Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
Inspections Complete
Type:
Commercial Building
Apply Date:
02/22/2023
Applicant:
Description:
Tenant improvements in community building, Santa Rita room, and exterior pool area. (Exterior Pool Area Improvements Removed from this permit and submitted under TC-COM-0523-01256 on 5/16/23)

Permit Reviews

Permit Number - TC-COM-0223-00687
Permit Status: Inspections complete
Permit Description: Tenant improvements in community building, Santa Rita room, and exterior pool area. (Exterior Pool Area Improvements Removed from this permit and submitted under TC-COM-0523-01256 on 5/16/23)
Start Date Submittal Complete Date Status  
06/07/2023 RESTAMP - COMMERCIAL v.1 06/07/2023 APPROVED Review Details
03/10/2023 COMMERCIAL REVIEW - FULL v.1 04/04/2023 REQUIRES RESUBMIT Review Details
05/12/2023 COMMERCIAL REVIEW - FULL v.2 05/30/2023 REQUIRES RESUBMIT Review Details
06/06/2023 COMMERCIAL REVIEW - FULL v.3 06/07/2023 APPROVED Review Details

Outstanding Activity Conditions

Permit Number - TC-COM-0223-00687
Permit Status: Inspections complete
Permit Description: Tenant improvements in community building, Santa Rita room, and exterior pool area. (Exterior Pool Area Improvements Removed from this permit and submitted under TC-COM-0523-01256 on 5/16/23)
Total Outstanding Activity Conditions - 3
Date Name
12/18/2024 AIR BALANCING REPORT IS REQUIRED.
12/18/2024 Applies to All: Deferred submittal documents must be submitted and approved prior to installation of construction elements included in deferred submittal documents.
12/18/2024 COMMISSIONING REPORT IS REQUIRED.

Conditions

Permit Number - TC-COM-0223-00687
Permit Status: Inspections complete
Permit Description: Tenant improvements in community building, Santa Rita room, and exterior pool area. (Exterior Pool Area Improvements Removed from this permit and submitted under TC-COM-0523-01256 on 5/16/23)
Date Description Comments
03/10/2023 Please contact Pima County Addressing to resolve your addressing issue related to a building number for this project. Addressing@pima.gov or 520-724-9512
03/10/2023 Contractor with active Arizona Contractor's License for specified scope of work required prior to issuance of permit.

