Permit: T22CM06299
Permit Details
Status:
Complete
Type:
Residential Building - One or Two Family
Address:
2009 W SAN JUAN TR
Address NEW:
2009 W SAN JUAN TR
Apply Date:
08/17/2022
Applicant:
Gilbert Catalan
Description:
R-Bathroom Addition
Permit Reviews
Permit Number - T22CM06299
Permit Status: Complete
Permit Description: R-Bathroom Addition
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 08/17/2022 | RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO | 09/12/2022 | COMPLETED |
| 01/23/2024 | RESIDENTIAL NEW DWELLING v.2 | 02/06/2024 | APPROVED |
| 10/30/2023 | RESIDENTIAL NEW DWELLING v.1 | 10/30/2023 | REQUIRES RESUBMIT |
Conditions
Permit Number - T22CM06299
Permit Status: Complete
Permit Description: R-Bathroom Addition
| Date | Description | Comments |
|---|---|---|
| 02/06/2024 | The Contractor you have added to your permit cannot be verified. Please contact staff to have the ROC number added to the account. | |
| 02/06/2024 | Contractor with active Arizona Contractor's License for specified scope of work, or a signed Owner Builder Affidavit https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/permits/residential-permits/pdsd_owner_builder_affidavit_081623.pdf, is required prior to issuance of permit. Contractor or Owner must have a TDC Online account and be added to the permit as the correct contact type https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/tdc-faq/new-pdfs/adding-additional-contacts.pdf. If you are providing an Owner Builder Affidavit, the owner MUST be attached as a contact on the permit. |
Outstanding Inspections
Permit Status: Complete
Permit Number: T22CM06299
Permite Description: R-Bathroom Addition
Total Outstanding Inspections - 2
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/22/2024 | COT - RSBU - Masonry Pregrout | N/A | Partial Pass | |
| 04/12/2024 | COT - RSBU - Excavation/Rebar/Zoning | N/A | Partial Pass | 4/12/24: CMU footers for stem wall per plan ok to proceed. |
Completed Inspections
Permit Status: Complete
Permit Number: T22CM06299
Permit Description: R-Bathroom Addition
Total Completed Inspections - 12
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/23/2024 | COT - RSBU - Masonry Pregrout | Passed | ||
| 04/23/2024 | COT - RSBU - Stem Wall/Retaining Wall | Passed | ||
| 04/23/2024 | COT - RSPL - Rough Soil | Passed | ||
| 04/24/2024 | COT - RSBU - Preslab | Passed | ||
| 05/09/2024 | COT - RSBU - Roof Nailing | Passed | Ok to,dry in roof system. | |
| 05/09/2024 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Passed | Ok to cover exterior walls. | |
| 05/28/2024 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Passed | 5/22/24: ground/bond bushing required at raceway at (main panel and sub panel), grounds and neutrals need to be separate at sub-panel, seal all penetrations through vapor barrier, seal all penetrations through top plate, fire blocking required along perimeter of addition at top plate, copper piping outside of thermal envelope must be insulated, copper in contact with stucco must be wrapped for protection against corrosion, 5/28/24: corrections made ok to proceed. |
|
| 08/07/2024 | COT - RSBU - Excavation/Rebar/Zoning | Passed | ||
| 08/07/2024 | COT - RSME - Mechanical Final | Passed | ||
| 08/07/2024 | COT - RSPL - Plumbing Final | Passed | ||
| 08/12/2024 | RSBU - Building Final | Passed | 8/12/2024 corrections were made. | |
| 08/12/2024 | COT - RSEL - Electrical Final | Passed | 8/12/2024 corrections were made. |