Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
Issued
Type:
Commercial Building
Address:
244 W FLORES ST
Apply Date:
07/13/2021
Applicant:
Description:
(T20DV02355) Rehab of existing structures based on damage from previous owners. No new expansion. E

Permit Reviews

Permit Number - T21CM05716
Permit Status: Issued
Permit Description: (T20DV02355) Rehab of existing structures based on damage from previous owners. No new expansion. E
Start Date Submittal Complete Date Status  
04/11/2022 REVISION - - 1ST 05/06/2022 COMPLETED Review Details
06/04/2022 REVISION - - 1ST 07/05/2022 COMPLETED Review Details
07/13/2021 COMMERCIAL - TI 08/19/2021 COMPLETED Review Details
08/31/2021 RESUBMITTAL 09/14/2021 COMPLETED Review Details
02/10/2023 COMMERCIAL REVIEW - FULL v.1 02/13/2023 REQUIRES RESUBMIT Review Details
03/13/2023 BUILDING DEFERRED SUBMITTAL REVIEW v.1 04/06/2023 APPROVED Review Details
02/16/2023 COMMERCIAL REVIEW - FULL v.2 02/28/2023 APPROVED Review Details
04/18/2023 BUILDING DEFERRED SUBMITTAL REVIEW v.1 05/01/2023 APPROVED Review Details
01/11/2023 COMMERCIAL REVIEW - FULL v.1 01/30/2023 APPROVED Review Details

Outstanding Activity Conditions

Permit Number - T21CM05716
Permit Status: Issued
Permit Description: (T20DV02355) Rehab of existing structures based on damage from previous owners. No new expansion. E
Total Outstanding Activity Conditions - 6
Date Name
02/27/2023 AIR BALANCING REPORT IS REQUIRED.
04/13/2022 ROOF TRUSSES MUST BE APPROVED PRIOR TO FRAMING INSPECTION (P2I)
04/13/2022 SPECIAL INSPECTION FORMS AND REPORTS REQUIRED PRIOR TO ISSUANCE OF A CERTIFICATE OF OCCUPANCY.
04/13/2022 SPECIAL INSPECTION FOR EPOXY ANCHORS IS REQUIRED.
05/01/2023 Structural analysis of the existing building masonry walls at new roof joist locations as identified by Terracon per report dated 3/22/2023. Report number 63231035.0001. Notified Nick / DZ Builders that existing walls appeared not to be grouted and no reinforcing steel was present at time of inspection. Notified Nick that they should call structural engineer for site visit and recommendations for grout and wall reinforcement placement.
05/01/2023 SPECIAL INSPECTION FOR STRUCTURAL MASONRY IS REQUIRED.

Conditions

Permit Number - T21CM05716
Permit Status: Issued
Permit Description: (T20DV02355) Rehab of existing structures based on damage from previous owners. No new expansion. E
Date Description Comments
05/01/2023 Masonry Inspection Report submittal review is required.

Outstanding Inspections

Permit Status: Issued
Permit Number: T21CM05716
Permite Description: (T20DV02355) Rehab of existing structures based on damage from previous owners. No new expansion. E
Total Outstanding Inspections - 15
Last Inspection Date Description Inspector Results Comments
10/26/2022 COT - FCON - Alarm - Final N/A Not Ready
10/26/2022 COT - FCON - Sprinkler - Final N/A Not Ready
10/26/2022 COT - LCBU - Sustainability N/A Not Ready
10/26/2022 COT - LCEL - Temporary Service N/A Not Ready
10/26/2022 COT - FCON - Fire - Final N/A Not Ready
10/26/2022 COT - LCBU - CofO N/A Not Ready
06/05/2023 COT - LCPL - Rough Soil N/A Partial Pass Partial pass. Unit #304 okay to back fill. Shading is required. 5/25/2023

Partial pass. #103 and #110 okay to backfill. Shading required. 5/30/2023
(Superintendent stated that Unit #110 is actually #106. Map was provided for verification)

Partial pass. Unit #101 and #102 okay to backfill. Shading is required. 6/5/23

Partial pass. Unit #104 and #105 okay to backfill. Shading is required. 6/5/23
12/05/2023 COT - LCEL - Electrical Intermediate N/A Partial Pass Partial pass. MEP'S units 104, 105, 107, and 108. Okay to proceed progress areas. 12/5/2023
02/07/2024 COT - LCBU - Building Progress N/A Partial Pass 2/7/2024. Rough in intermediate (MEP'S) approved for unit #301. Drywall nailing for #302 and #303 approved. Okay to proceed progress areas.

