Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
Complete
Type:
Commercial Building
Apply Date:
09/15/2021
Applicant:
Description:
Tenant improvement of existing Target

Permit Reviews

Permit Number - T21CM07412
Permit Status: Complete
Permit Description: Tenant improvement of existing Target
Start Date Submittal Complete Date Status  
09/15/2021 COMMERCIAL - BLDG/FIRE/ZONING/ENG 10/13/2021 COMPLETED Review Details
10/26/2021 RESUBMITTAL 11/08/2021 COMPLETED Review Details
11/23/2021 RESUBMITTAL 11/24/2021 COMPLETED Review Details
12/30/2022 BUILDING DEFERRED SUBMITTAL REVIEW v.1 01/13/2023 APPROVED Review Details

Conditions

Permit Number - T21CM07412
Permit Status: Complete
Permit Description: Tenant improvement of existing Target
Date Description Comments
11/24/2021 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Outstanding Inspections

Permit Status: Complete
Permit Number: T21CM07412
Permite Description: Tenant improvement of existing Target
Total Outstanding Inspections - 1
Last Inspection Date Description Inspector Results Comments
10/26/2022 COT - FCON - Alarm - Final N/A Not Ready

Completed Inspections

Permit Status: Complete
Permit Number: T21CM07412
Permit Description: Tenant improvement of existing Target
Total Completed Inspections - 22
Date Description Inspector Results Comments
03/10/2022 COT - LCPL - Plumbing Intermediate Passed {Activity date: 03/10/2022; Status: Approved; Inspector: ESTEVENS; Comment: Entered by VVERA1 - Approved}
03/24/2022 COT - LCME - Mechanical Above Ceiling Passed {Activity date: 03/24/2022; Status: Approved; Inspector: ESTEVENS; Comment: Entered by VVERA1 - Approved} ; {Activity date: 03/16/2022; Status: Partial Approval; Inspector: WGALLAGHER; Comment: Entered by VVERA1 - Partial approval front stock room grid lines 8-9 A-C
}
03/25/2022 COT - LCME - Mechanical Intermediate Passed {Activity date: 03/25/2022; Status: Approved; Inspector: ESTEVENS; Comment: Entered by NGARCIA3 - Approved}
04/01/2022 COT - LCPL - Plumbing Progress Passed {Activity date: 04/01/2022; Status: Approved; Inspector: DMUNIZ; Comment: Entered by VVERA1 - Approved} ; {Activity date: 03/30/2022; Status: Not ready for Inspection; Inspector: DMUNIZ; Comment: Entered by VVERA1 - Not Ready, called contact multiple times, re call inspection and provide correct information.} ; {Activity date: 03/18/2022; Status: Partial Approval; Inspector: TGAUSP; Comment: Entered by VVERA1 - Partial for underground soil at Starbuck’s and Training room okay backfill progress areas}
06/13/2022 COT - LCEL - Electrical Above Ceiling Passed {Activity date: 06/13/2022; Status: Approved; Inspector: RCHANDLER; Comment: Entered by VVERA1 - AP} ; {Activity date: 04/13/2022; Status: Partial Approval; Inspector: DMUNIZ; Comment: Entered by VVERA1 - Partial, training room, lounge, Starbucks ok to drop ceiling tiles.}
06/15/2022 COT - LCEL - Electrical Intermediate Passed {Activity date: 06/15/2022; Status: Approved; Inspector: RCHANDLER; Comment: Entered by VVERA1 - AP} ; {Activity date: 05/11/2022; Status: Partial Approval; Inspector: WGALLAGHER; Comment: Entered by VVERA1 - Partial approval
For room TSC ROOMS Including vestibule and HR room only

} ; {Activity date: 05/10/2022; Status: Cancelled; Inspector: IVR USER; Comment: Entered by IVR USER - IVRS - AP canceled} ; {Activity date: 05/05/2022; Status: Partial Approval; Inspector: ESTEVENS; Comment: Entered by NGARCIA3 - Partial. Cash room.} ; {Activity date: 03/10/2022; Status: Approved; Inspector: ESTEVENS; Comment: Entered by VVERA1 - Approved}
07/19/2022 COT - LCBU - Building Progress Passed {Activity date: 07/19/2022; Status: Approved; Inspector: WGALLAGHER; Comment: Entered by NGARCIA3 - Approved} ; {Activity date: 05/23/2022; Status: Partial Approval; Inspector: DMUNIZ; Comment: Entered by VVERA1 - PARTIAL, TSC room above ceiling ok to proceed.

}
07/26/2022 COT - LCBU - Building Above Ceiling Passed {Activity date: 07/26/2022; Status: Approved; Inspector: ESTEVENS; Comment: Entered by NGARCIA3 - Approved}
07/26/2022 COT - LCEL - Electrical Progress Passed {Activity date: 07/26/2022; Status: Approved; Inspector: ESTEVENS; Comment: Entered by NGARCIA3 - Approved} ; {Activity date: 06/24/2022; Status: Partial Approval; Inspector: WGALLAGHER; Comment: Entered by NGARCIA3 - Partial approval for guest service stock room only OH electrical} ; {Activity date: 04/29/2022; Status: Partial Approval; Inspector: ESTEVENS; Comment: Entered by VVERA1 - Partial. Drywall and shearwalls in cash room.}
07/26/2022 COT - LCME - Mechanical Progress Passed {Activity date: 07/26/2022; Status: Approved; Inspector: ESTEVENS; Comment: Entered by NGARCIA3 - Approved} ; {Activity date: 06/24/2022; Status: Partial Approval; Inspector: WGALLAGHER; Comment: Entered by NGARCIA3 - Partial approval for guest Service, and OPU area ok to insulate ductwork

