Permit: TC-COM-0223-00687
Permit Details
Apply Date:
02/22/2023
Applicant:
Description:
Tenant improvements in community building, Santa Rita room, and exterior pool area. (Exterior Pool Area Improvements Removed from this permit and submitted under TC-COM-0523-01256 on 5/16/23)
Permit Reviews
Permit Number - TC-COM-0223-00687
Permit Status: Inspections complete
Permit Description: Tenant improvements in community building, Santa Rita room, and exterior pool area. (Exterior Pool Area Improvements Removed from this permit and submitted under TC-COM-0523-01256 on 5/16/23)
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
06/07/2023 | RESTAMP - COMMERCIAL v.1 | 06/07/2023 | APPROVED |
03/10/2023 | COMMERCIAL REVIEW - FULL v.1 | 04/04/2023 | REQUIRES RESUBMIT |
05/12/2023 | COMMERCIAL REVIEW - FULL v.2 | 05/30/2023 | REQUIRES RESUBMIT |
06/06/2023 | COMMERCIAL REVIEW - FULL v.3 | 06/07/2023 | APPROVED |
Outstanding Activity Conditions
Permit Number - TC-COM-0223-00687
Permit Status: Inspections complete
Permit Description: Tenant improvements in community building, Santa Rita room, and exterior pool area. (Exterior Pool Area Improvements Removed from this permit and submitted under TC-COM-0523-01256 on 5/16/23)
Total Outstanding Activity Conditions - 3
Date | Name |
---|---|
12/18/2024 | AIR BALANCING REPORT IS REQUIRED. |
12/18/2024 | Applies to All: Deferred submittal documents must be submitted and approved prior to installation of construction elements included in deferred submittal documents. |
12/18/2024 | COMMISSIONING REPORT IS REQUIRED. |
Conditions
Permit Number - TC-COM-0223-00687
Permit Status: Inspections complete
Permit Description: Tenant improvements in community building, Santa Rita room, and exterior pool area. (Exterior Pool Area Improvements Removed from this permit and submitted under TC-COM-0523-01256 on 5/16/23)
Date | Description | Comments |
---|---|---|
03/10/2023 | Please contact Pima County Addressing to resolve your addressing issue related to a building number for this project. Addressing@pima.gov or 520-724-9512 | |
03/10/2023 | Contractor with active Arizona Contractor's License for specified scope of work required prior to issuance of permit. |
Outstanding Inspections
Permit Status: Inspections Complete
Permit Number: TC-COM-0223-00687
Permite Description: Tenant improvements in community building, Santa Rita room, and exterior pool area. (Exterior Pool Area Improvements Removed from this permit and submitted under TC-COM-0523-01256 on 5/16/23)
Total Outstanding Inspections - 9
Last Inspection Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
09/08/2023 | COT - HCPL - Plumbing Intermediate | N/A | Not Ready | Wanted UG Plumbing. |
10/06/2023 | COT - HCEL - Electrical Intermediate | N/A | Partial Pass | 10/6/23: electrical intermediate passed in Santa Rita room. |
10/06/2023 | COT - HCME - Mechanical Intermediate | N/A | Partial Pass | 10/6/23: mechanical intermediate passed in Santa Rita room and Gym |
12/08/2023 | COT - HCBU - Interior Shear Bracing | N/A | Partial Pass | 12/8/23: Santa Rita room interior shear wall per plan ok to tape and mud. |
12/08/2023 | COT - LCPL - Sewer | N/A | Partial Pass | 12/8/23: rough plumbing in pool bathroom per plan. Under test from water closet to 2-way cleanout. Pending sewer connection. |
12/08/2023 | COT - HCBU - Firewall/Fire Barrier/Firestop | N/A | Partial Pass | 12/8/23: firewall per plan in Santa Rita room. |
01/04/2024 | COT - HCEL - Electrical Final | N/A | Re-inspection required | Santa Rita rooms 1/4/23: unit 6101- Kitchen needs two circuits, mislabeling at sub panel, panel needs unit label, Air handler is being over amped 15Amp max, GFCI missing at laundry room, water hammer arrestor missing at dishwasher, anti-tip missing at range, GFCI missing under kitchen sink, bathroom drain not per code, lock caps at A/C condenser missing, properly secure electrical whip on exterior wall, unit number missing on exterior of unit. Unit 6102- Kitchen needs two circuits, mislabeling at sub panel, panel needs unit label, Air handler is being over amped 15Amp max, GFCI missing at laundry room, water hammer arrestor missing at dishwasher, anti-tip missing at range, GFCI missing under kitchen sink, bathroom drain not per code, lock caps at A/C condenser missing, properly secure electrical whip on exterior wall. Unit number missing on exterior of unit. |
01/04/2024 | COT - HCME - Mechanical Final | N/A | Re-inspection required | Santa Rita rooms 1/4/23: unit 6101- Kitchen needs two circuits, mislabeling at sub panel, panel needs unit label, Air handler is being over amped 15Amp max, GFCI missing at laundry room, water hammer arrestor missing at dishwasher, anti-tip missing at range, GFCI missing under kitchen sink, bathroom drain not per code, lock caps at A/C condenser missing, properly secure electrical whip on exterior wall, unit number missing on exterior of unit. Unit 6102- Kitchen needs two circuits, mislabeling at sub panel, panel needs unit label, Air handler is being over amped 15Amp max, GFCI missing at laundry room, water hammer arrestor missing at dishwasher, anti-tip missing at range, GFCI missing under kitchen sink, bathroom drain not per code, lock caps at A/C condenser missing, properly secure electrical whip on exterior wall. Unit number missing on exterior of unit. |
01/04/2024 | COT - HCBU - Building Final | N/A | Re-inspection required | Santa Rita rooms 1/4/23: unit 6101- Kitchen needs two circuits, mislabeling at sub panel, panel needs unit label, Air handler is being over amped 15Amp max, GFCI missing at laundry room, water hammer arrestor missing at dishwasher, anti-tip missing at range, GFCI missing under kitchen sink, bathroom drain not per code, lock caps at A/C condenser missing, properly secure electrical whip on exterior wall, unit number missing on exterior of unit. Unit 6102- Kitchen needs two circuits, mislabeling at sub panel, panel needs unit label, Air handler is being over amped 15Amp max, GFCI missing at laundry room, water hammer arrestor missing at dishwasher, anti-tip missing at range, GFCI missing under kitchen sink, bathroom drain not per code, lock caps at A/C condenser missing, properly secure electrical whip on exterior wall. Unit number missing on exterior of unit. |
Completed Inspections
Permit Status: Inspections Complete
Permit Number: TC-COM-0223-00687
Permit Description: Tenant improvements in community building, Santa Rita room, and exterior pool area. (Exterior Pool Area Improvements Removed from this permit and submitted under TC-COM-0523-01256 on 5/16/23)
Total Completed Inspections - 8
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
09/08/2023 | COT - HCPL - Rough Soil | Passed | ||
10/06/2023 | COT - HCPL - Plumbing Intermediate | Passed | Wanted UG Plumbing. 10/6/23: plumbing intermediate passed. |
|
01/04/2024 | TRSP - ROW - Final/Close-Out | Passed | ||
01/05/2024 | COT - HCPL - Plumbing Final | Passed | ||
01/05/2024 | COT - HCBU - Building Final | Passed | Ok to occupy housing unit. | |
12/30/2024 | COT - FCON - Fire - Final | Passed | ||
12/30/2024 | COT - FCON - Sprinkler - Final | Passed | ||
12/30/2024 | ENGR Engineering Final | Passed |