Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
Complete
Type:
Commercial Building
Address:
1929 E GRANT RD
Address NEW:
1929 E GRANT RD
Apply Date:
12/10/2021
Applicant:
Description:
Renovation of existing restaurant. No additional SF. Scope includes; Architecture, Structural, Mecha

Permit Reviews

Permit Number - T21CM09437
Permit Status: Complete
Permit Description: Renovation of existing restaurant. No additional SF. Scope includes; Architecture, Structural, Mecha
Start Date Submittal Complete Date Status  
02/25/2022 RESUBMITTAL 03/10/2022 COMPLETED Review Details
03/12/2022 RESUBMITTAL 03/16/2022 COMPLETED Review Details
12/10/2021 COMMERCIAL - TI 02/24/2022 COMPLETED Review Details
12/27/2022 BUILDING DEFERRED SUBMITTAL REVIEW v.1 01/04/2023 APPROVED Review Details

Outstanding Activity Conditions

Permit Number - T21CM09437
Permit Status: Complete
Permit Description: Renovation of existing restaurant. No additional SF. Scope includes; Architecture, Structural, Mecha
Total Outstanding Activity Conditions - 6
Date Name
02/23/2022 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.
02/23/2022 SPECIAL INSPECTION FOR WELD REINF STEEL IS REQUIRED.
02/23/2022 SPECIAL INSPECTION FOR STRUCTURAL MASONRY IS REQUIRED.
02/23/2022 SPECIAL INSPECTION FOR EXPANSION ANCHORS IS REQUIRED.
02/23/2022 SHOP DRAWINGS REQUIRED FOR KITCHEN HOOD SUPPRESSION SYSTEM.
02/23/2022 SHOP DRAWINGS REQUIRED FOR PRE-ENGINEERED STEEL TRUSSES.

Conditions

Permit Number - T21CM09437
Permit Status: Complete
Permit Description: Renovation of existing restaurant. No additional SF. Scope includes; Architecture, Structural, Mecha
Date Description Comments
02/23/2022 SPECIAL INSPECTION FOR EPOXY ANCHORS IS REQUIRED.
02/23/2022 SPECIAL INSPECTION IS REQUIRED FOR STRUCTURAL STEEL.
02/23/2022 SPECIAL INSPECTION IS REQUIRED FOR HIGH STRENGTH BOLTS.

Outstanding Inspections

Permit Status: Complete
Permit Number: T21CM09437
Permite Description: Renovation of existing restaurant. No additional SF. Scope includes; Architecture, Structural, Mecha
Total Outstanding Inspections - 6
Last Inspection Date Description Inspector Results Comments
09/15/2022 COT - LCBU - Stem Wall/Retaining Wall N/A Canceled {Activity date: 09/15/2022; Status: Not Applicable; Inspector: TGAUSP; Comment: Entered by NGARCIA3 - NA}
09/15/2022 COT - LCBU - Excavation/Rebar/Zoning N/A Canceled {Activity date: 09/15/2022; Status: Not Applicable; Inspector: TGAUSP; Comment: Entered by NGARCIA3 - NA}
09/15/2022 COT - LCBU - Exterior Clips/Sheathing N/A Canceled {Activity date: 09/15/2022; Status: Not Applicable; Inspector: TGAUSP; Comment: Entered by NGARCIA3 - NA}
09/15/2022 COT - LCBU - Roof Nailing N/A Canceled {Activity date: 09/15/2022; Status: Not Applicable; Inspector: TGAUSP; Comment: Entered by NGARCIA3 - NA}
09/15/2022 COT - LCBU - Masonry Pregrout N/A Canceled {Activity date: 09/15/2022; Status: Not Applicable; Inspector: TGAUSP; Comment: Entered by NGARCIA3 - NA}
10/26/2022 COT - FCON - Fire - Final N/A Not Ready