Outstanding Inspections

Permit Status: Inspections Complete
Permit Number: TC-COM-0223-00687
Permite Description: Tenant improvements in community building, Santa Rita room, and exterior pool area. (Exterior Pool Area Improvements Removed from this permit and submitted under TC-COM-0523-01256 on 5/16/23)
Total Outstanding Inspections - 9
Last Inspection Date Description Inspector Results Comments
09/08/2023 COT - HCPL - Plumbing Intermediate N/A Not Ready Wanted UG Plumbing.
10/06/2023 COT - HCEL - Electrical Intermediate N/A Partial Pass 10/6/23: electrical intermediate passed in Santa Rita room.
10/06/2023 COT - HCME - Mechanical Intermediate N/A Partial Pass 10/6/23: mechanical intermediate passed in Santa Rita room and Gym
12/08/2023 COT - HCBU - Interior Shear Bracing N/A Partial Pass 12/8/23: Santa Rita room interior shear wall per plan ok to tape and mud.
12/08/2023 COT - LCPL - Sewer N/A Partial Pass 12/8/23: rough plumbing in pool bathroom per plan. Under test from water closet to 2-way cleanout. Pending sewer connection.
12/08/2023 COT - HCBU - Firewall/Fire Barrier/Firestop N/A Partial Pass 12/8/23: firewall per plan in Santa Rita room.
01/04/2024 COT - HCEL - Electrical Final N/A Re-inspection required Santa Rita rooms
1/4/23: unit 6101- Kitchen needs two circuits, mislabeling at sub panel, panel needs unit label, Air handler is being over amped 15Amp max, GFCI missing at laundry room, water hammer arrestor missing at dishwasher, anti-tip missing at range, GFCI missing under kitchen sink, bathroom drain not per code, lock caps at A/C condenser missing, properly secure electrical whip on exterior wall, unit number missing on exterior of unit.
Unit 6102- Kitchen needs two circuits, mislabeling at sub panel, panel needs unit label, Air handler is being over amped 15Amp max, GFCI missing at laundry room, water hammer arrestor missing at dishwasher, anti-tip missing at range, GFCI missing under kitchen sink, bathroom drain not per code, lock caps at A/C condenser missing, properly secure electrical whip on exterior wall. Unit number missing on exterior of unit.
01/04/2024 COT - HCME - Mechanical Final N/A Re-inspection required Santa Rita rooms
1/4/23: unit 6101- Kitchen needs two circuits, mislabeling at sub panel, panel needs unit label, Air handler is being over amped 15Amp max, GFCI missing at laundry room, water hammer arrestor missing at dishwasher, anti-tip missing at range, GFCI missing under kitchen sink, bathroom drain not per code, lock caps at A/C condenser missing, properly secure electrical whip on exterior wall, unit number missing on exterior of unit.
Unit 6102- Kitchen needs two circuits, mislabeling at sub panel, panel needs unit label, Air handler is being over amped 15Amp max, GFCI missing at laundry room, water hammer arrestor missing at dishwasher, anti-tip missing at range, GFCI missing under kitchen sink, bathroom drain not per code, lock caps at A/C condenser missing, properly secure electrical whip on exterior wall. Unit number missing on exterior of unit.
01/04/2024 COT - HCBU - Building Final N/A Re-inspection required Santa Rita rooms
1/4/23: unit 6101- Kitchen needs two circuits, mislabeling at sub panel, panel needs unit label, Air handler is being over amped 15Amp max, GFCI missing at laundry room, water hammer arrestor missing at dishwasher, anti-tip missing at range, GFCI missing under kitchen sink, bathroom drain not per code, lock caps at A/C condenser missing, properly secure electrical whip on exterior wall, unit number missing on exterior of unit.
Unit 6102- Kitchen needs two circuits, mislabeling at sub panel, panel needs unit label, Air handler is being over amped 15Amp max, GFCI missing at laundry room, water hammer arrestor missing at dishwasher, anti-tip missing at range, GFCI missing under kitchen sink, bathroom drain not per code, lock caps at A/C condenser missing, properly secure electrical whip on exterior wall. Unit number missing on exterior of unit.

Completed Inspections

Permit Status: Inspections Complete
Permit Number: TC-COM-0223-00687
Permit Description: Tenant improvements in community building, Santa Rita room, and exterior pool area. (Exterior Pool Area Improvements Removed from this permit and submitted under TC-COM-0523-01256 on 5/16/23)
Total Completed Inspections - 8
Date Description Inspector Results Comments
09/08/2023 COT - HCPL - Rough Soil Passed
10/06/2023 COT - HCPL - Plumbing Intermediate Passed Wanted UG Plumbing.

10/6/23: plumbing intermediate passed.
01/04/2024 TRSP - ROW - Final/Close-Out Passed
01/05/2024 COT - HCPL - Plumbing Final Passed
01/05/2024 COT - HCBU - Building Final Passed Ok to occupy housing unit.
12/30/2024 COT - FCON - Fire - Final Passed
12/30/2024 COT - FCON - Sprinkler - Final Passed
12/30/2024 ENGR Engineering Final Passed

Documents

File Name Document Type  
COFT - PDSD - PERMIT CARD.PDF DOCUMENTS VIEW
CONS-CONS-PLAN SET_PALOMAR_REVISION_2_V2_V1.PDF DOCUMENTS VIEW
PALOMAR CALCS 100 2.22.23_V2_V1.PDF DOCUMENTS VIEW
PALOMAR REMODEL SPECIFICATIONS_V2_V1.PDF DOCUMENTS VIEW