Permit Details

Status:
Approved
Type:
Commercial Building
Address NEW:
1625 N CAMPBELL AV
Apply Date:
02/09/2026
Applicant:
Aaron Koreny
Description:
THE EXISTING INPATIENT TOWER 3 OF THE BUMCT CAMPUS TO REMAIN. THE SCOPE OF WORK CONSISTS OF FINISH UPGRADES THROUGHOUT THE EXISTING MED/SURGE 3NE UNIT, WHICH INCLUDES NEW FLOORING, BASE, PAINT, WALL PROTECTION, DOORS/FRAMES/HARDWARE, ACT AND LIGHTING, AND NEW HEADWALLS IN EACH OF THE PATIENT ROOMS. SCOPE OF WORK ALSO INCLUDES THE REPLACEMENT OF AHU-7 AND ALL ASSOCIATED MEP AND STRUCTURAL WORK.

Permit Reviews

Permit Number - TC-COM-0226-00184
Permit Status: Approved
Permit Description: THE EXISTING INPATIENT TOWER 3 OF THE BUMCT CAMPUS TO REMAIN. THE SCOPE OF WORK CONSISTS OF FINISH UPGRADES THROUGHOUT THE EXISTING MED/SURGE 3NE UNIT, WHICH INCLUDES NEW FLOORING, BASE, PAINT, WALL PROTECTION, DOORS/FRAMES/HARDWARE, ACT AND LIGHTING, AND NEW HEADWALLS IN EACH OF THE PATIENT ROOMS. SCOPE OF WORK ALSO INCLUDES THE REPLACEMENT OF AHU-7 AND ALL ASSOCIATED MEP AND STRUCTURAL WORK.
Start Date Submittal Complete Date Status  
04/27/2026 SPECIAL INSPECTION REVIEW v.1 04/28/2026 REQUIRES RESUBMIT Review Details
04/06/2026 COMMERCIAL REVIEW - FULL v.3 04/17/2026 APPROVED Review Details
03/24/2026 COMMERCIAL REVIEW - FULL v.2 03/24/2026 REQUIRES RESUBMIT Review Details
04/17/2026 ADMINISTRATIVE v.1 04/17/2026 REQUIRES RESUBMIT Review Details
02/11/2026 COMMERCIAL REVIEW - FULL v.1 03/05/2026 REQUIRES RESUBMIT Review Details
06/26/2026 RESTAMP - COMMERCIAL v.1 07/01/2026 APPROVED Review Details
04/27/2026 ADMINISTRATIVE v.2 04/27/2026 APPROVED Review Details
05/13/2026 SPECIAL INSPECTION REVIEW v.2 05/14/2026 APPROVED Review Details

Outstanding Activity Conditions

Permit Number - TC-COM-0226-00184
Permit Status: Approved
Permit Description: THE EXISTING INPATIENT TOWER 3 OF THE BUMCT CAMPUS TO REMAIN. THE SCOPE OF WORK CONSISTS OF FINISH UPGRADES THROUGHOUT THE EXISTING MED/SURGE 3NE UNIT, WHICH INCLUDES NEW FLOORING, BASE, PAINT, WALL PROTECTION, DOORS/FRAMES/HARDWARE, ACT AND LIGHTING, AND NEW HEADWALLS IN EACH OF THE PATIENT ROOMS. SCOPE OF WORK ALSO INCLUDES THE REPLACEMENT OF AHU-7 AND ALL ASSOCIATED MEP AND STRUCTURAL WORK.
Total Outstanding Activity Conditions - 10
Date Name
04/16/2026 SPECIAL INSPECTION FOR BOLTS INSTALLED IN CONCRETE IS REQUIRED.
04/16/2026 SPECIAL INSPECTION FOR CONCRETE INSTALLATION IS REQUIRED.
04/16/2026 SPECIAL INSPECTION FOR EPOXY ANCHORS IS REQUIRED.
04/16/2026 SPECIAL INSPECTION FOR EXPANSION ANCHORS IS REQUIRED.
04/16/2026 SPECIAL INSPECTION FOR FOUNDATION/EXCAVATION IS REQUIRED.
04/16/2026 Masonry Inspection Report submittal review is required.
04/16/2026 SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED.
04/16/2026 Post-Tension Inspection Report is required.
04/16/2026 SPECIAL INSPECTION FOR WELDING IS REQUIRED.
04/16/2026 SPECIAL INSPECTION FOR WOOD FRAMED DIAPHRAGMS AND SHEAR WALLS IS REQUIRED.

Conditions

Permit Number - TC-COM-0226-00184
Permit Status: Approved
Permit Description: THE EXISTING INPATIENT TOWER 3 OF THE BUMCT CAMPUS TO REMAIN. THE SCOPE OF WORK CONSISTS OF FINISH UPGRADES THROUGHOUT THE EXISTING MED/SURGE 3NE UNIT, WHICH INCLUDES NEW FLOORING, BASE, PAINT, WALL PROTECTION, DOORS/FRAMES/HARDWARE, ACT AND LIGHTING, AND NEW HEADWALLS IN EACH OF THE PATIENT ROOMS. SCOPE OF WORK ALSO INCLUDES THE REPLACEMENT OF AHU-7 AND ALL ASSOCIATED MEP AND STRUCTURAL WORK.
Date Description Comments
02/11/2026 Contractor with active Arizona Contractor's License for specified scope of work required prior to issuance of permit. Contractor must have a TDC Online account and be added to the permit as a contact.
02/11/2026 Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. For review and assessment: apply online at https://permits.pima.gov/ or contact us at sewer@pima.gov, (520) 724-9900.
04/16/2026 A Special Inspections Intermediate Certificate must be submitted and reviewed prior to issuance of this permit.