Outstanding Inspections
Permit Status: Expired
Permit Number: T99CM00556
Permite Description: SFR
Total Outstanding Inspections - 7
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| PLUMBING - YARD WTR LINE/TEST | N/A | Not Inspected | ||
| MECHANICAL - HOODS | N/A | Not Inspected | ||
| 08/01/2000 | ELECTRIC - CABLE DROP | N/A | Not ready for Inspection | |
| 12/06/2001 | BUILDING - FINAL | N/A | Denied | IVRS - Inspection 0999* |
| 12/06/2001 | ELECTRIC - FINAL | N/A | Denied | IVRS - Inspection 0999* |
| 12/06/2001 | MECHANICAL - FINAL | N/A | Denied | IVRS - Inspection 0999* |
| 12/07/2001 | PLUMBING - FINAL | N/A | Denied | 1) HEAT PUMP NOT INSTALLED 2) VENT AT WATER HEATER NOT COMPLETE 3) ADDRESS NOT POSTED 4) EXHAUST FANS NOT INSTALLED 5) PROVIDE BOXES AT BATHROOMS FOR ELECTRIC, ALSO WIRING NOT PER CODE 6) LABLE CIRCUITS AT PANEL 7) A/C UNIT NOT INSTALLED |
Completed Inspections
Permit Status: Expired
Permit Number: T99CM00556
Permit Description: SFR
Total Completed Inspections - 12
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/16/1999 | EXCAVATION/LAYOUT REBAR & ZON | RCHAVEZ | Approved | ADDTL COMMS - 12 PAHD 42 NOT INSTALLED, POUR AT YOUR OWN RISK, NEED A #4 REBAR ON TOP OF PAHD 42S WHEN INSTALLED. |
| 10/29/1999 | ROOF NAILING | MCAPISTR | Approved | ADDTL COMMS - PROGRESS OK TO PAPER ROOF. |
| 12/08/1999 | FRAMING | RAIELLO | Approved | DENIED |
| 12/27/1999 | EXT METAL CLIPS/EXT SHEATHING | RAIELLO | Approved | IVRS - Inspection 0999* |
| 12/27/1999 | EXT METAL CLIPS/EXT SHEATHING | RAIELLO | Approved | ADDTL COMMS - BIRD BLOCKS NOT COMPLETE. GABLE END TRUSS AT BACK OF HOUSE NOT PROPERLY LOADING ON PATIO COLUMN. PROVIDE 2 1/2 ABS AT EAWCH SOLE PLATE, AT REAR PATIO COLUMN. PLANS NEED TO BE REVISED TO SHOW 2 ADDED WINDOWS. WINDOW AT KITCHEN WILL REQUIRE 2 2 X 12 AT HEADER. NO APPROVED TRUSS CALCS ON SITE. CANNOT VERIFY HOLDDOWNS OR SHEARWALL NAILING. GARAGE DOOR SHEARWALLS HAVE BEEN CHANGED. REVISE PLANS TO CHECK DOOR HEADER SIZE AND SHER WALLS WITH HOLD DOWNS. STOPPED INSPECTION |
| 04/11/2000 | ELECTRIC - TEMPORARY SERVICE | RCHAVEZ | Approved | ADDTL COMMS - APPROVED - NO PERMIT CARD ON SITE. |
| 09/15/2000 | MECHANICAL - INTERMEDIATE | RAIELLO | Approved | IVRS - Inspection 0000* |
| 09/15/2000 | PLUMBING - GAS PRESSURE TEST | RAIELLO | Approved | IVRS - Inspection 0000* |
| 09/15/2000 | PLUMBING - INTERMEDIATE | RAIELLO | Approved | IVRS - Inspection 0000* |
| 09/15/2000 | ELECTRIC - INTERMEDIATE | RAIELLO | Approved | IVRS - Inspection 0000* |
| 11/20/2000 | SHEET ROCK NAILING | RAIELLO | Approved | IVRS - Inspection 0000*/SHEETROCK NOT COMPLETE RECALL WHEN COMPLETE. |
| 09/17/2001 | PLUMBING - SEWER HCS CONNECT | DBRITO | Approved | IVRS - Inspection 0000* |