Permit: T22CM04426
Permit Details
Status:
Issued
Type:
Commercial Building
Address:
4110 S HOUGHTON RD
Address NEW:
4110 S HOUGHTON RD
Apply Date:
06/14/2022
Applicant:
Brian Cummmings
Description:
Interior remodel and new porch additions
Permit Reviews
Permit Number - T22CM04426
Permit Status: Issued
Permit Description: Interior remodel and new porch additions
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 06/14/2022 | COMMERCIAL - BLDG/FIRE/ZONING/ENG | 08/09/2022 | COMPLETED |
| 08/16/2022 | RESUBMITTAL | 09/16/2022 | COMPLETED |
| 02/09/2024 | COMMERCIAL REVIEW - FULL v.1 | 02/13/2024 | APPROVED |
| 06/12/2023 | COMMERCIAL REVIEW - FULL v.1 | 07/11/2023 | APPROVED |
| 07/11/2023 | RESTAMP - COMMERCIAL v.1 | 07/11/2023 | APPROVED |
| 05/06/2025 | COMMERCIAL REVIEW - FULL REVISION v.1 | 05/12/2025 | APPROVED |
Outstanding Activity Conditions
Permit Number - T22CM04426
Permit Status: Issued
Permit Description: Interior remodel and new porch additions
Total Outstanding Activity Conditions - 11
| Date | Name |
|---|---|
| 03/15/2024 | AIR BALANCING REPORT IS REQUIRED. |
| 03/15/2024 | SPECIAL INSPECTION FOR BOLTS INSTALLED IN CONCRETE IS REQUIRED. |
| 03/15/2024 | SPECIAL INSPECTION FOR EPOXY ANCHORS IS REQUIRED. |
| 03/15/2024 | SPECIAL INSPECTION FOR EXPANSION ANCHORS IS REQUIRED. |
| 03/15/2024 | SPECIAL INSPECTION FOR FIELD WELDING IS REQUIRED. |
| 03/15/2024 | This project requires the completion of a Fire Construction Permit PRIOR TO FINALING this permit. |
| 03/15/2024 | SPECIAL INSPECTION FOR FOUNDATION/EXCAVATION IS REQUIRED. |
| 03/15/2024 | SPECIAL INSPECTION FOR REINFORCING STEEL AND/OR PRE-STRESSING TENDONS IS REQUIRED. |
| 03/15/2024 | SPECIAL INSPECTION FOR SITE PREPARATION IS REQUIRED. |
| 03/15/2024 | SPECIAL INSPECTION FOR STRUCTURAL WELDING IS REQUIRED. |
| 03/15/2024 | WATER STERILIZATION REPORT IS REQUIRED. |
Conditions
Permit Number - T22CM04426
Permit Status: Issued
Permit Description: Interior remodel and new porch additions
| Date | Description | Comments |
|---|---|---|
| 02/13/2024 | Contractor with active Arizona Contractor's License for specified scope of work required prior to issuance of permit. Contractor must have a TDC Online account and be added to the permit as a contact. | |
| 03/15/2024 | Plan review applications expire 180 days from date of submittal unless the permit has been issued. Permits expire 180 days after issuance or last approved inspection. |
Outstanding Inspections
Permit Status: Issued
Permit Number: T22CM04426
Permite Description: Interior remodel and new porch additions
Total Outstanding Inspections - 27
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/26/2022 | COT - LCEL - Electrical Progress | N/A | Not Ready | |
| 10/27/2022 | COT - LCBU - Building Final | N/A | Not Ready | |
| 10/26/2022 | COT - LCEL - Electrical Underground | N/A | Not Ready | |
| 10/26/2022 | COT - LCME - Mechanical Progress | N/A | Not Ready | |
| 10/26/2022 | COT - FCON - Alarm - Final | N/A | Not Ready | |
| 10/27/2022 | COT - LCEL - Electrical Final | N/A | Not Ready | |
| 10/26/2022 | COT - FCON - Sprinkler - Final | N/A | Not Ready | |
| 10/26/2022 | COT - LCBU - Sustainability | N/A | Not Ready | |
| 10/26/2022 | COT - FCON - Fire - Final | N/A | Not Ready | |
| 10/26/2022 | COT - LCBU - Roof Nailing | N/A | Not Ready | |
| 10/26/2022 | COT - ENGR - Site - Assurance Release | N/A | Not Ready | |
| 10/26/2022 | COT - LCEL - Service Upgrade | N/A | Not Ready | |
| 10/26/2022 | COT - LCBU - Building Progress | N/A | Not Ready | |
