Permit Details

Status:
Inspections
Type:
Residential Building - One or Two Family
Address:
9024 E 21ST ST
Address NEW:
9024 E 21ST ST
Apply Date:
02/25/2022
Applicant:
Description:
R-Bedroom Addition

Permit Reviews

Permit Number - T22CM01397
Permit Status: Inspections
Permit Description: R-Bedroom Addition
Start Date Submittal Complete Date Status  
02/25/2022 RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO 03/22/2022 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T22CM01397
Permit Status: Inspections
Permit Description: R-Bedroom Addition
Total Outstanding Activity Conditions - 1
Date Name
03/22/2022 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Outstanding Inspections

Permit Status: Inspections
Permit Number: T22CM01397
Permite Description: R-Bedroom Addition
Total Outstanding Inspections - 9
Last Inspection Date Description Inspector Results Comments
10/26/2022 COT - RSBU - Preslab N/A Not Ready
06/16/2023 COT - LCBU - Framing N/A Not Ready
06/11/2024 RSEL - Electrical Progress N/A Not Ready
10/26/2022 COT - RSBU - Excavation/Rebar/Zoning N/A Not Ready
11/25/2025 COT - RSME - Mechanical Final N/A Re-inspection required 11-25-25: missing hammer arrestors at washer/dryer, install bubble covers at all exterior receptacles-receptacle covers must rated heavy duty while in use, paint all exterior plastic, install receptacle/bubble covers must rated at exterior side adjacent to mini split, seal/paint all exterior wood, missing arch fault breakers- arch faults are required in every habitable spaces, replace 70amp breaker at main with a 100 amp breaker, missing smoke detector in bedroom-must be hardwired, nm cable feeding can lights are not allowed in wet locations-refer to architect if record for fix & provide updated RFI, mini split is over amped-max breaker is 25amps.
11/25/2025 RSBU - Building Final N/A Re-inspection required 11-25-25: missing hammer arrestors at washer/dryer, install bubble covers at all exterior receptacles-receptacle covers must rated heavy duty while in use, paint all exterior plastic, install receptacle/bubble covers must rated at exterior side adjacent to mini split, seal/paint all exterior wood, missing arch fault breakers- arch faults are required in every habitable spaces, replace 70amp breaker at main with a 100 amp breaker, missing smoke detector in bedroom-must be hardwired, nm cable feeding can lights are not allowed in wet locations-refer to architect if record for fix & provide updated RFI, mini split is over amped-max breaker is 25amps.
11/25/2025 COT - RSPL - Plumbing Final N/A Re-inspection required 11-25-25: missing hammer arrestors at washer/dryer, install bubble covers at all exterior receptacles-receptacle covers must rated heavy duty while in use, paint all exterior plastic, install receptacle/bubble covers must rated at exterior side adjacent to mini split, seal/paint all exterior wood, missing arch fault breakers- arch faults are required in every habitable spaces, replace 70amp breaker at main with a 100 amp breaker, missing smoke detector in bedroom-must be hardwired, nm cable feeding can lights are not allowed in wet locations-refer to architect if record for fix & provide updated RFI, mini split is over amped-max breaker is 25amps.
12/05/2025 COT - RSEL - Electrical Final N/A Not Applicable duplicate
12/05/2025 COT - RSEL - Outdoor Lighting N/A Not Applicable duplicate

Completed Inspections

Permit Status: Inspections
Permit Number: T22CM01397
Permit Description: R-Bedroom Addition
Total Completed Inspections - 15
Date Description Inspector Results Comments
06/08/2022 COT - RSPL - Rough Soil Passed {Activity date: 06/08/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by VVERA1 - AP} ; {Activity date: 05/24/2022; Status: Denied; Inspector: RCHANDLER; Comment: Entered by NGARCIA3 - -DE. 1-Provide approved plans. 2-Provide water test.

}
01/06/2023 COT - RSBU - Preslab Passed footings under the sidewalk on west side
06/21/2023 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Passed
06/21/2023 COT - RSBU - Roof Nailing Passed
12/11/2024 COT - LCBU - Framing Passed Rough framing is complete, electrical and plumbing rough-in is complete with bang plates in place and all top plate penetrations are foamed. Okay to proceed with installation of insulation and drywall.
12/11/2024 RSEL - Electrical Progress Passed Rough framing is complete, electrical and plumbing rough-in is complete with bang plates in place and all top plate penetrations are foamed. Okay to proceed with installation of insulation and drywall.
12/11/2024 COT - LCPL - Plumbing Intermediate Passed Plumbing rough in is complete and under water test with no leaks. Okay to proceed with other work.
12/11/2024 COT - RSBU - Excavation/Rebar/Zoning Passed
08/14/2025 RSME - Mechanical Progress Passed Passed 8/5/25. Cutover to new 400ah panel delayed pending TEP installing new transformer and relocating telephone poles, customer temporarily wiring addition to existing 200ah panel that can handle additional load
11/25/2025 COT - RSPL - Sewer Passed 11-25-25: approved.
12/05/2025 COT - RSME - Mechanical Final Passed 12/5/25 CORRECTIONS MADE
12/05/2025 RSBU - Building Final Passed 12/5/25 CORRECTIONS MADE
12/05/2025 COT - RSPL - Plumbing Final Passed 12/5/25 CORRECTIONS MADE
12/05/2025 COT - RSEL - Electrical Final Passed 12/5/25 passed final
12/05/2025 COT - RSEL - Outdoor Lighting Passed 12/5/25 passed final

Documents

File Name Document Type  
APPLICATION 2024 MASS-UPLOAD.PDF DOCUMENTS VIEW
HVAC CALCULATIOS 2024 MASS-UPLOAD.PDF DOCUMENTS VIEW
JOB CARD 2024 MASS-UPLOAD.PDF DOCUMENTS VIEW
PERMIT 2024 MASS-UPLOAD.PDF DOCUMENTS VIEW
PLAN SET 2024 MASS-UPLOAD.PDF DOCUMENTS VIEW
APPLICATION.PDF DOCUMENTS VIEW
HVAC CALCULATIOS.PDF DOCUMENTS VIEW
JOB CARD.PDF DOCUMENTS VIEW
PERMIT.PDF DOCUMENTS VIEW
PLAN SET.PDF DOCUMENTS VIEW