Permit: T22CM06227
Permit Details
Status:
Complete
Type:
Residential Building - One or Two Family
Address:
1069 E IRWIN PL
Address NEW:
1069 E IRWIN PL
Apply Date:
08/15/2022
Applicant:
Description:
SFR IRWI678 T22-M0053
Permit Reviews
Permit Number - T22CM06227
Permit Status: Complete
Permit Description: SFR IRWI678 T22-M0053
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 07/01/2022 | RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO | 08/17/2022 | COMPLETED |
| 02/02/2023 | RESIDENTIAL NEW DWELLING v.2 | 02/08/2023 | APPROVED |
| 03/25/2024 | BUILDING DEFERRED SUBMITTAL REVIEW v.1 | 03/28/2024 | APPROVED |
| 04/16/2024 | BUILDING DEFERRED SUBMITTAL REVIEW v.3 | 04/17/2024 | APPROVED |
| 12/29/2022 | RESIDENTIAL NEW DWELLING v.1 | 01/27/2023 | REQUIRES RESUBMIT |
| 04/11/2024 | BUILDING DEFERRED SUBMITTAL REVIEW v.2 | 04/12/2024 | REQUIRES RESUBMIT |
| 04/09/2024 | BUILDING DEFERRED SUBMITTAL REVIEW v.1 | 04/09/2024 | REQUIRES RESUBMIT |
Conditions
Permit Number - T22CM06227
Permit Status: Complete
Permit Description: SFR IRWI678 T22-M0053
| Date | Description | Comments |
|---|---|---|
| 08/15/2022 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. | |
| 08/15/2022 | ROOF TRUSSES MUST BE APPROVED PRIOR TO FRAMING INSPECTION (P2I) | |
| 04/05/2024 | SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED. | |
| 04/12/2024 | Post-Tension Inspection Report is required. | |
| 04/12/2024 | Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. Contact sewer@pima.gov for review and assessment. |
Outstanding Inspections
Permit Status: Complete
Permit Number: T22CM06227
Permite Description: SFR IRWI678 T22-M0053
Total Outstanding Inspections - 3
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/15/2022 | COT - LCPL - Plumbing Intermediate | N/A | Canceled | {Activity date: 08/15/2022; Status: Not Applicable; Inspector: KEN; Comment: Entered by KKARSEN1 - } |
| 08/15/2022 | RSME - Mechanical Progress | N/A | Canceled | {Activity date: 08/15/2022; Status: Not Applicable; Inspector: KEN; Comment: Entered by KKARSEN1 - } |
| 05/08/2023 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | N/A | Partial Pass | 4-28-23: Headroom is too low. OK to proceed elsewhere; can look at corrections at Intermediate. |
Completed Inspections
Permit Status: Complete
Permit Number: T22CM06227
Permit Description: SFR IRWI678 T22-M0053
Total Completed Inspections - 18
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/15/2023 | COT - RSPL - Sewer | Passed | Waste piping is connected to the City of Tucson sewer line and under a water test with no leaks. | |
| 03/15/2023 | COT - RSPL - Rough Soil | Passed | Underground plumbing pipes are under water test and holding. Okay to backfill trenches. | |
| 03/30/2023 | COT - RSBU - Excavation/Rebar/Zoning | Passed | ||
| 03/30/2023 | COT - RSBU - Preslab | Passed | ||
| 04/28/2023 | COT - RSBU - Roof Nailing | Passed | ||
| 06/23/2023 | COT - RSEL - Grounding/Bonding | Passed | Electrical panel is properly connected to the ufer rebar ground and to the exterior water pipe. | |
| 06/23/2023 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Passed | Framing, electrical, mechanical, and plumbing rough-in is complete. Okay to insulate, drywall, tape, and texture walls. | |
| 06/23/2023 | BULD - Electrical Clearance | Passed | Electrical panel is properly connected to the ufer rebar ground and to the exterior water pipe. okay to energize panel. | |
| 12/19/2023 | COT - RSEL - Electrical Underground | Passed | ||
| 03/08/2024 | COT - RSME - Mechanical Final | Passed | ||
| 03/08/2024 | COT - RSPL - Plumbing Final | Passed | ||
| 03/08/2024 | COT - BULD - SWG Clearance | Passed | n/a | |
| 03/08/2024 | COT - RSPL - Gas Pressure Test | Passed | ||
| 03/08/2024 | COT - RSBU - Firewall/Fire Barrier/Firestop | Passed | ||
| 03/20/2024 | COT - RSPL - Yard Water Line | Passed | ||
| 03/20/2024 | COT - RSEL - Outdoor Lighting | Passed | ||
| 03/20/2024 | COT - RSEL - Electrical Final | Passed | ||
| 03/20/2024 | RSBU - Building Final | Passed |