Permit: T22CM02098
Permit Details
Status:
Inspections
Type:
Residential Building - One or Two Family
Address:
934 W CALLE ANTONIA
Address NEW:
934 W CALLE ANTONIA
Apply Date:
03/22/2022
Applicant:
Fernando Hinojosa
Description:
R-Restroom and Closet Addition
Permit Reviews
Permit Number - T22CM02098
Permit Status: Inspections
Permit Description: R-Restroom and Closet Addition
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 03/22/2022 | RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO | 04/20/2022 | COMPLETED |
| 12/12/2022 | RESIDENTIAL NEW DWELLING v.1 | 01/09/2023 | REQUIRES RESUBMIT |
| 02/16/2023 | RESIDENTIAL NEW DWELLING v.2 | 03/09/2023 | APPROVED |
Conditions
Permit Number - T22CM02098
Permit Status: Inspections
Permit Description: R-Restroom and Closet Addition
| Date | Description | Comments |
|---|---|---|
| 09/20/2023 | The Contractor you have added to your permit cannot be verified. Please contact staff to have the ROC number added to the account. | |
| 09/05/2023 | Contractor with active Arizona Contractor's License for specified scope of work, or a signed Owner Builder Affidavit https://www.tucsonaz.gov/files/sharedassets/public/pdsd/documents/permits/residential-permits/pdsd_owner_builder_affidavit.pdf, is required prior to issuance of permit. Contractor or Owner must have a TDC Online account and be added to the permit as a contact. If you are providing an Owner Builder Affidavit, the owner MUST be attached as a contact on the permit. |
Outstanding Inspections
Permit Status: Inspections
Permit Number: T22CM02098
Permite Description: R-Restroom and Closet Addition
Total Outstanding Inspections - 5
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/12/2023 | COT - RSPL - Rough Soil | N/A | Re-inspection required | 1-Provide approved plans. 2-Tracer wire is missing. 3-Shower/tub vent connection is below the centerline of drain.(P3104.3) |
| 10/12/2023 | COT - RSBU - Excavation/Rebar/Zoning | N/A | Not Ready | |
| 10/12/2023 | COT - RSBU - Preslab | N/A | Not Ready | |
| 09/24/2024 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | N/A | Partial Pass | 9/24/24: Anchor bolts spacing shall be no greater than 48" o.c, Anchor bolts required 12" from edge of sill plate, framing at interior walls not per plan. Ok to lath/stucco. |
| 09/24/2024 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | N/A | Re-inspection required | 9/24/24: not ready for intermediate inspection. |
Completed Inspections
Permit Status: Inspections
Permit Number: T22CM02098
Permit Description: R-Restroom and Closet Addition
Total Completed Inspections - 4
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/17/2023 | COT - RSPL - Rough Soil | Passed | 10/17/23 ok to cover call pre-slab after your footers, and ready for concrete | |
| 11/20/2023 | COT - RSBU - Excavation/Rebar/Zoning | Passed | 1-Provide approved plans. 2-Existing line has been downsized by insertion of wye fitting. 3-Tracer wire is missing. 4-Multiple underground fittings are vent only fittings. 5- Shower vent connection is below the centerline of drain. 10/31/23: missing rebar at footing, plumbing not wrapped, screen needs to be elevated off ground 11/9/23: called at 10:15am no answer, knocked at house no answer, no access. 11/20/23: reinforcement per plan ok to pour. |
|
| 11/20/2023 | COT - RSBU - Preslab | Passed | 1-Provide approved plans. 2-Existing line has been downsized by insertion of wye fitting. 3-Tracer wire is missing. 4-Multiple underground fittings are vent only fittings. 5- Shower vent connection is below the centerline of drain. 10/31/23: missing rebar at footing, plumbing not wrapped, screen needs to be elevated off ground 11/9/23: called at 10:15am no answer, knocked at house no answer, no access. 11/20/23: reinforcement per plan ok to pour. |
|
| 09/24/2024 | COT - RSBU - Roof Nailing | Passed |