Completed Inspections

Permit Status: Complete
Permit Number: T21CM09437
Permit Description: Renovation of existing restaurant. No additional SF. Scope includes; Architecture, Structural, Mecha
Total Completed Inspections - 31
Date Description Inspector Results Comments
04/08/2022 COT - LCEL - Electrical Underground Passed {Activity date: 04/08/2022; Status: Approved; Inspector: TGAUSP; Comment: Entered by NGARCIA3 - Approved}
04/08/2022 COT - LCBU - Preslab Passed {Activity date: 04/08/2022; Status: Approved; Inspector: TGAUSP; Comment: Entered by NGARCIA3 - Approved, okay for concrete placement}
04/08/2022 COT - LCPL - Rough Soil Passed {Activity date: 04/08/2022; Status: Approved; Inspector: TGAUSP; Comment: Entered by NGARCIA3 - Approved, 250 gal grease trap, okay to backfill} ; {Activity date: 04/01/2022; Status: Partial Approval; Inspector: DQUINN; Comment: Entered by VVERA1 - pa
All interior pvc drains ok to backfill.}
05/02/2022 COT - LCEL - Electrical Intermediate Passed {Activity date: 05/02/2022; Status: Approved; Inspector: DQUINN; Comment: Entered by VVERA1 - Ap} ; {Activity date: 04/07/2022; Status: Partial Approval; Inspector: DQUINN; Comment: Entered by NGARCIA3 - pa
Under slab conduit ok to backfill}
05/02/2022 COT - LCBU - Framing Passed {Activity date: 05/02/2022; Status: Approved; Inspector: DQUINN; Comment: Entered by VVERA1 - Ap}
05/02/2022 COT - LCME - Mechanical Above Ceiling Passed {Activity date: 05/02/2022; Status: Approved; Inspector: DQUINN; Comment: Entered by VVERA1 - Ap

Clear gas}
05/02/2022 COT - LCPL - Plumbing Above Ceiling Passed {Activity date: 05/02/2022; Status: Approved; Inspector: DQUINN; Comment: Entered by VVERA1 - Ap}
05/02/2022 COT - LCEL - Electrical Above Ceiling Passed {Activity date: 05/02/2022; Status: Approved; Inspector: DQUINN; Comment: Entered by VVERA1 - Ap}
05/02/2022 COT - LCME - Mechanical Intermediate Passed {Activity date: 05/02/2022; Status: Approved; Inspector: DQUINN; Comment: Entered by VVERA1 - Ap}
07/29/2022 COT - LCBU - Building Above Ceiling Passed {Activity date: 07/29/2022; Status: Approved; Inspector: DQUINN; Comment: Entered by NGARCIA3 - Ap
Ok to drop tiles}
08/08/2022 PDSD Building Division - TEP PM Clearance Passed {Activity date: 08/08/2022; Status: Approved; Inspector: DQUINN; Comment: Entered by VVERA1 - CODE INCR} ; {Activity date: 03/25/2022; Status: Approved; Inspector: DQUINN; Comment: Entered by NGARCIA3 - CODE REC- POWER IS ON- NEED TEP LOCK REMOVED}
08/08/2022 COT - LCEL - Construction Power Passed {Activity date: 08/08/2022; Status: Approved; Inspector: DQUINN; Comment: Entered by VVERA1 - Ap}
08/08/2022 COT - LCEL - Service Upgrade Passed {Activity date: 08/08/2022; Status: Approved; Inspector: DQUINN; Comment: Entered by VVERA1 - Ap

Clear incr}
08/08/2022 COT - LCEL - Grounding/Bonding Passed {Activity date: 08/08/2022; Status: Approved; Inspector: DQUINN; Comment: Entered by VVERA1 - Ap}
08/23/2022 COT - LCPL - Gas Pressure Test Passed {Activity date: 08/23/2022; Status: Approved; Inspector: DQUINN; Comment: Entered by NGARCIA3 - Ap
Called SWG at 10:35

