Inspection Status: Not Ready
Inspection History: COT - RSBU - Exterior/Interior Clips/Sheathing/Framing
| Date |
Description |
Inspector |
Results |
Comments |
| 05/17/2023 |
COT - RSBU - Exterior/Interior Clips/Sheathing/Framing |
|
Not Ready |
Not ready. Missing anchor bolts behind shear walls according to the shear wall schedule. Add anchor bolts to those that are out of the center third of the bottom plate. Nail every 16" at bottom plate second floor perimeter. Loose shear walls. 5/17/2023 |
| 05/19/2023 |
COT - RSBU - Exterior/Interior Clips/Sheathing/Framing |
|
Passed |
Corrections were made. 5/19/2023 |