Permit: T99CM00556

Parcel: 11612491A


Addresses:

1527 W SPEEDWAY BL

Inspection Status: Partial Approval

Inspection History: FRAMING

Date Description Inspector Results Comments
09/15/2000 FRAMING Partial Approval IVRS - Inspection 0000*/1. PROVIDE CONDENSATION LINE TO A/C. 2. PROVIDE #8 BARE COPPER GROUND BOND TO GAS AND COPPER WATER LINES. OK TO INSULATE RECALL 02035 AND 03035 WHEN CONPLETE.
08/01/2000 FRAMING Not ready for Inspection
07/28/2000 FRAMING Not ready for Inspection IVRS - Inspection 0000*
06/15/2000 FRAMING Denied IVRS - Inspection 0999*/SEE PREVIOUS INPECTION 6/9/00. NOTE THIS IS THE 7TH INTERMEDIATE HOMEOWNER WAS TO MEET AT 7:30AM AND DID NOT SHOW AND DID NOT ANSWER PHONE.
06/09/2000 FRAMING Denied DENIED/1. A/C HI LOW LINES ARE OUT OF WALLS. 2. PROVIDE BOND TO GAS LINE. 3. BLOCK MECHANICAL 3 SIDES. 4. PROVIDE 1" CLEARANCE FROM COMBUSTIBLES, AT FLUE PIPES. 5. PROVIDE DOUBLE STUD UNDER GIRDER TRUSS AT GARAGE. 6. MISSING ANCHOR BOLTS GARAGE ETC. 7. FIRE WALL FRAMING NOT AT 16" O.C. 8. NO CONDENSATION LINE PROVIDED. 9 NO SUPPLY OR RETURN PROVIDE TO FURNACE. 10. MECHANICAL NOT BLOCKED 3 SIDES. 11. EXHAUST DUCTS NOT SECURED. 12. NO DRYER EXHAUST DUCT 13. PLUMBING LINES NOT SECURED. 14. NO ACCESS PROVIDE TO JACCUZZI TUB AND NO GFCI CIRCUIT PROVIDE. 15. PROVIDE 2 GFCI RECEPTS AT MASTER OR CENTER A SINGLE. 16. PROVIDE 110V POWER TO GAS STOVE. 17. SHOWER DIVERTERS NOT SECURED.
05/19/2000 FRAMING Denied IVRS - Inspection 0999*/1. FRONT OF GARAGE NEED TWO ANCHOR BOLTS PER SOLE PLATE. 2. ANCHOR BOLTS WITHIN 12" OF SPLICE AT SOLE PLATE. 3. SIMPSON HANGERS AT GIRDER TRUSS FILL ALL HOLES. 4. JACK TRUSSES GARAGE MISSING H25. 5. AT HOT WATER HEATER STUDS SHOULD BE 16" O.C. FIRE WALL. 6. MECHANICAL NOT BLOCKED 3 SIDES. 7. NO FLUE VEMNTS FOR FURNACE OR HOT WATER. 8. EXHAUST FAN DUCT IS OBSTRUCTED AIR NEEDS TO ESCAPE OUTISIDE. 9. A.C. LINE OUT OF WALL 10. OVER KNOTCH DBL TOP PLATES NEED 16 GAUGE STRAPS WITH 3 LBD. NAILS EACH SIDE EACH STRAP. 11. PROVIDE BOND TO GAS AND WATER LINES. 12. COMPLETE ELECTRICAL 13. NO SWITCH WITHIN 5' OF JUCUZZI.
05/15/2000 FRAMING Denied IVRS - Inspection 0999*/1. NO PLANS OR PERMIT ON SITE. 2. MANY ITEMS FROM PRIOR INSP NOT COMPLIED WITH.
04/17/2000 FRAMING Correction Required ADDTL COMMS - DENIED - STOPPED INSPECTION. 1. PROVIDE MINIMUM 16 O.C. FRAMING AT GARAGE FIREWALL. 2. PROVIDE BOND TO GAS. 3. PROVIDE C1 STRAPS OVER KNOTCHED STUDS. LEFT SIDE OF KITCHEN WINDOW. 4. COMPLETE JACUZZI TUB AND GROUT. COMPLETE ELECTRIC WITH GFCI. PROVIDE ACCESS DOOR. 5. BLOCK MECHANICAL ON 3 SIDES. 6. COMPLETE HALL TUB AND GROUT. 7. PROVIDE TEST ON PLUMBING. 8. PROVIDE BOND TO WATER. 9. PROVIDE TEST ON GAS. 10.COMPLETE ELECTRIC GROUNDING TO METAL BOXES. 11.PROVIDE PLANS AND PERMITS.
04/17/2000 FRAMING Denied IVRS - Inspection 0999*
12/08/1999 FRAMING Denied DENIED
10/29/1999 FRAMING Correction Required ADDTL COMMS - RECALL WHEN PICK UP IS COMPLETE.
10/29/1999 FRAMING Not ready for Inspection IVRS - Inspection 0000*