Address Search: 12635 W MILE WIDE RD
Search
Parcel Attributes
| Parcel | 21116006A |
|---|---|
| Jurisdiction | Pima County |
| Flood Related Information | FEMA Floodplain Area |
| Pima County Data | Assessor, Recorder, Treasurer, ... |
| Parcel Map | Map |
| Parcel Attributes Issue? | |
Permits
Address: 12635 W MILE WIDE RD
Date - 08/17/2026 12:57 a.m.
Total Number Of Permits - (8)
| Permit | Status | Apply Date | Expired Date | Unit | Type | Description |
|---|---|---|---|---|---|---|
| TC-COM-1225-02182 | Submitted | 12/04/2025 | N/A | Commercial Building | This is a Tucson Water Capital Improvement Project on City Property but in the County. We are upgrading existing equipment (no new buildings). There is piping, structural and electrical elements. This is the next phase of this project. For the first 4 basins we were instructed to apply for a commercial trade permit (Permit Number: TC-COM-0823-02029). We are now working towards a similar permit for the remaining 6 basins. We would like to use the CIP Energov workflow to get review comments now (if any) while during the design phase. With questions please reach out to Tarlton Ferrin, tarlton.ferrin@tucsonaz.gov 520-837-9151 | |
| TD-DEV-1225-00300 | Submitted | 12/04/2025 | N/A | Development Package | This is a Tucson Water Capital Improvement Project on City Property but in the County. We are upgrading existing equipment (no new buildings). There is piping, structural and electrical elements. This is the next phase of this project. For the first 4 basins we were instructed to apply for a commercial trade permit (Permit Number: TC-COM-0823-02029). We are now working towards a similar permit for the remaining 6 basins. We would like to use the CIP Energov workflow to get review comments now (if any) while during the design phase. With questions please reach out to Tarlton Ferrin, tarlton.ferrin@tucsonaz.gov 520-837-9151 | |
| TC-COM-1125-02098 | Issued | 11/13/2025 | 06/28/2026 | Commercial Building | This is a Tucson Water Capital Improvement Project on City Property but in the County. We are upgrading existing equipment (no new buildings). There is piping, structural and electrical elements. This is the next phase of this project. For the first 4 basins we were instructed to apply for a commercial trade permit (Permit Number: TC-COM-0823-02029). We are now working towards a similar permit for the remaining 6 basins. We would like to use the CIP Energov workflow to get review comments now (if any) while during the design phase. With questions please reach out to Tarlton Ferrin, tarlton.ferrin@tucsonaz.gov 520-837-9151 | |
| TC-COM-0823-02029 | Issued | 08/21/2023 | 04/15/2026 | Commercial Building | Per Tucson Water request, this project is provided to address the design of improvements and control valve replacements for several of the CAVSARP recharge basin turnout facilities. Tucson Water provided the following additional direction for the scope of work: “Initially the scope of work would include improvements at four of the basins, with improvements of the remaining six basins to follow. In developing the scope of work some of the pertinent items discussed include the following: 1. Replacing the flow control valves at recharge basin RB-102, RB-103, RB-106 and RB-109 would be included in the initial set. 2. The new flow control valves would be motor operated plug valves with the appropriate size along with appropriate improvements to the existing steel piping. 3. The detailed design focuses on preparing a set of plans for use by a JOC contractor and would include Civil-Mechanical, Electrical, and Instrumentation and Control sheets. Stantec (“Designer”) is providing design services for the project. Tucson Water is the owner and the client. Tarlton Ferrin, the TW PM, was advised that PDSD permit would be waived and this Commercial Trade Permit application is needed instead. NOTE: Please note we checked "Commercial/Industrial Building" for Structure Type because a choice was required but is not fully appliable to the project. | |
| TR-UTL-0823-02308 | Void | 08/17/2023 | N/A | Right-of-Way (ROW) - Utility | Per Tucson Water request, this project is provided to address the design of improvements and control valve replacements for several of the CAVSARP recharge basin turnout facilities. Tucson Water provided the following additional direction for the scope of work: “Initially the scope of work would include improvements at four of the basins, with improvements of the remaining six basins to follow. In developing the scope of work some of the pertinent items discussed include the following: 1. Replacing the flow control valves at recharge basin RB-102, RB-103, RB-106 and RB-109 would be included in the initial set. 2. The new flow control valves would be motor operated plug valves with the appropriate size along with appropriate improvements to the existing steel piping. 3. The detailed design focuses on preparing a set of plans for use by a JOC contractor and would include Civil-Mechanical, Electrical, and Instrumentation and Control sheets. Stantec (“Designer”) is providing design services for the project. Tucson Water is the owner and the client. | |
