Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Complete
Type:
Commercial Building
Address NEW:
2900 N CRAYCROFT RD
Apply Date:
08/10/2021
Applicant:
Derek Fenton
Description:
Bath House Improvements, Demo Existing Wading Pool, New Splash Pad

Permit Reviews

Permit Number - T21CM06468
Permit Status: Complete
Permit Description: Bath House Improvements, Demo Existing Wading Pool, New Splash Pad
Start Date Submittal Complete Date Status  
05/11/2022 RESUBMITTAL 05/24/2022 COMPLETED Review Details
08/09/2022 RESUBMITTAL 08/16/2022 COMPLETED Review Details
08/10/2021 COMMERCIAL - BLDG/FIRE/ZONING/ENG 02/09/2022 COMPLETED Review Details
02/10/2025 BUILDING DEFERRED SUBMITTAL REVIEW v.2 02/11/2025 APPROVED Review Details
05/22/2023 RESTAMP - COMMERCIAL v.1 05/25/2023 APPROVED Review Details
06/21/2024 BUILDING DEFERRED SUBMITTAL REVIEW v.1 06/21/2024 REQUIRES RESUBMIT Review Details
05/03/2023 COMMERCIAL REVIEW - FULL v.1 05/22/2023 APPROVED Review Details

Conditions

Permit Number - T21CM06468
Permit Status: Complete
Permit Description: Bath House Improvements, Demo Existing Wading Pool, New Splash Pad
Date Description Comments
08/16/2022 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.
08/16/2022 SPECIAL INSPECTION FOR STRUCTURAL WELDING IS REQUIRED.
08/16/2022 SPECIAL INSPECTION FOR STRUCTURAL MASONRY IS REQUIRED.
08/16/2022 SPECIAL INSPECTION FOR EXPANSION ANCHORS IS REQUIRED.
07/27/2023 The Contractor you have added to your permit cannot be verified. Please contact staff to have the ROC number added to the account.
05/25/2023 Contractor with active Arizona Contractor's License for specified scope of work required prior to issuance of permit.
02/11/2025 SPECIAL INSPECTION FOR PILING, DRILLED PIERS AND CAISSONS IS REQUIRED.

Outstanding Inspections

Permit Status: Complete
Permit Number: T21CM06468
Permite Description: Bath House Improvements, Demo Existing Wading Pool, New Splash Pad
Total Outstanding Inspections - 2
Last Inspection Date Description Inspector Results Comments
03/04/2024 COT - LCBU - Preslab N/A Partial Pass water recycling pit.
12/04/2024 COT - HCPL - Gas Pressure Test N/A Not Applicable

Completed Inspections

Permit Status: Complete
Permit Number: T21CM06468
Permit Description: Bath House Improvements, Demo Existing Wading Pool, New Splash Pad
Total Completed Inspections - 12
Date Description Inspector Results Comments
03/25/2024 COT - HCPL - Rough Soil Passed
05/06/2024 BULD - Electrical Clearance Passed Left voicemail with Natalie at 10:14AM.
06/28/2024 COT - LCBU - Preslab Passed pass
07/12/2024 COT - HCPL - Plumbing Intermediate Passed
08/01/2024 COT - BULD - SWG Clearance Passed
08/02/2024 COT - FCON - Fire - Final Passed
08/05/2024 ENGR Engineering Final Passed
08/02/2024 TRSP - ROW - Final/Close-Out Passed
08/19/2024 COT - LCBU - Building Final Passed
08/19/2024 COT - LCEL - Electrical Final Passed
08/19/2024 COT - LCPL - Plumbing Final Passed
12/04/2024 COT - LCME - Mechanical Final Passed

Documents

File Name Document Type  
COFO_FINALCOFO_COMMERCIAL.PDF DOCUMENTS VIEW
LOFC_LETTEROFCOMPLETION.PDF DOCUMENTS VIEW
COFT - PDSD - PERMIT CARD.PDF DOCUMENTS VIEW
CONS-T21CM06468 APPROVED STAMPED PLAN SET_V1.PDF DOCUMENTS VIEW
STRUCTURAL CALCS_V1.PDF DOCUMENTS VIEW
1_APPLICATION_V1.PDF DOCUMENTS VIEW