Permit: T22CM02625
Permit Details
Status:
Issued
Type:
Residential Building - One or Two Family
Address:
5820 E 36TH ST
Address NEW:
5820 E 36TH ST
Apply Date:
04/11/2022
Applicant:
Martin Mendoza
Description:
R-Enclose Garage and Porch; Garage & Porch Addition
Permit Reviews
Permit Number - T22CM02625
Permit Status: Issued
Permit Description: R-Enclose Garage and Porch; Garage & Porch Addition
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 04/11/2022 | RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO | 04/29/2022 | COMPLETED |
| 05/19/2022 | RESUBMITTAL | 05/31/2022 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T22CM02625
Permit Status: Issued
Permit Description: R-Enclose Garage and Porch; Garage & Porch Addition
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 05/27/2022 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Outstanding Inspections
Permit Status: Issued
Permit Number: T22CM02625
Permite Description: R-Enclose Garage and Porch; Garage & Porch Addition
Total Outstanding Inspections - 3
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/14/2022 | COT - RSBU - Preslab | N/A | Canceled | {Activity date: 09/14/2022; Status: Not Applicable; Inspector: RCHANDLER; Comment: Entered by VVERA1 - -Not Applicable} |
| 10/26/2022 | COT - RSBU - Stem Wall/Retaining Wall | N/A | Not Ready | |
| 10/27/2022 | RSBU - Building Final | N/A | Not Ready |
Completed Inspections
Permit Status: Issued
Permit Number: T22CM02625
Permit Description: R-Enclose Garage and Porch; Garage & Porch Addition
Total Completed Inspections - 8
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/27/2022 | COT - RSBU - Excavation/Rebar/Zoning | Passed | {Activity date: 06/27/2022; Status: Approved; Inspector: RCHANDLER; Comment: Entered by VVERA1 - -AP Including stem wall and pre slab; no access to permit records at this time. } ; {Activity date: 06/23/2022; Status: Denied; Inspector: WGALLAGHER; Comment: Entered by NGARCIA3 - Denied no plans on site } |
|
| 07/21/2022 | COT - RSBU - Roof Nailing | Passed | {Activity date: 07/21/2022; Status: Approved; Inspector: DMUNIZ; Comment: Entered by NGARCIA3 - Approved} | |
| 07/21/2022 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Passed | {Activity date: 07/21/2022; Status: Approved; Inspector: DMUNIZ; Comment: Entered by NGARCIA3 - Approved} ; {Activity date: 07/14/2022; Status: Denied; Inspector: RCHANDLER; Comment: Entered by NGARCIA3 - -DE. 1-Install siding. 2-Provide engineering for rafters attached to fascia, or build according to approved plans. 3-Install headers per approved plans. } |
|
| 07/29/2022 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Passed | {Activity date: 07/29/2022; Status: Approved; Inspector: RCHANDLER; Comment: Entered by NGARCIA3 - Approved} ; {Activity date: 07/28/2022; Status: Denied; Inspector: TLUNDBERG; Comment: Entered by VVERA1 - DE Contractor installed siding against the framing without a vapor barrier, the approved plans call for a stucco system. Install a stucco system per plan, or resubmit for new plan review showing hardwood siding with vapor barrier.} ; {Activity date: 07/25/2022; Status: Partial Approval; Inspector: DMUNIZ; Comment: Entered by NGARCIA3 - PARTIAL, ok to Sheetrock addition, install #12 Romex in garage for 20amp ckt. Per plan. } |
|
| 09/14/2022 | COT - RSME - Mechanical Final | Passed | {Activity date: 09/14/2022; Status: Approved; Inspector: RCHANDLER; Comment: Entered by VVERA1 - Approved} | |
| 09/14/2022 | COT - LCBU - Framing | Passed | {Activity date: 09/14/2022; Status: Approved; Inspector: RCHANDLER; Comment: Entered by VVERA1 - Approved} | |
| 09/14/2022 | COT - RSEL - Outdoor Lighting | Passed | {Activity date: 09/14/2022; Status: Approved; Inspector: RCHANDLER; Comment: Entered by VVERA1 - Approved} | |
| 09/14/2022 | COT - RSEL - Electrical Final | Passed | {Activity date: 09/14/2022; Status: Approved; Inspector: RCHANDLER; Comment: Entered by VVERA1 - Approved} |