Permit Details

Status:
Complete
Type:
Commercial Building
Address NEW:
1137 N DODGE BL BLDG 1
Apply Date:
06/20/2022
Applicant:
Hank Krzysik
Description:
New 1,154 sq. ft. addition to existing structure

Permit Reviews

Permit Number - T22CM04613
Permit Status: Complete
Permit Description: New 1,154 sq. ft. addition to existing structure
Start Date Submittal Complete Date Status  
06/20/2022 COMMERCIAL - BLDG/FIRE/ZONING/ENG 08/24/2022 COMPLETED Review Details
09/15/2022 RESUBMITTAL 10/04/2022 COMPLETED Review Details
02/14/2023 BUILDING DEFERRED SUBMITTAL REVIEW v.1 02/16/2023 APPROVED Review Details
07/12/2023 BUILDING DEFERRED SUBMITTAL REVIEW v.1 07/13/2023 APPROVED Review Details
12/30/2022 COMMERCIAL REVIEW - FULL v.1 01/05/2023 APPROVED Review Details
08/04/2023 BUILDING DEFERRED SUBMITTAL REVIEW v.1 08/07/2023 APPROVED Review Details
06/28/2023 BUILDING DEFERRED SUBMITTAL REVIEW v.1 06/29/2023 APPROVED Review Details

Conditions

Permit Number - T22CM04613
Permit Status: Complete
Permit Description: New 1,154 sq. ft. addition to existing structure
Date Description Comments
09/26/2022 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.
09/26/2022 SPECIAL INSPECTION FOR CONCRETE IS REQUIRED..
09/26/2022 SPECIAL INSPECTION FOR STRUCTURAL MASONRY IS REQUIRED.
09/26/2022 SPECIAL INSPECTION FOR SITE PREPARATION IS REQUIRED.
09/26/2022 SPECIAL INSPECTION FOR FOUNDATION/EXCAVATION IS REQUIRED.
09/26/2022 SPECIAL INSPECTION FOR FIELD WELDING IS REQUIRED.
09/26/2022 SPECIAL INSPECTION IS REQUIRED FOR - AIR BALANCE REPORT REQUIRED PRIOR TO FINAL INSPECTION.
02/16/2023 Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building.

Outstanding Inspections

Permit Status: Complete
Permit Number: T22CM04613
Permite Description: New 1,154 sq. ft. addition to existing structure
Total Outstanding Inspections - 3
Last Inspection Date Description Inspector Results Comments
06/29/2023 COT - FCON - Fire - Final N/A Partial Pass Fire extinguisher needs to be hung on wall, Em light needs to be repaired.
04/13/2023 COT - LCBU - Building Final N/A Partial Pass 4-13-23: Intermediate.
06/29/2023 COT - LCEL - Electrical Final N/A Re-inspection required 6/29/23: label all breakers in main panel, install WR receptacles at all exterior locations.

Completed Inspections

Permit Status: Complete
Permit Number: T22CM04613
Permit Description: New 1,154 sq. ft. addition to existing structure
Total Completed Inspections - 11
Date Description Inspector Results Comments
02/01/2023 COT - LCBU - Preslab Passed
02/14/2023 COT - HCBU - Masonry Pregrout Passed
03/17/2023 COT - LCBU - Building Progress Passed Building framing for shear walls is complete. Roof joists are installed and plywood properly nailed off. Okay to apply roofing and stucco lath.
04/25/2023 BULD - Electrical Clearance Passed Approved service upgrade, INCR Clearance to TEP is required for the electrical cutover (Note - 2 existing service meters to be combined into 1)
06/29/2023 COT - LCME - Mechanical Final Passed
06/29/2023 COT - LCPL - Plumbing Final Passed
06/29/2023 ENGR Engineering Final Passed
06/28/2023 TRSP - ROW - Notice of Completion Passed
07/12/2023 COT - FCON - Fire - Final Passed
07/20/2023 COT - LCBU - Building Final Passed Not ready for final inspection. Needed a framing and roofing inspection which is under building progress inspection.

4-13-23: Intermediate.

6/29/23: install hard surface landing outside the south exit door (44" in direction of travel X width of door opening). Lock sliding door on south wall and post a sign not for use. Install 12" high street address numbers on the structure at street side.

4-21-23: Lath.

7/20/23: OK to issue CofO.
07/20/2023 COT - LCEL - Electrical Final Passed

Documents

File Name Document Type  
COFO_FINALCOFO_COMMERCIAL.PDF DOCUMENTS VIEW
T22CM04613 SPECIAL INSPECTION CERTIFICATE-2023-08-03_V1.PDF DOCUMENTS VIEW
T22CM04613 TAB REPORT_V1.PDF DOCUMENTS VIEW
WMG LEARNING CENTER STERILIZATION LAB REPORT 6-7-23-2023-06-27_V1.PDF DOCUMENTS VIEW
T22CM04613 WMG LEARNING CENTER TRUSS CALCS_V1.PDF DOCUMENTS VIEW
T22CM04613 WMG LEARNING CENTER TRUSS LAYOUT_V1.PDF DOCUMENTS VIEW
T22CM04613 WMG LEARNING CENTER TRUSS CALCS_V1.PDF DOCUMENTS VIEW
T22CM04613 WMG LEARNING CENTER TRUSS LAYOUT_V1.PDF DOCUMENTS VIEW
COFT - PDSD - PERMIT CARD.PDF DOCUMENTS VIEW
CONS-WSMG FINAL BLDG MERGED PDF (12-29-2022)_V1.PDF DOCUMENTS VIEW