Units 101, 102, 104, 105, 107, 108, 201, and 202. Drywall inspection. Okay to proceed progress areas. 1/17/24
12/08/2023 COT - LCME - Mechanical Intermediate N/A Partial Pass 12/08/23: 101,102, 104,105,107,108 all partial for intermediates
12/08/2023 COT - LCPL - Plumbing Intermediate N/A Partial Pass 12/08/23: 101,102, 104,105,107,108 all partial for intermediates
10/26/2022 COT - LCEL - Grounding/Bonding N/A Not Ready
10/26/2022 COT - LCME - Mechanical Final N/A Not Ready
10/26/2022 COT - LCPL - Plumbing Final N/A Not Ready
08/06/2024 BULD - Electrical Clearance N/A Partial Pass Ok for clearance for units 101,102,103,104,105,106,107,108,109,110, 201 and 202 and house panel

Completed Inspections

Permit Status: Issued
Permit Number: T21CM05716
Permit Description: (T20DV02355) Rehab of existing structures based on damage from previous owners. No new expansion. E
Total Completed Inspections - 24
Date Description Inspector Results Comments
06/01/2023 COT - LCEL - Electrical Underground Passed
06/13/2023 COT - LCBU - Excavation/Rebar/Zoning Passed
06/13/2023 COT - LCBU - Preslab Passed
06/20/2023 COT - HCPL - Rough Soil Passed Duplicate of Light commercial permit
06/23/2023 COT - LCPL - Rough Soil Passed 6-23-23. Rough soil complete in building 3. Okay to backfill and pour concrete back.
06/23/2023 COT - LCBU - Framing Passed Rough framing for buildings 1, 2, & 3 is complete. Okay to insulate, sheet rock, tape, & texture walls.
06/23/2023 COT - LCBU - Exterior Clips/Sheathing Passed Buildings 201, 202, 301, 302, 303, & 304 have H2.5 clips on each rafter.
06/23/2023 COT - LCBU - Roof Nailing Passed Buildings 301, 302, 303, & 304 have roof sheathing properly nailed off.
07/07/2023 COT - LCBU - Firewall/Fire Barrier/Firestop Passed All deficiencies have been corrected. Ok to cover areas in question.
03/18/2024 COT - LCEL - Electrical Intermediate Passed
03/18/2024 COT - LCBU - Building Progress Passed
03/18/2024 COT - LCME - Mechanical Intermediate Passed
03/19/2024 COT - HCPL - Sewer Passed
03/19/2024 COT - LCBU - Building Above Ceiling Passed
03/19/2024 COT - LCPL - Plumbing Intermediate Passed
03/19/2024 COT - HCBU - Exterior Clips/Sheathing Passed
06/11/2024 COT - HCBU - Interior Shear Bracing Passed
06/11/2024 COT - HCEL - Electrical Intermediate Passed Approved intermediates for unit #106,#301, and #304, okay to cover progress areas
07/08/2024 COT - LCEL - Construction Power Passed
07/08/2024 COT - LCEL - Grounding/Bonding Passed
07/24/2024 COT - LCBU - Building Final Passed Approved all finals - units #101-#108 , units #201, #202 , and units #302, #303
07/24/2024 COT - LCEL - Electrical Final Passed Approved all finals - units #101-#108 , units #201, #202 , and units #302, #303
07/24/2024 COT - LCME - Mechanical Final Passed Approved all finals - units #101-#108 , units #201, #202 , and units #302, #303
07/24/2024 COT - LCPL - Plumbing Final Passed Approved all finals - units #101-#108 , units #201, #202 , and units #302, #303

Documents

File Name Document Type  
APPLICATION.PDF DOCUMENTS VIEW
DZ BOND CONTINUATION.PDF DOCUMENTS VIEW
ELECTRICAL PLANS.PDF DOCUMENTS VIEW
GCL.PDF DOCUMENTS VIEW
JOB CARD.PDF DOCUMENTS VIEW
MAN J CALCS.PDF DOCUMENTS VIEW
PERMIT.PDF DOCUMENTS VIEW
PLAN SET.PDF DOCUMENTS VIEW
TERRACON GROUT SAMPLING REPORT_V1.PDF DOCUMENTS VIEW
TERRACON OBSERVATION REPORT_V1.PDF DOCUMENTS VIEW
TERRACON 1_V1.PDF DOCUMENTS VIEW
244 W FLORES TRUSS DRAWING STAMPED_SSE REVIEWED_V1.PDF DOCUMENTS VIEW
COFT - PDSD - PERMIT CARD.PDF DOCUMENTS VIEW
2_SIC 2022-06-03 - UPLOADED FILE TYPE PLANS 1-2023-02-09_V1.PDF DOCUMENTS VIEW
CONS-2_RAH FLORES CD REV 1 2023-02-15_V2.PDF DOCUMENTS VIEW
3_COMMENT RESPONSE_V1.PDF DOCUMENTS VIEW
CONS-3_PLAN SET_V1.PDF DOCUMENTS VIEW
COFT - PDSD - PERMIT CARD.PDF DOCUMENTS VIEW