Inspection History Details
Inspection Status: Approved
Inspection History: BUILDING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/17/2005 | BUILDING - FINAL | Approved | IVRS - Inspection :* | |
| 03/16/2005 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) GFCI THROUGHOUT MUST TRIP WHEN TESTED 2) ELECTRICIAN ON SITE CHECKING PROBLEMS 3) JACUZZI CIRCUIT NOT INSTALLED |
|
| 03/11/2005 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) WEST SIDE EXTERIOR GFCI DOES NOT TRIP 2) FRONT GFCI NO POWER 3) KITCHEN GFCI'S WON'T TRIP OR RETEST 4) SHORT CIRCUIT AT FRDIGE OUTLET 5) NO KITCHEN SINK |
|
| 03/08/2005 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) WEST OUTSIDE GFCI OUTLET WILL NOT SET 2) SOUTH OUTSIDE AND EAST OUTSIDE GFCI OUTLET NO POWER 3) GARAGE EAST GFCI-NO POWER 4) POINTED SHEET METAL OR WOOD SCREWS CANNOT BE USED TO SECURE ELECTRIC PANEL DEAD FRONT 5) LABEL ALL CIRCUITS IN ELECTRIC PANEL 6) ELECTRIC OUTLET REQUIRED AT KITCHEN COUNTER WITHIN 24" OF SINK-COUNTER MUST BE INSTALLED |
|
| 03/07/2005 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) ITEMS FROM PRIOR INSPECTION NOT COMPLIED WITH 3, 4, 6, 10, 11, 12, 17 AND 18 2) BARE WIRES ON WEST SIDE OUTLET BOX 3) GARAGE AND OUTSIDE GFCI OUTLETS HOT WHEN TRIPPED 4) KITCHEN PENINSULA GFCI CANNOT BE UNDER AN OVERHANG GREATER THAN 6" 5) KITCHEN GFCI OUTLET REQUIRED WITHIN 24" OF LEFT SIDE OF SINK AND WITHIN 24" OF LEFT COUNTER END 6) PENINSULA GFCI WIRE MUST BE IN CONDUIT OR PHYSICALLY PROTECTED 7) KITCHEN SINK AND COUNTERS NOT INSTALLED 8) 3 BATHS NOT COMPLETE 9) NO PRIOR INSPECTION REPORT ON SITE 10) PLEASE PROVIDE INSULATION INSTALLATION CERTIFICATES |
|
| 03/02/2005 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* |