Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
Expired
Type:
Commercial Building
Address:
4112 E GRANT RD
Address NEW:
4112 E GRANT RD
Apply Date:
01/13/2021
Applicant:
Steven Shell
Description:
Construct a new exterior wall to replace the entire North end of the building scheduled to be remove

Permit Reviews

Permit Number - T21CM00368
Permit Status: Expired
Permit Description: Construct a new exterior wall to replace the entire North end of the building scheduled to be remove
Start Date Submittal Complete Date Status  
01/13/2021 COMMERCIAL - TI 02/10/2021 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T21CM00368
Permit Status: Expired
Permit Description: Construct a new exterior wall to replace the entire North end of the building scheduled to be remove
Total Outstanding Activity Conditions - 4
Date Name
02/10/2021 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.
02/10/2021 SPECIAL INSPECTION FORMS AND REPORTS REQUIRED PRIOR TO ISSUANCE OF A CERTIFICATE OF OCCUPANCY.
02/10/2021 SPECIAL INSPECTION FOR STRUCTURAL MASONRY IS REQUIRED.
02/10/2021 SPECIAL INSPECTION FOR EXPANSION ANCHORS IS REQUIRED.

Outstanding Inspections

Permit Status: Expired
Permit Number: T21CM00368
Permite Description: Construct a new exterior wall to replace the entire North end of the building scheduled to be remove
Total Outstanding Inspections - 6
Last Inspection Date Description Inspector Results Comments
05/17/2021 COT - LCEL - Electrical Intermediate N/A Canceled {Activity date: 05/17/2021; Status: Not Applicable; Inspector: ESTEVENS; Comment: Entered by VLEON1 - }
05/17/2021 COT - LCME - Mechanical Final N/A Canceled {Activity date: 05/17/2021; Status: Not Applicable; Inspector: ESTEVENS; Comment: Entered by VLEON1 - }
05/17/2021 COT - LCEL - Construction Power N/A Canceled {Activity date: 05/17/2021; Status: Not Applicable; Inspector: ESTEVENS; Comment: Entered by VLEON1 - } ; {Activity date: 03/15/2021; Status: Not ready for Inspection; Inspector: ESTEVENS; Comment: Entered by VLEON1 - }
05/17/2021 COT - LCPL - Rough Soil N/A Canceled {Activity date: 05/17/2021; Status: Not Applicable; Inspector: ESTEVENS; Comment: Entered by VLEON1 - }
05/17/2021 COT - LCPL - Plumbing Final N/A Canceled {Activity date: 05/17/2021; Status: Not Applicable; Inspector: ESTEVENS; Comment: Entered by VLEON1 - }
11/07/2022 COT - LCEL - Temporary Service N/A Canceled Inspection Canceled

