Permit: T99CM04223
Permit Details
Apply Date:
09/02/1999
Applicant:
THURESON, WAYNE EDWARD
Description:
10 MILLION GAL RESERVOIR & BOOSTER STATION 1.54000 SF (300 x 180) RESERVOIR, REINFORCED CONCRETE RETAINING WALL AND ALUMINUM ROOF SYSTEM 2.1200 SF (60 x 20) CONTROL BUILDING CMU WALLS W/ WOOD ROOF TRUSSES,PLYWOOD SHEATHING AND METAL ROOFING 3.36000 GALLON (12DIA. x 48) HYDROPNEUMATIC TANK OF STEEL
Contractors:
- BORDERLAND CONSTRUCTION COMPANY
Outstanding Activity Conditions
Permit Number - T99CM04223
Permit Status: Closed
Permit Description: 10 MILLION GAL RESERVOIR & BOOSTER STATION 1.54000 SF (300 x 180) RESERVOIR, REINFORCED CONCRETE RETAINING WALL AND ALUMINUM ROOF SYSTEM 2.1200 SF (60 x 20) CONTROL BUILDING CMU WALLS W/ WOOD ROOF TRUSSES,PLYWOOD SHEATHING AND METAL ROOFING 3.36000 GALLON (12DIA. x 48) HYDROPNEUMATIC TANK OF STEEL
Total Outstanding Activity Conditions - 5
| Date | Name |
|---|---|
| 05/01/2000 | SPECIAL INSPECTION FOR CONCRETE IS REQUIRED.. |
| 05/01/2000 | SPECIAL INSPECTION FOR REINFORCING STEEL AND/OR PRE-STRESSING TENDONS IS REQUIRED. |
| 05/01/2000 | SPECIAL INSPECTION FOR STRUCTURAL WELDING IS REQUIRED. |
| 05/01/2000 | SPECIAL INSPECTION FOR STRUCTURAL MASONRY IS REQUIRED. |
| 05/01/2000 | SPECIAL INSPECTION FOR SPECIAL GRADING, EXCAVATION AND FILLING IS REQUIRED. |
Outstanding Inspections
Permit Status: Closed
Permit Number: T99CM04223
Permite Description: 10 MILLION GAL RESERVOIR & BOOSTER STATION 1.54000 SF (300 x 180) RESERVOIR, REINFORCED CONCRETE RETAINING WALL AND ALUMINUM ROOF SYSTEM 2.1200 SF (60 x 20) CONTROL BUILDING CMU WALLS W/ WOOD ROOF TRUSSES,PLYWOOD SHEATHING AND METAL ROOFING 3.36000 GALLON (12DIA. x 48) HYDROPNEUMATIC TANK OF STEEL
Total Outstanding Inspections - 28
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| EXCAVATION/LAYOUT REBAR & ZON | N/A | Not Inspected | ||
| STEM WALL/RETAINING WALL | N/A | Not Inspected | ||
| BUILDING PRE-SLAB | N/A | Not Inspected | ||
| REINFORCED MASONRY PRE-GROUT | N/A | Not Inspected | ||
| EXT METAL CLIPS/EXT SHEATHING | N/A | Not Inspected | ||
| ROOF NAILING | N/A | Not Inspected | ||
| FRAMING | N/A | Not Inspected | ||
| SHEET ROCK NAILING | N/A | Not Inspected | ||
| BUILDING - FINAL | N/A | Not Inspected | ||
| ELECTRIC - UNDERGROUND | N/A | Not Inspected | ||
| ELECTRIC - ABOVE CEILING | N/A | Not Inspected | ||
| OUTDOOR LIGHTING FINAL | N/A | Not Inspected | ||
| PLUMBING - ROUGH, SOIL | N/A | Not Inspected | ||
| PLUMBING - INTERMEDIATE | N/A | Not Inspected | ||
| PLUMBING - ABOVE CEILING | N/A | Not Inspected | ||
| PLUMBING - GAS PRESSURE TEST | N/A | Not Inspected | ||
| SEPTIC - SYSTEM | N/A | Not Inspected | ||
| PLUMBING - PROGRESS | N/A | Not Inspected | ||
| PLUMBING - FINAL | N/A | Not Inspected | ||
| MECHANICAL - INTERMEDIATE | N/A | Not Inspected | ||
| MECHANICAL - PROGRESS | N/A | Not Inspected | ||
| MECHANICAL - FINAL | N/A | Not Inspected | ||
| BOILER UNFIRED PRESSURE VESSEL | N/A | Not Inspected | ||
| BOILER FINAL | N/A | Not Inspected | ||
| 02/07/2001 | ELECTRIC - FINAL | N/A | Denied | A/C DISCONNECT GROUND LUG HAS MILTIPULE CONDUTORS DISCONNECT NORTH SIDE USE CORRECT DISCONNECT ONE RECEPTACLE NOT 3 RECEPTACLE CORRECTLY IDENTIFY CONDUCTORS TO VOLTAGES BATHROOM ELECTRIC IN CEILING COVERED NO INSPECTION SERVICE CT CANS LOCKED NO ACCESS UFFER INSTALLED NO INSPECTION NEED GROUNDING ELECTRODE SYSTEM WELL PUMPS AND SITE LIGHTING UNDERGROUND INSTALLED NO INSPECTION LIGHT POLES INSTALLED NO INSPECTION |
| 02/07/2001 | ELECTRIC - FINAL | N/A | Denied | IVRS - Inspection 0999* UNDERGROUND COVERED NO INSPECTION FILL UNUSED OPENINGS CORRECTLY LABEL PANEL AND BREAKERS NEED BUSHINGS FOR CABLE PROTECTOIN MISSING FACE PLATE ELECTRIC IN CEILING COVERED NO INSPECTION ELEC ROOM UNDERGROUND COVERED NO INSPECTION CONTROL CENTERS ENERGIZED NO INSPECTION NEED LETTER VERIFING TORQUE SETTINGS OF SECTION ASSEMBLE LABEL PANEL AND BREAKERS CLEAN SURFACE UNDER GROUND BAR SHEET METAL SCREWS NOT ALLOWED TO ATTACH GROUND BAR ELECTRIC IN CEILING COVERED NO INSPECTION OPERATOR ROOM UNDERGROUND COVERED NO INSPECTION CEILING ELECTRIC COVERED NO INSPECTION MSSING COVER PLATE |
| 05/25/2000 | ELECTRIC - UFER | N/A | Correction Required | ADDTL COMMS - NO PLANS NO PERSON WITH KNOWLEDGE OF INSPECTION REQUEST NO UFER PLEASE RECALL |
| 06/28/2000 | ELECTRIC - INTERMEDIATE | N/A | Correction Required | ADDTL COMMS - ALREADY COVERED PLEASE UNCOVER AND RECALL |