Clear gas}
08/23/2022 COT - BULD - SWG Clearance Passed {Activity date: 08/23/2022; Status: Approved; Inspector: DQUINN; Comment: Entered by NGARCIA3 - CODE GAS} ; {Activity date: 05/02/2022; Status: Approved; Inspector: DQUINN; Comment: Entered by VVERA1 - CODE}
10/03/2022 COT - LCBU - Sustainability Passed {Activity date: 10/03/2022; Status: Approved; Inspector: WGALLAGHER; Comment: Entered by NGARCIA3 - Approved}
10/07/2022 COT - LCEL - Electrical Progress Passed {Activity date: 10/07/2022; Status: Approved; Inspector: ESTEVENS; Comment: Entered by NGARCIA3 - Approved}
10/07/2022 COT - LCME - Mechanical Progress Passed {Activity date: 10/07/2022; Status: Approved; Inspector: ESTEVENS; Comment: Entered by NGARCIA3 - Approved}
10/07/2022 COT - LCME - Kitchen Hood Passed {Activity date: 10/07/2022; Status: Approved; Inspector: ESTEVENS; Comment: Entered by NGARCIA3 - Approved}
10/07/2022 COT - LCEL - Outdoor Lighting Passed {Activity date: 10/07/2022; Status: Approved; Inspector: ESTEVENS; Comment: Entered by NGARCIA3 - Approved}
10/07/2022 COT - LCPL - Plumbing Intermediate Passed {Activity date: 10/07/2022; Status: Approved; Inspector: ESTEVENS; Comment: Entered by NGARCIA3 - Approved} ; {Activity date: 05/02/2022; Status: Approved; Inspector: DQUINN; Comment: Entered by VVERA1 - Ap}
10/07/2022 COT - LCBU - Building Progress Passed {Activity date: 10/07/2022; Status: Approved; Inspector: ESTEVENS; Comment: Entered by NGARCIA3 - Approved}
10/07/2022 COT - HCBU - Interior Shear Bracing Passed {Activity date: 10/07/2022; Status: Approved; Inspector: ESTEVENS; Comment: Entered by NGARCIA3 - Approved}
10/12/2022 COT - FCON - Hood System - Final Passed {Activity date: 10/12/2022; Status: Approved; Inspector: CBASALDUA; Comment: Entered by CBASALD1 - }
10/14/2022 COT - LCBU - Building Final Passed {Activity date: 10/14/2022; Status: Approved; Inspector: RCHANDLER; Comment: Entered by NGARCIA3 - AP} ; {Activity date: 10/07/2022; Status: Partial Approval; Inspector: ESTEVENS; Comment: Entered by NGARCIA3 - Partial. Missing two GFI receptacles, missing electrical labels on panel box, toilet to not meet ADA 16 to 18 inch specifications. Missing hinge on grease exhaust fan, missing grease cup at exhaust fan}
10/14/2022 COT - LCPL - Plumbing Progress Passed {Activity date: 10/14/2022; Status: Approved; Inspector: RCHANDLER; Comment: Entered by NGARCIA3 - AP}
10/14/2022 COT - LCME - Mechanical Final Passed {Activity date: 10/14/2022; Status: Approved; Inspector: RCHANDLER; Comment: Entered by NGARCIA3 - AP} ; {Activity date: 10/10/2022; Status: Partial Approval; Inspector: RSHERRY; Comment: Entered by RSHERRY1 - REVIEW OF AIR BALANCE REPORT COMPLETED} ; {Activity date: 10/07/2022; Status: Partial Approval; Inspector: ESTEVENS; Comment: Entered by NGARCIA3 - Partial. Missing two GFI receptacles, missing electrical labels on panel box, toilet to not meet ADA 16 to 18 inch specifications. Missing hinge on grease exhaust fan, missing grease cup at exhaust fan}
10/14/2022 COT - LCEL - Electrical Final Passed {Activity date: 10/14/2022; Status: Approved; Inspector: RCHANDLER; Comment: Entered by NGARCIA3 - AP} ; {Activity date: 10/07/2022; Status: Partial Approval; Inspector: ESTEVENS; Comment: Entered by NGARCIA3 - Partial. Missing two GFI receptacles, missing electrical labels on panel box, toilet to not meet ADA 16 to 18 inch specifications. Missing hinge on grease exhaust fan, missing grease cup at exhaust fan}
10/14/2022 COT - LCEL - Electrical Reconnect Passed {Activity date: 10/14/2022; Status: Approved; Inspector: RCHANDLER; Comment: Entered by NGARCIA3 - AP}
10/14/2022 COT - LCPL - Plumbing Final Passed {Activity date: 10/14/2022; Status: Approved; Inspector: RCHANDLER; Comment: Entered by NGARCIA3 - AP} ; {Activity date: 10/10/2022; Status: Partial Approval; Inspector: RSHERRY; Comment: Entered by RSHERRY1 - REVIEW OF WATER DISINFECTION REPORT COMPLETED} ; {Activity date: 10/07/2022; Status: Partial Approval; Inspector: ESTEVENS; Comment: Entered by NGARCIA3 - Partial. Missing two GFI receptacles, missing electrical labels on panel box, toilet to not meet ADA 16 to 18 inch specifications. Missing hinge on grease exhaust fan, missing grease cup at exhaust fan} ; {Activity date: 09/15/2022; Status: Partial Approval; Inspector: TGAUSP; Comment: Entered by NGARCIA3 - Partial, pending Building and Water Chlorination Report}

Documents

File Name Document Type  
T21CM09437 - TCO 2024 MASS-UPLOAD.PDF DOCUMENTS VIEW
T21CM09437 - TCO.PDF DOCUMENTS VIEW
FINAL SIC-2022-12-06_V1.PDF DOCUMENTS VIEW
COFO_FINALCOFO_COMMERCIAL.PDF DOCUMENTS VIEW
APPLICATION.PDF DOCUMENTS VIEW
PERMIT.PDF DOCUMENTS VIEW
JOB CARD.PDF DOCUMENTS VIEW
STANTEC PSA.PDF DOCUMENTS VIEW
SPECIAL INSPECTION CERT.PDF DOCUMENTS VIEW
SUBMITTAL REQUIREMENT CHECKLIST.PDF DOCUMENTS VIEW
STRUCTURAL CALCS.PDF DOCUMENTS VIEW
PLAN SET.PDF CONSTRPLANS VIEW