-00353
Permit Status: In revision
Permit Description: Remodel existing office space and add new exterior gate
| Date | Description | Comments |
|---|---|---|
| 03/16/2026 | Contractor with active Arizona Contractor's License for specified scope of work required prior to issuance of permit. Contractor must have a TDC Online account and be added to the permit as a contact. | |
| 03/16/2026 | Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. For review and assessment: apply online at https://permits.pima.gov/ or contact us at sewer@pima.gov, (520) 724-9900. |
Outstanding Inspections
Permit Status: In Revision
Permit Number: TC-COM-0326-00353
Permite Description: Remodel existing office space and add new exterior gate
Total Outstanding Inspections - 4
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/01/2026 | COT - HCEL - Electrical Above Ceiling | N/A | Partial Pass | 7-1-26: in wall electrical (intermediates) for room's 104, 114, 115, 116, 117 approved. |
| 07/10/2026 | COT - HCEL - Electrical Intermediate | N/A | Partial Pass | |
| 07/21/2026 | COT - BULD - SWG Clearance | N/A | Partial Pass | 7-21-26: drywall screw inspection at reception area approved for tape & texture. |
| 08/13/2026 | COT - HCME - Mechanical Above Ceiling | N/A | Re-inspection required | 8-13-26: open office space/106, 207,108, , 111-provide supports where flex is not on ceiling grid, 110-provide supports, add supports to flex within 2' of a bend and 4' thereafter, 107, 112-add support at elbow, 112-tear on flex & supports at 4', 103, 101, 104-flex off grid, 116-supports to flex where resting on grid, 115 & 114. Make corrections and reschedule an inspection. |
Completed Inspections
Permit Status: In Revision
Permit Number: TC-COM-0326-00353
Permit Description: Remodel existing office space and add new exterior gate
Total Completed Inspections - 2
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/06/2026 | COT - HCBU - Framing | Passed | ||
| 07/09/2026 | BULD - Electrical Clearance | Passed |