Permit Details

Status:
Complete
Type:
Residential Building - One or Two Family
Address:
1085 E IRWIN PL
Address NEW:
1085 E IRWIN PL
Apply Date:
08/15/2022
Applicant:
Description:
SFR IRWI678 T22-M0053

Permit Reviews

Permit Number - T22CM06224
Permit Status: Complete
Permit Description: SFR IRWI678 T22-M0053
Start Date Submittal Complete Date Status  
07/01/2022 RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO 08/17/2022 COMPLETED Review Details
04/17/2024 BUILDING DEFERRED SUBMITTAL REVIEW v.2 04/17/2024 APPROVED Review Details
04/11/2024 BUILDING DEFERRED SUBMITTAL REVIEW v.1 04/12/2024 REQUIRES RESUBMIT Review Details
02/02/2023 RESIDENTIAL NEW DWELLING v.2 02/07/2023 APPROVED Review Details
03/25/2024 BUILDING DEFERRED SUBMITTAL REVIEW v.1 03/27/2024 APPROVED Review Details
12/29/2022 RESIDENTIAL NEW DWELLING v.1 01/27/2023 REQUIRES RESUBMIT Review Details

Conditions

Permit Number - T22CM06224
Permit Status: Complete
Permit Description: SFR IRWI678 T22-M0053
Date Description Comments
08/15/2022 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.
08/15/2022 ROOF TRUSSES MUST BE APPROVED PRIOR TO FRAMING INSPECTION (P2I)
04/05/2024 SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED.
04/12/2024 Post-Tension Inspection Report is required.
04/12/2024 Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. Contact sewer@pima.gov for review and assessment.

Outstanding Inspections

Permit Status: Complete
Permit Number: T22CM06224
Permite Description: SFR IRWI678 T22-M0053
Total Outstanding Inspections - 2
Last Inspection Date Description Inspector Results Comments
08/15/2022 COT - LCPL - Plumbing Intermediate N/A Canceled {Activity date: 08/15/2022; Status: Not Applicable; Inspector: KEN; Comment: Entered by KKARSEN1 - }
08/15/2022 RSME - Mechanical Progress N/A Canceled {Activity date: 08/15/2022; Status: Not Applicable; Inspector: KEN; Comment: Entered by KKARSEN1 - }

Completed Inspections

Permit Status: Complete
Permit Number: T22CM06224
Permit Description: SFR IRWI678 T22-M0053
Total Completed Inspections - 19
Date Description Inspector Results Comments
03/15/2023 COT - RSPL - Sewer Passed Waste piping is connected to the City of Tucson sewer line and under a water test with no leaks.
03/15/2023 COT - RSPL - Rough Soil Passed Underground plumbing pipes are under water test and holding. Okay to backfill trenches.
03/30/2023 COT - RSBU - Excavation/Rebar/Zoning Passed
03/30/2023 COT - RSBU - Preslab Passed
05/17/2023 COT - RSBU - Roof Nailing Passed
05/19/2023 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Passed Corrections were made. 5/19/2023
08/24/2023 COT - RSEL - Grounding/Bonding Passed
09/20/2023 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Passed 9/20/23: Contractor has sealed torn vapor barrier in garage. Fire foamed all penetration that are in the top plate. Nail plates have been installed where needed. Receptacle has been installed at Bath #1 sink location. Shower pans and bath tub is installed and under water pressure test. Okay to install drywall, tape, texture and paint interior walls and ceilings.
12/19/2023 COT - RSEL - Electrical Underground Passed
12/19/2023 BULD - Electrical Clearance Passed Clearance for TEP ECO. 12/19/2023
03/08/2024 COT - RSPL - Plumbing Final Passed
03/08/2024 COT - RSBU - Firewall/Fire Barrier/Firestop Passed
03/08/2024 COT - BULD - SWG Clearance Passed
03/08/2024 COT - RSME - Mechanical Final Passed
03/08/2024 COT - RSPL - Gas Pressure Test Passed
03/20/2024 COT - RSPL - Yard Water Line Passed
03/20/2024 COT - RSEL - Outdoor Lighting Passed
03/20/2024 COT - RSEL - Electrical Final Passed Corrections were made. 3/20/2024
03/20/2024 RSBU - Building Final Passed Corrections were made. 3/20/2024

Documents

File Name Document Type  
COFO_FINALCOFO_RESIDENTIAL.PDF DOCUMENTS VIEW
POST TENSION CERTIFICATE - UPDATED 2-2024-04-15_V2.PDF DOCUMENTS VIEW
1085 E IRWIN LAYOUT_V1.PDF DOCUMENTS VIEW
COFT - PDSD - PERMIT CARD.PDF DOCUMENTS VIEW
R71832727.J2202545A_V1.PDF DOCUMENTS VIEW
R76028932.J2202545A_V1.PDF DOCUMENTS VIEW
COFT - PDSD - PERMIT CARD.PDF DOCUMENTS VIEW
1085 DDO-22-72 DECISION_V1.PDF DOCUMENTS VIEW
CONS-CONS-D3_V1_V1.PDF DOCUMENTS VIEW
LOT 8 - A0-IRWIN LOT 8- SITE PLAN_V1.PDF DOCUMENTS VIEW