Permit Details

Status:
Inspections
Type:
Residential Building - One or Two Family
Address:
2316 E HELEN ST
Address NEW:
2316 E HELEN ST
Apply Date:
08/02/2022
Applicant:
Matt Smith
Description:
R-Master Suite and Dining Room Addition -341 sf

Permit Reviews

Permit Number - T22CM05873
Permit Status: Inspections
Permit Description: R-Master Suite and Dining Room Addition -341 sf
Start Date Submittal Complete Date Status  
08/02/2022 RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO 08/22/2022 COMPLETED Review Details
03/29/2023 RESTAMP - RESIDENTIAL v.1 03/30/2023 APPROVED Review Details
02/10/2023 RESIDENTIAL NEW DWELLING v.1 03/03/2023 REQUIRES RESUBMIT Review Details
03/14/2023 RESIDENTIAL NEW DWELLING v.2 03/29/2023 APPROVED Review Details

Conditions

Permit Number - T22CM05873
Permit Status: Inspections
Permit Description: R-Master Suite and Dining Room Addition -341 sf
Date Description Comments
03/29/2023 Contractor's active Arizona Contractor's License number for specified scope of work required prior to issuance of permit., or a signed Owner Builder Affidavit https://www.tucsonaz.gov/files/integrated-planning/PDSD/PDSD_Owner_Builder_Affidavit.pdf, is required prior to issuance of permit.

Outstanding Inspections

Permit Status: Inspections
Permit Number: T22CM05873
Permite Description: R-Master Suite and Dining Room Addition -341 sf
Total Outstanding Inspections - 3
Last Inspection Date Description Inspector Results Comments
03/17/2025 RSBU - Building Final N/A Re-inspection required 17 Mar 25
1. Outdoor receptacle needs to be Weather rated; will have a "WR" stamped on the front. The outlet in bathroom is WR rated maybe switch that one out with the exterior.
2. The circuits are not labeled in the main pain.
3. Mini split calls for 15 amp max CB.
03/17/2025 COT - RSEL - Electrical Final N/A Re-inspection required 17 Mar 25
1. Outdoor receptacle needs to be Weather rated; will have a "WR" stamped on the front. The outlet in bathroom is WR rated maybe switch that one out with the exterior.
2. The circuits are not labeled in the main pain.
3. Mini split calls for 15 amp max CB.
03/17/2025 COT - RSME - Mechanical Final N/A Re-inspection required 17 Mar 25
1. Outdoor receptacle needs to be Weather rated; will have a "WR" stamped on the front. The outlet in bathroom is WR rated maybe switch that one out with the exterior.
2. The circuits are not labeled in the main pain.
3. Mini split calls for 15 amp max CB.

Completed Inspections

Permit Status: Inspections
Permit Number: T22CM05873
Permit Description: R-Master Suite and Dining Room Addition -341 sf
Total Completed Inspections - 8
Date Description Inspector Results Comments
05/17/2023 COT - RSPL - Rough Soil Passed
05/17/2023 COT - RSPL - Sewer Passed
06/21/2023 COT - RSBU - Excavation/Rebar/Zoning Passed Rebar reinforcement is installed per plans. Footing are properly dug 12" below grade. Okay to pour concrete footings and slab on grade.
06/21/2023 COT - RSBU - Preslab Passed Rebar reinforcement is installed per plans. Footing are properly dug 12" below grade. Okay to pour concrete footings and slab on grade.
08/10/2023 BULD - Electrical Clearance Passed
02/02/2024 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Passed Electrical and plumbing rough-in is complete, mini-split unit is installed, and all top plate penetrations are sealed with foam. Okay to proceed with installation of insulation and drywall.
03/17/2025 COT - RSEL - Outdoor Lighting Passed
03/17/2025 COT - RSPL - Plumbing Final Passed

Documents

File Name Document Type  
COFT - PDSD - PERMIT CARD.PDF DOCUMENTS VIEW
PDSD_OWNER_BUILDER_AFFIDAVIT_V1.PDF DOCUMENTS VIEW
CONS-SMITH_2316 E HELEN ST_PERMIT SUBMITTAL.R.2_V2.PDF DOCUMENTS VIEW