| TD-DEV-0823-00348 | Void | 08/07/2023 | 08/06/2024 | Development Package | VOID - Application was rejected at OK's to submit and customer was told to apply for a utility permit - Per Tucson Water request, this project is provided to address the design of improvements and control valve replacements for several of the CAVSARP recharge basin turnout facilities. Tucson Water provided the following additional direction for the scope of work: “Initially the scope of work would include improvements at four of the basins, with improvements of the remaining six basins to follow. In developing the scope of work some of the pertinent items discussed include the following: 1. Replacing the flow control valves at recharge basin RB-102, RB-103, RB-106 and RB-109 would be included in the initial set. 2. The new flow control valves would be motor operated plug valves with the appropriate size along with appropriate improvements to the existing steel piping. 3. The detailed design focuses on preparing a set of plans for use by a JOC contractor and would include Civil-Mechanical, Electrical, and Instrumentation and Control sheets. Stantec (“Designer”) is providing design services for the project. Tucson Water is the owner and the client. | |
| TW-CONS-0426-0051 | Inspections | 04/16/2026 | N/A | TW CIP Planning & Engineering | PJW947, Package II, Construction-E, KE&G scope includes RB-101 and RB-105 for this permit. | |
| TW-CONS-0426-0050 | Inspections | 04/06/2026 | N/A | TW CIP Planning & Engineering | Herman's scope includes RB-104, RB-107 and RB 108 for this permit. |
Plans
Address: 12635 W MILE WIDE RD
Date - 08/17/2026 12:57 a.m.
Total Number Of Plans - (5)
| Plan Number | Status | Application Date | Exp Date | Unit | Type | Description |
|---|---|---|---|---|---|---|
| CIP-0324-00004 | In Review | 03/06/2024 | N/A | -- (CIP) Commercial Structure | ||
| CIP-0924-00033 | In Review | 09/13/2024 | N/A | -- (CIP) Commercial Structure | This is a Tucson Water Capital Improvement Project on City Property but in the County. We are upgrading existing equipment (no new buildings). There is piping, structural and electrical elements. This is the next phase of this project. For the first 4 basins we were instructed to apply for a commercial trade permit (Permit Number: TC-COM-0823-02029). We are now working towards a similar permit for the remaining 6 basins. We would like to use the CIP Energov workflow to get review comments now (if any) while during the design phase. With questions please reach out to Tarlton Ferrin, tarlton.ferrin@tucsonaz.gov 520-837-9151 | |
| TP-PRE-0523-00227 | Complete | 05/31/2023 | N/A | -- Pre-Application Conference | Per Tucson Water request, this project is provided to address the design of improvements and control valve replacements for several of the CAVSARP recharge basin turnout facilities. Tucson Water provided the following additional direction for the scope of work: “Initially the scope of work would include improvements at four of the basins, with improvements of the remaining six basins to follow. In developing the scope of work some of the pertinent items discussed include the following: 1. Replacing the flow control valves at recharge basin RB-102, RB-103, RB-106 and RB-109 would be included in the initial set. 2. The new flow control valves would be motor operated plug valves with the appropriate size along with appropriate improvements to the existing steel piping. 3. The detailed design will focus on preparing a set of plans for use by a JOC contractor and would include Civil-Mechanical, Electrical, and Instrumentation and Control sheets. Stantec (“Designer”) will provide design services for the project. Tucson Water is the owner and the client. | |
| TW-PLAN-0426-0082 | Administrative Processing | 04/03/2026 | N/A | -- TW Capital Plan | CAVSARP MOV sites 101 & 105 are nearing completion. KE&G is reporting that they will have their work finished on the Aug 19th, 2026. | |
| TW-PLAN-0526-0118 | In Review | 05/08/2026 | N/A | -- TW Capital Plan | This plan set is for RB-109 and RB-110 for the Pressure Relief Valve bypass piping and instrumentation. |