Permit: T22CM00906
Permit Details
Status:
Complete
Type:
Residential Building - One or Two Family
Address:
3514 E FLOWER ST
Address NEW:
3514 E FLOWER ST
Apply Date:
02/07/2022
Applicant:
Description:
Sleeping Quarters
Permit Reviews
Permit Number - T22CM00906
Permit Status: Complete
Permit Description: Sleeping Quarters
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 02/07/2022 | RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO | 03/01/2022 | COMPLETED |
| 03/11/2022 | RESUBMITTAL | 04/05/2022 | COMPLETED |
Conditions
Permit Number - T22CM00906
Permit Status: Complete
Permit Description: Sleeping Quarters
| Date | Description | Comments |
|---|---|---|
| 03/25/2022 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Outstanding Inspections
Permit Status: Complete
Permit Number: T22CM00906
Permite Description: Sleeping Quarters
Total Outstanding Inspections - 4
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/26/2022 | COT - RSPL - Sewer | N/A | Not Ready | |
| 12/27/2022 | RSME - Mechanical Progress | N/A | Not Ready | lines are going to be relocated. |
| 12/27/2022 | COT - LCPL - Plumbing Intermediate | N/A | Not Ready | provide DWV test. space pex lines 12” from light fixtures. copper lines need to be 18” minimum before connecting to pex. provide fire foam at all top penetrations. |
| 01/24/2023 | COT - RSEL - Service Upgrade | N/A | Not Applicable | N/A |
Completed Inspections
Permit Status: Complete
Permit Number: T22CM00906
Permit Description: Sleeping Quarters
Total Completed Inspections - 13
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/10/2022 | COT - RSPL - Rough Soil | Passed | {Activity date: 06/10/2022; Status: Approved; Inspector: ESTEVENS; Comment: Entered by VVERA1 - Approved} ; {Activity date: 06/07/2022; Status: Cancelled; Inspector: WGALLAGHER; Comment: Entered by NGARCIA3 - Inspection canceled by contractor} | |
| 06/13/2022 | COT - RSEL - Grounding/Bonding | Passed | {Activity date: 06/13/2022; Status: Approved; Inspector: DQUINN; Comment: Entered by VVERA1 - Ap} | |
| 06/13/2022 | COT - RSBU - Preslab | Passed | {Activity date: 06/13/2022; Status: Approved; Inspector: DQUINN; Comment: Entered by VVERA1 - Ap} | |
| 06/13/2022 | COT - RSBU - Excavation/Rebar/Zoning | Passed | {Activity date: 06/13/2022; Status: Approved; Inspector: DQUINN; Comment: Entered by VVERA1 - Ap} | |
| 10/07/2022 | COT - RSBU - Roof Nailing | Passed | {Activity date: 10/07/2022; Status: Approved; Inspector: RCHANDLER; Comment: Entered by NGARCIA3 - AP} ; {Activity date: 09/16/2022; Status: Denied; Inspector: RCHANDLER; Comment: Entered by VVERA1 - Denied: Remove and re-nail all sheeting nails that missed trusses.} | |
| 10/07/2022 | COT - LCBU - Framing | Passed | {Activity date: 10/07/2022; Status: Approved; Inspector: RCHANDLER; Comment: Entered by NGARCIA3 - AP} ; {Activity date: 09/16/2022; Status: Denied; Inspector: RCHANDLER; Comment: Entered by VVERA1 - Denied. 1-Remove and re-nail all shear nails missing studs. 2-Provide approved plans. 3-Provide approved drawings for bearing point addition at front cantilever. 4-Move Ufer to inside of wall cavity. } |
|
| 01/24/2023 | RSME - Mechanical Progress | Passed | ||
| 01/24/2023 | COT - LCPL - Plumbing Intermediate | Passed | ||
| 05/11/2023 | COT - RSME - Mechanical Final | Passed | ||
| 05/11/2023 | COT - RSEL - Outdoor Lighting | Passed | ||
| 10/16/2023 | COT - RSPL - Plumbing Final | Passed | ||
| 10/16/2023 | RSBU - Building Final | Passed | ||
| 10/16/2023 | COT - RSEL - Electrical Final | Passed | Partial pending laundry room receptacle needs to be gfci. Missing lighting and switch in mechanical room. 5/11/2023 10/16/23: corrections made |