| 10/26/2022 | COT - FCON - Hood System - Final | N/A | Not Ready | |
| 10/26/2022 | COT - LCPL - Gas Reconnect | N/A | Not Ready | |
| 10/26/2022 | COT - LCME - Mechanical Final | N/A | Not Ready | |
| 10/26/2022 | COT - LCPL - Plumbing Final | N/A | Not Ready | |
| 05/10/2023 | COT - LCME - Kitchen Hood | N/A | Partial Pass | 5/10/23: 2 new grease ducts smoke tested and approved. |
| 10/26/2022 | COT - LCBU - Building Above Ceiling | N/A | Not Ready | |
| 10/26/2022 | COT - LCEL - Electrical Intermediate | N/A | Not Ready | |
| 10/26/2022 | COT - LCME - Mechanical Above Ceiling | N/A | Not Ready | |
| 10/26/2022 | COT - LCME - Mechanical Intermediate | N/A | Not Ready | |
| 10/26/2022 | COT - LCPL - Gas Pressure Test | N/A | Not Ready | |
| 10/26/2022 | COT - HCBU - Interior Shear Bracing | N/A | Not Ready | |
| 01/21/2025 | COT - LCBU - Framing | N/A | Partial Pass | 1-21-25, partial pass for exterior framing-see conditions related to 3rd party inspections. |
| 04/15/2025 | COT - LCPL - Plumbing Intermediate | N/A | Re-inspection required | 4-15-25, grease interceptor changed from a 500 to a 250 gallon. Engineer to submit a revision to the city showing change. Contractor looking to backfill but wasn't under test. He will reschedule but was advised any construction for grease interceptor will be at own risk pending city review and approval. |
| 10/26/2022 | COT - LCPL - Plumbing Above Ceiling | N/A | Not Ready |
Completed Inspections
Permit Status: Issued
Permit Number: T22CM04426
Permit Description: Interior remodel and new porch additions
Total Completed Inspections - 13
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/08/2022 | BULD - Electrical Clearance | Passed | TEP INCR | |
| 10/13/2023 | COT - LCPL - Rough Soil | Passed | ||
| 10/13/2023 | COT - HCBU - Excavation/Rebar/Zoning | Passed | 10/13/23: okay to pour concrete rebar is to schedule | |
| 10/13/2023 | COT - HCBU - Preslab | Passed | 10/13/23: okay to pour concrete rebar is to schedule | |
| 06/28/2024 | COT - LCBU - Excavation/Rebar/Zoning | Passed | 6/28/24: Passed all monolithic footings/slab on grade areas on outside northeast corner, southwest corner, and interior footings for column posts. Okay to proceed with concrete pour. | |
| 07/22/2024 | COT - LCBU - Building Above Ceiling | Passed | Electrical, mechanical, and plumbing above ceiling is complete. Okay to proceed with grid ceiling installation.. | |
| 07/22/2024 | COT - LCEL - Electrical Intermediate | Passed | Electrical rough-in of walls and ceiling is complete. Okay to proceed with drywall installation. | |
| 07/22/2024 | COT - LCME - Mechanical Above Ceiling | Passed | Electrical, mechanical, and plumbing above ceiling is complete. Okay to proceed with grid ceiling installation.. | |
| 07/22/2024 | COT - LCME - Mechanical Intermediate | Passed | A/C units are installed, ductwork and registers are installed for both supply and return air, and thermostats are properly wired. Okay to proceed with further work. | |
| 07/22/2024 | COT - LCEL - Electrical Above Ceiling | Passed | Electrical, mechanical, and plumbing above ceiling is complete. Okay to proceed with grid ceiling installation.. | |
| 07/26/2024 | COT - LCPL - Plumbing Progress | Passed | 7/24/24: Plumbing rough-in is complete. Okay to proceed with installation of insulation and drywall on ceilings and walls. | |
| 08/19/2024 | COT - LCPL - Gas Pressure Test | Passed | ||
| 07/02/2025 | COT - LCPL - Plumbing Intermediate | Passed | 7/2/25 revision received, ok to connect and backfill |