Permit: T21CM06092
Permit Details
Status:
Inspections
Type:
Residential Building - One or Two Family
Address:
8161 E BEVERLY ST
Address NEW:
8161 E BEVERLY ST
Apply Date:
07/27/2021
Applicant:
Description:
Remodel and Enclose Porch into Bedroom & Closet
Permit Reviews
Permit Number - T21CM06092
Permit Status: Inspections
Permit Description: Remodel and Enclose Porch into Bedroom & Closet
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 04/01/2022 | RESUBMITTAL | 04/06/2022 | COMPLETED |
| 07/27/2021 | RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO | 08/25/2021 | COMPLETED |
Outstanding Inspections
Permit Status: Inspections
Permit Number: T21CM06092
Permite Description: Remodel and Enclose Porch into Bedroom & Closet
Total Outstanding Inspections - 8
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/27/2022 | COT - RSME - Mechanical Final | N/A | Not Ready | |
| 10/26/2022 | COT - RSBU - Preslab | N/A | Not Ready | |
| 10/27/2022 | RSBU - Building Final | N/A | Not Ready | |
| 10/26/2022 | COT - RSEL - Service Upgrade | N/A | Not Ready | |
| 10/26/2022 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | N/A | Not Ready | |
| 07/25/2023 | RSME - Mechanical Progress | N/A | Canceled | 7/25/23: cancel per Cesar. |
| 12/09/2024 | COT - RSPL - Gas Pressure Test | N/A | Re-inspection required | No air in gas lines, requires a minimum of 15# psi of air pressure to pass inspection. |
| 02/28/2025 | COT - RSPL - Plumbing Final | N/A | Canceled | canceled, water heater not plumbed in |
Completed Inspections
Permit Status: Inspections
Permit Number: T21CM06092
Permit Description: Remodel and Enclose Porch into Bedroom & Closet
Total Completed Inspections - 9
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/30/2022 | COT - RSBU - Excavation/Rebar/Zoning | Passed | {Activity date: 06/30/2022; Status: Approved; Inspector: WGALLAGHER; Comment: Entered by NGARCIA3 - Approved} | |
| 03/14/2023 | COT - RSBU - Roof Nailing | Passed | ||
| 06/22/2023 | COT - LCBU - Framing | Passed | 5/19/23: canceled per Cesar | |
| 05/25/2023 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Passed | ||
| 06/07/2023 | COT - RSPL - Rough Soil | Passed | ||
| 07/21/2023 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Passed | 6/22/23: all penetrations to top plate must be sealed, all hvac boxes must be blocked on 3 sides, mechanical flex must be attached to air supply. Exhaust fans missing in bathroom and laundry room. Nail plates missing for plumbing in bathroom and kitchen, over notched studs need stud-shoe. Outside lathe must be done before intermediate inspection. 7/21/23: corrections made |
|
| 04/04/2024 | COT - RSEL - Electrical Final | Passed | ||
| 02/28/2025 | COT - BULD - SWG Clearance | Passed | Passed CLEARANCE SWG 2/28/25 | |
| 02/28/2025 | COT - RSPL - Gas Pressure Test | Passed | 2/28/25 passed, held pressure |