Parcel: 13727012E


Addresses:

6250 S COMMERCE CT


Inspection Status: Re-inspection required

Inspection History: COT - HCEL - Electrical Final 

Permit Number - TC-COM-0223-00687

Inspection Description - COT - HCEL - Electrical Final 

Inspection Status - Re-inspection required

Date Description Inspector Results Comments
01/04/2024 COT - HCEL - Electrical Final  Re-inspection required Santa Rita rooms
1/4/23: unit 6101- Kitchen needs two circuits, mislabeling at sub panel, panel needs unit label, Air handler is being over amped 15Amp max, GFCI missing at laundry room, water hammer arrestor missing at dishwasher, anti-tip missing at range, GFCI missing under kitchen sink, bathroom drain not per code, lock caps at A/C condenser missing, properly secure electrical whip on exterior wall, unit number missing on exterior of unit.
Unit 6102- Kitchen needs two circuits, mislabeling at sub panel, panel needs unit label, Air handler is being over amped 15Amp max, GFCI missing at laundry room, water hammer arrestor missing at dishwasher, anti-tip missing at range, GFCI missing under kitchen sink, bathroom drain not per code, lock caps at A/C condenser missing, properly secure electrical whip on exterior wall. Unit number missing on exterior of unit.