Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO
Permit Number - T22CM06299
Review Name: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 08/23/2022 | PAUL CAMARENA | ZONING | REVIEW | Reqs Change | FROM: Paul Camarena PDSD Zoning Review Section PROJECT: T22CM06299 Addition 2009 W SAN JUAN TR Zoning R-1 TRANSMITTAL DATE:?August 18, 2022 COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed. 1.COMMENT: Provide permit documentation for the sheds or include them in the plan set. Please include height, square footage, and setback dimensions. 2.COMMENT: Draw dimension and label the height of the new structure measured from design grade to top of wall. 3.COMMENT: After researching PRO there are records for an expired addition T11CM03876, there are outstanding inspections. A "Finals only permit" will have to be obtained and the permit referenced above must be finalized prior to zoning approval of this permit. 4.COMMENT: Provide the cut and fill amounts in cubic yards. If you have any questions about this transmittal, Contact Paul Camarena at (520)837-4986 or by email Paul.Camarena@tucsonaz.gov |
| 08/23/2022 | SSHIELD1 | ENGINEERING | REVIEW | Passed | |
| 08/29/2022 | AWARNER1 | NPPO | REVIEW | Approved | |
| 09/10/2022 | SAFEBUILT | 2ND PARTY REVIEW | REVIEW | Reqs Change | Activity Number: T22CM06299 GENERAL: Provide written responses to all review comments. Provide a complete plan set. Provide additional documents as requested by review staff. STRUCTURAL REVIEW COMMENTS: Denied 1. structural comments may be required once the plans have been revised, See building comments. BUILDING REVIEW COMMENTS: Denied 1. Every room used for sleeping (bedroom) shall have not less than one operational emergency escape window installed IRC R310.1. The existing bedroom must have an egress window installed; the occupants cannot go through another room to escape even if there is no locking hardware on the door. The plan will need to be revised to meet this requirement., additional comments may be required once submitted. 2. Clarify the scope of work for the remodel of the existing bathroom on the plans. 3. Indicate the insulation requirements for the new walls and ceiling on the plans. A minimum of R30 is required for the ceiling (per exception) where as R13 is required in the walls. 2018 IECC table R402. MECHANICAL REVIEW COMMENTS: Denied 1. Indicate how the new bathroom will be heated, the note indicates no HVAC will be provided. 2018 IRC R303.10 as amended. ELECTRICAL REVIEW COMMENTS Denied 1. Provide an electrical panel schedule for the project showing the new bathroom branch circuits. 2. Indicate on the drawings that smoke detectors will be installed in the existing house if not already there. Smoke detectors shall be installed in each sleeping room, outside of each sleeping room in the immediate vicinity of the bedrooms. 2018 IRC R314.2. All smoke detectors shall receive their primary power from the building wiring with a battery backup and shall be interconnected so that the actuation of one alarm will activate all. 2018 IRC R314.4. 3. Indicate on the drawings that carbon monoxide detectors will be installed in the existing house. Carbon monoxide detectors shall be installed outside of each sleeping area in the immediate vicinity of the bedrooms. 2018 IRC R315.3. Carbon monoxide devices shall receive their primary power from the building wiring with a battery backup and shall be interconnected so that the actuation of one alarm will activate all. 2018 IRC R314.4. Smoke detectors and carbon monoxide alarms may be combined. PLUMBING REVIEW COMMENTS: Approved If you require additional clarification regarding these comments, please contact Doris Benoit at doris.benoit@tucsonaz.gov |