Inspection History Details
Inspection Status: Re-inspection required
Inspection History: COT - HCME - Mechanical Final
Permit Number - TC-COM-0223-00687
Inspection Description - COT - HCME - Mechanical Final
Inspection Status - Re-inspection required
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
01/04/2024 | COT - HCME - Mechanical Final | Re-inspection required | Santa Rita rooms 1/4/23: unit 6101- Kitchen needs two circuits, mislabeling at sub panel, panel needs unit label, Air handler is being over amped 15Amp max, GFCI missing at laundry room, water hammer arrestor missing at dishwasher, anti-tip missing at range, GFCI missing under kitchen sink, bathroom drain not per code, lock caps at A/C condenser missing, properly secure electrical whip on exterior wall, unit number missing on exterior of unit. Unit 6102- Kitchen needs two circuits, mislabeling at sub panel, panel needs unit label, Air handler is being over amped 15Amp max, GFCI missing at laundry room, water hammer arrestor missing at dishwasher, anti-tip missing at range, GFCI missing under kitchen sink, bathroom drain not per code, lock caps at A/C condenser missing, properly secure electrical whip on exterior wall. Unit number missing on exterior of unit. |