Permit Review Detail
Review Status: Completed
Review Details: REVISION - - 1ST
Permit Number - T21CM05716
Review Name: REVISION - - 1ST
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 04/13/2022 | ERIC NEWCOMB | BUILDING-COMMERCIAL | REVIEW | Reqs Change | 1. Sheet g0.05 (Life Safety Plan); Sheet as1.01 (Site Plan): Please coordinate the north arrows on these plans and on the individual unit plans. 2. Sheet a1.03; Enlarged Unit Plan 3: Please indicate on the plan the new wall indicated on the north side of the unit should be Wall Type W-04. 3. Sheet a1.04; Enlarged Unit Plan 3: Please indicate the rated wall on the north side of the unit and add a W-04 Wall Tag. 4. General: Please provide a Special Inspections Certificate with Parts A and B completed. 5. General: Please provide written responses to all review comments. |
| 04/20/2022 | JVINCEN1 | FIRE | REVIEW | Approved | |
| 04/20/2022 | SSHIELD1 | ENGINEERING | REVIEW | Reqs Change | See Zoning comments |
| 04/20/2022 | STEVE SHIELDS | ZONING | REVIEW | Denied | ZONING REVIEW TRANSMITTAL FROM: PDSD Zoning Review PROJECT: T21CM05716 244 W Flores St – C-2 Revision to add additional units TRANSMITTAL: April 20, 2022 resubmit revised drawings and a detailed response letter, which states how all Zoning Review Section comments were addressed. This site is located in the C-2 zone (UDC 4.7.21). A Multifamily Development is a permitted use in this zone (Table 4.8-4). 1. Per UDC Article 3.3.3.G.2.c A site plan (Development Package) is required for the following types of development: Existing development undergoing a change of use, building structure additions, and/or a reconfiguration of an area outside a building. A development package (DP) meeting the requirements of Administrative Manual (AM) 2-06 must be submitted and approved prior to approval of this building plan. The DP is a separate submittal from the building plans and is submitted at: https://docs.tucsonaz.gov/Forms/tucsonpermitapp, using Submission Type “Site Review”. If you have any questions about this transmittal, please contact Nicholas Ross at Nocholas.Ross@tucsonaz.gov. |
| 04/27/2022 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Reqs Change | 1. Specify that all owner-specified plumbing fixtures shall be listed by a third-party certification agency as complying with the relevant standards. Reference: Section 303.4, IPC 2018. 2. Remark #3 of the plumbing fixture schedule refers to an ADA water closet. Where are these located? Reference: Section 107.2.1, IBC 2018. 3. Provide keynotes 8, 9, and 10 for sheet p1.02. Reference: Section 107.2.1, IBC 2018. 4. The residential provisions of the 2018 International Energy Compliance Code are the controlling energy code requirement for this project (e.g. see the Water Heater System Schedule). Reference: Sections R101.5 and R501.1, IECC 2018. 5. All of the partial waste & vent isometrics on p1.02 and p2.02 are labeled as partial water isometrics. 6. If the showers do not have prefabricated receptors, provide details to show that the construction of the receptors complies with the requirements of Section 421.5, IPC 2018. 7. Provide shower valves that comply with the requirements of Section 412.3, IPC 2018. 8. Provide a detail showing that the water heaters located above the ceilings will have adequate access and maintenance space. Reference: Sections 502.3 and 502.5, IPC 2018 and Article 210.70 (c), NEC 2017. |
| 04/27/2022 | ROBERT SHERRY | WATER | REVIEW | Passed | |
| 04/28/2022 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Reqs Change | 1. Provide guards for equipment located within 10 feet of a roof edge or of a walking surface that is elevated more than 30 inches above the adjoining grade. Reference: Section 304.11, IMC 2018. 2. Ventilation for kitchens in private dwellings requires a minimum of 25 CFM (continuous operation) or 100 CFM (intermittent operation) of mechanical exhaust per room with no recirculation of air (e.g. specify the exhaust flowrate for the kitchen hood). Reference: Table 403.3.2.3, IMC 2018. |
| 05/05/2022 | DAN SANTA CRUZ | ELECTRICAL-COMMERCIAL | REVIEW | Reqs Change | Please address the electrical plan review comments and provide a written response. 1 . For clarity, please provide more detail on the plans pertaining to electrical revisions. Clouds or Deltas in reference to all the changes on the electrical plans. The narrative letter submitted did not disclose this information. Ref; 2018 IBC sec 107.2.1, 2017 NEC, 2018 IECC. 2012 Tucson/Pima County Outdoor Lighting Code, City of Tucson Commercial Plan Submittal Requirements. |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 05/06/2022 | VVERA1 | OUT TO CUSTOMER | Completed |