Permit: T97CM04063

Parcel: 12003184A


Addresses:

3810 S LAMAR AV

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
03/17/2005 FRAMING Approved
03/02/2005 FRAMING Partial Approval IVRS - Inspection :*
1) 3810 ADDRESS MUST BE ON HOUSE
2) BARE WIRES IN GARAGE SWITCHES AND OUTLETS
3) NO POWER TO OUTSIDE GFCI OUTLETS
4) ALL GARAGE CONVENIENCE OUTLETS MUST BE GFCI PROTECTED
5) WATER HEATER T & P LINE CANNOT USE CORRIGATED DRAIN LINE
6) OUTSIDE HOSE BIBS REQUIRE ANTI-SIPHON VALVE
7) DBL KEY DEAD BOLTS ARE NOT ALLOWED ON EXIT DOORS
8) CLEANOUTS MUST HAVE PERMANENT THREADED CAPS
9) STOOPS REQUIRED AT EXIT DOORS
10) LABEL ALL CIRCUITS IN ELECTRIC PANEL
11) SECURE DEAD FRONT ON ELECTRIC PANEL
12) ALL MULTI WIRE CIRCUITS MUST BE TIED TO TRIP TOGETHER
13) OUTSIDE LIGHTS NOT INSTALLED
14) PROVIDE 36" X 36" CLEAR AREA IN FRONT OF ELECTRIC PANEL
15) SMOKE DETECTORS NOT INSTALLED
16) LAUNDRY ROOM NOT COMPLETE
17) HALL BATH NOT COMPLETE
18) S.E. BATH NOT COMPLETE
01/11/2005 FRAMING Partial Approval IVRS - Inspection :*
1) OK TO INSULATE AND DRYWALL
2) CALL FOR INSPECTION OF ENTRY ARCH
12/15/2004 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) HAVE MECHANICAL PLAN REVISION APPROVED BY CITY OF TUCSON
2) GARAGE ELECTRIC OUTLETS MUST BE 18" ABOVE FLOOR
3) NAIL PROTECT WIRE ABOVE BR2
4) WIRE SITTING ROOM OUTLET
5) CAP ABANDONED DIRTY ?
6) WIRE CLOSET CAN LITE
7) NAIL PROTECT PLUMBING AT WET BAR AND REC ROOM
8) MOVE GAS BOND OUTSIDE
9) FAN BOX CANNOT USE DRYWALL SCREWS
10) PROVIDE GAS LINE TO ROOF
11) FIREBLOCK LAUNDRY VENT
12/28/2000 FRAMING Denied IVRS - Inspection 0999*/1. PROVIDE APPROVED LAYOUT SHEET FOR TRUSSES. 2. PROVIDE DRAFTSTOP AND FIRE BLOCKS THRU OUT. 3. PROVIDE DETAILS FOR POST TO BEAM CONNECTIONS. REVISE PLAN FOR OMITTED GLU LAMS AT BACK NEED DETAILS FOR AS BUILT AT MASONRY BEARING WALL. 4. PROVIDE KITCHEN FOR OVER FRAME RAFTERS. 5. REVISE PLAN FOR CHANGES FROM FORCED AIR UNIT TO SPLIT SYSTEM IDENTIFY COMBUSTION AIR HIGH AND LOW. 6. COMPLETE ALL INTERMEDIATES PRIOR TO CALLING FOR FRAMING INSPECTION.
08/03/2000 FRAMING Denied NO MESSAGE GATES LOCKED NO ACCESS.