}
07/26/2022 COT - LCBU - Preslab Passed {Activity date: 07/26/2022; Status: Approved; Inspector: ESTEVENS; Comment: Entered by NGARCIA3 - Approved} ; {Activity date: 05/24/2022; Status: Partial Approval; Inspector: DMUNIZ; Comment: Entered by NGARCIA3 - Partial, Dowels installed for insulated slab footings. Documentation of finished re Bar #3-18” OC each way is required.} ; {Activity date: 03/18/2022; Status: Partial Approval; Inspector: TGAUSP; Comment: Entered by VVERA1 - Partial for Starbuck’s and Training room saw cuts, okay to cover.
}
07/26/2022 COT - LCPL - Plumbing Above Ceiling Passed {Activity date: 07/26/2022; Status: Approved; Inspector: ESTEVENS; Comment: Entered by NGARCIA3 - Approved}
07/26/2022 COT - HCBU - Interior Shear Bracing Passed {Activity date: 07/26/2022; Status: Approved; Inspector: ESTEVENS; Comment: Entered by NGARCIA3 - Approved} ; {Activity date: 03/16/2022; Status: Partial Approval; Inspector: WGALLAGHER; Comment: Entered by VVERA1 - Partial approval for room 137 lounge, south and west walls ok to 2 side
}
08/02/2022 COT - LCPL - Rough Soil Passed {Activity date: 08/02/2022; Status: Approved; Inspector: WGALLAGHER; Comment: Entered by NGARCIA3 - Approved} ; {Activity date: 03/16/2022; Status: Partial Approval; Inspector: WGALLAGHER; Comment: Entered by VVERA1 - Partial approval for Starbucks area GRID LINE B-C AND 1-2

}
08/05/2022 COT - LCEL - Electrical Final Passed {Activity date: 08/05/2022; Status: Approved; Inspector: WGALLAGHER; Comment: Entered by VVERA1 - Approved} ; {Activity date: 08/02/2022; Status: Partial Approval; Inspector: WGALLAGHER; Comment: Entered by NGARCIA3 - Partial approval please label all panels and outlets} ; {Activity date: 04/29/2022; Status: Partial Approval; Inspector: ESTEVENS; Comment: Entered by VVERA1 - Partial. Phase 1. Training and lounge rooms.

}
08/10/2022 COT - FCON - Sprinkler - Final Passed {Activity date: 08/10/2022; Status: Approved; Inspector: CGates; Comment: Entered by CGATES1 - Approved on T22FC00200 7/29/22.}
08/12/2022 COT - LCPL - Plumbing Final Passed {Activity date: 08/12/2022; Status: Approved; Inspector: WGALLAGHER; Comment: Entered by NGARCIA3 - Approved} ; {Activity date: 08/02/2022; Status: Partial Approval; Inspector: WGALLAGHER; Comment: Entered by NGARCIA3 - Partial approval condensates are traping water} ; {Activity date: 05/31/2022; Status: Partial Approval; Inspector: RSHERRY; Comment: Entered by RSHERRY1 - REVIEW OF WATER DISINFECTION REPORT COMPLETED} ; {Activity date: 04/29/2022; Status: Partial Approval; Inspector: ESTEVENS; Comment: Entered by VVERA1 - Partial. Phase 1. Training and lounge rooms.

} ; {Activity date: 11/24/2021; Status: Prior to Final Inspectn; Inspector: DBENOIT; Comment: Entered by DBENOIT1 - WATER CHLORINATION REPORT REQUIRED PRIOR TO FINAL INSPECTION}
12/16/2022 COT - FCON - Alarm - Final Passed Approved on 10/18/22 permit #T22FC00169
12/16/2022 COT - LCBU - Framing Passed
12/16/2022 COT - LCBU - Building Final Passed
12/16/2022 COT - LCME - Mechanical Final Passed
12/16/2022 COT - FCON - Fire - Final Passed

Documents

File Name Document Type  
LOFC_LETTEROFCOMPLETION.PDF DOCUMENTS VIEW
TARGET STORE T-1439 STARBUCKS EL CON PLAN FINAL APPROVED 5.23.22_V1.PDF DOCUMENTS VIEW
TARGET T1439 - DOMESTIC WATER STERILIZATION REPORT-2022-12-16_V1.PDF DOCUMENTS VIEW
TARGET T1439 - TEST - BALANCE REPORT_V1.PDF DOCUMENTS VIEW
MECHANICAL COMCHECK.PDF DOCUMENTS VIEW
JOB CARD.PDF DOCUMENTS VIEW
ELECTRICAL COMCHECK.PDF DOCUMENTS VIEW
ASBESTOS INSPECTION FINAL.PDF DOCUMENTS VIEW
APPLICATION.PDF DOCUMENTS VIEW
PLAN SET.PDF CONSTRPLANS VIEW
STRUCTURAL CALCULATIONS.PDF DOCUMENTS VIEW
PERMIT.PDF DOCUMENTS VIEW
PROJECT SPECIFICATIONS.PDF DOCUMENTS VIEW
PERMIT.PDF DOCUMENTS VIEW