Permit: T97CM04063
Permit Details
Apply Date:
12/12/1997
Applicant:
SANTA CRUZ MANUEL M & ELENA A
Description:
SFR
Completed Inspections
Permit Status: C of o
Permit Number: T97CM04063
Permit Description: SFR
Total Completed Inspections - 20
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/14/1998 | ROOF NAILING | MCAPISTR | Approved | IVRS - Inspection 0000* |
| 12/14/1998 | REINFORCED MASONRY PRE-GROUT | MCAPISTR | Approved | IVRS - Inspection 0000* |
| 08/11/1999 | EXT METAL CLIPS/EXT SHEATHING | FBRUNING | Approved | DENIED |
| 08/11/1999 | EXT METAL CLIPS/EXT SHEATHING | FBRUNING | Approved | ADDTL COMMS - 1. NEED TO ANCHOR GLB TO MASONRY WALL. 2. USE COLLAR TIES AT CONVENTIONAL FRAMING. 3. ANCHORS MISSING FOR PLATES (ENTRY). 4. STOPPED INSP. ON 01025 EXT. CLIP. 5. CONNECT TOWER TO GLB W/CLIPS. |
| 12/28/2000 | FRAMING | RCHAVEZ | Approved | IVRS - Inspection 0999*/1. PROVIDE APPROVED LAYOUT SHEET FOR TRUSSES. 2. PROVIDE DRAFTSTOP AND FIRE BLOCKS THRU OUT. 3. PROVIDE DETAILS FOR POST TO BEAM CONNECTIONS. REVISE PLAN FOR OMITTED GLU LAMS AT BACK NEED DETAILS FOR AS BUILT AT MASONRY BEARING WALL. 4. PROVIDE KITCHEN FOR OVER FRAME RAFTERS. 5. REVISE PLAN FOR CHANGES FROM FORCED AIR UNIT TO SPLIT SYSTEM IDENTIFY COMBUSTION AIR HIGH AND LOW. 6. COMPLETE ALL INTERMEDIATES PRIOR TO CALLING FOR FRAMING INSPECTION. |
| 06/05/2001 | STUCCO MESH | RCHAVEZ | Approved | IVRS - Inspection 0000*/ 1) ENTRY TOWER OK |
| 11/14/2003 | PLUMBING - GAS PRESSURE TEST | JRIVA | Approved | IVRS - Inspection 0000* |
| 11/14/2003 | PLUMBING - INTERMEDIATE | JRIVA | Approved | IVRS - Inspection 0000* |
| 12/15/2004 | MECHANICAL - INTERMEDIATE | JRIVA | Approved | IVRS - Inspection : See detailed listing on site.| 999* |
| 12/15/2004 | ELECTRIC - INTERMEDIATE | JRIVA | Approved | IVRS - Inspection : See detailed listing on site.| 999* |
| 01/27/2005 | SHEET ROCK NAILING | JRIVA | Approved | IVRS - Inspection :* APP |
| 03/02/2005 | PLUMBING - YARD WTR LINE/TEST | JRIVA | Approved | IVRS - Inspection :* |
| 03/02/2005 | ELECTRIC - CABLE DROP | JRIVA | Approved | IVRS - Inspection :* |
| 03/02/2005 | ELECTRIC - UNDERGROUND | JRIVA | Approved | IVRS - Inspection :* |
| 03/02/2005 | ELECTRIC - UFER | JRIVA | Approved | IVRS - Inspection :* |
| 03/17/2005 | MECHANICAL - FINAL | HPEDROZA | Approved | IVRS - Inspection :* |
| 03/17/2005 | PLUMBING - FINAL | HPEDROZA | Approved | IVRS - Inspection :* |
| 03/17/2005 | ELECTRIC - FINAL | HPEDROZA | Approved | IVRS - Inspection :* |
| 03/17/2005 | BUILDING - FINAL | HPEDROZA | Approved | IVRS - Inspection :* |
| 03/18/2005 | PERMIT FINALED | JWEATHER | Approved |