Completed Inspections

Permit Status: Expired
Permit Number: T21CM00368
Permit Description: Construct a new exterior wall to replace the entire North end of the building scheduled to be remove
Total Completed Inspections - 12
Date Description Inspector Results Comments
02/18/2021 COT - LCBU - Excavation/Rebar/Zoning Passed {Activity date: 02/18/2021; Status: Approved; Inspector: DQUINN; Comment: Entered by RSALDAT1 - Ap
North wall ok to pour}
02/18/2021 COT - LCEL - Grounding/Bonding Passed {Activity date: 02/18/2021; Status: Approved; Inspector: DQUINN; Comment: Entered by RSALDAT1 - Ap}
03/15/2021 COT - LCBU - Framing Passed {Activity date: 03/15/2021; Status: Approved; Inspector: ESTEVENS; Comment: Entered by VLEON1 - } ; {Activity date: 03/04/2021; Status: Partial Approval; Inspector: TGAUSP; Comment: Entered by BSTEVENS - APPROVED TO NEW CMU WALL OK TO ROOF} ; {Activity date: 02/26/2021; Status: Partial Approval; Inspector: ESTEVENS; Comment: Entered by BSTEVENS - PARTIAL LEDGER BOLTS IN PLACE}
03/15/2021 COT - LCBU - Roof Nailing Passed {Activity date: 03/15/2021; Status: Approved; Inspector: ESTEVENS; Comment: Entered by VLEON1 - }
03/26/2021 COT - LCBU - Masonry Pregrout Passed {Activity date: 03/26/2021; Status: Approved; Inspector: BSTEVENS; Comment: Entered by BSTEVENS - OK TO TOP OF WALL} ; {Activity date: 03/01/2021; Status: Partial Approval; Inspector: DQUINN; Comment: Entered by BSTEVENS - PARTIAL - North wall ok to grout to top. Verts and horizontals for bond and ledger bolts ok} ; {Activity date: 02/26/2021; Status: Approved; Inspector: ESTEVENS; Comment: Entered by BSTEVENS - PARTIAL GROUT 4TH LIFT 12 TO 16 FEET} ; {Activity date: 02/25/2021; Status: Partial Approval; Inspector: KCOCO; Comment: Entered by BSTEVENS - PARTIAL APPROVAL FOR NORTH WALL 3RD LIFT} ; {Activity date: 02/24/2021; Status: Cancelled; Inspector: ESTEVENS; Comment: Entered by VLEON1 - CANCELLED BY CONTRACTOR} ; {Activity date: 02/23/2021; Status: Partial Approval; Inspector: KCOCO; Comment: Entered by BSTEVENS - FIRST LIFT TO BOND BEAM AT TOP OF STEM AND AT WINDOW SILLS.
2ND LIFT FOR NORTH WALL ONLY}
03/30/2021 PDSD Building Division - TEP PM Clearance Passed {Activity date: 03/30/2021; Status: Approved; Inspector: RELEFANTE; Comment: Entered by VLEON1 - CODE RECN}
03/30/2021 COT - LCEL - Electrical Reconnect Passed {Activity date: 03/30/2021; Status: Approved; Inspector: RELEFANTE; Comment: Entered by VLEON1 - } ; {Activity date: 03/26/2021; Status: Cancelled; Inspector: IVR USER; Comment: Entered by IVR USER - IVRS - AP canceled} ; {Activity date: 03/15/2021; Status: Not Applicable; Inspector: ESTEVENS; Comment: Entered by VLEON1 - }
05/17/2021 COT - LCBU - Building Final Passed {Activity date: 05/17/2021; Status: Approved; Inspector: ESTEVENS; Comment: Entered by VLEON1 - }
05/17/2021 COT - LCBU - Preslab Passed {Activity date: 05/17/2021; Status: Approved; Inspector: ESTEVENS; Comment: Entered by VLEON1 - APPROVED BY DAN QUINN ON FEBRUARY 18, 2021}
05/17/2021 COT - LCEL - Electrical Final Passed {Activity date: 05/17/2021; Status: Approved; Inspector: ESTEVENS; Comment: Entered by VLEON1 - }
05/17/2021 COT - LCBU - Building Progress Passed {Activity date: 05/17/2021; Status: Approved; Inspector: ESTEVENS; Comment: Entered by VLEON1 - } ; {Activity date: 05/14/2021; Status: Cancelled; Inspector: IVR USER; Comment: Entered by IVR USER - IVRS - AP canceled} ; {Activity date: 03/15/2021; Status: Not Applicable; Inspector: ESTEVENS; Comment: Entered by VLEON1 - }
05/18/2021 COT - FCON - Fire - Final Passed {Activity date: 05/18/2021; Status: Approved; Inspector: MRoss; Comment: Entered by MROSS2 - } ; {Activity date: 05/17/2021; Status: Partial Approval; Inspector: MRoss; Comment: Entered by MROSS2 - -Provide and mount fire extinguisher, minimum size 2A 10BC
-Repair or remove non working exit signs.}

Documents

File Name Document Type  
APPLICATION.PDF DOCUMENTS VIEW
PERMIT.PDF DOCUMENTS VIEW
JOB CARD.PDF DOCUMENTS VIEW
PLAN SET.PDF CONSTRPLANS VIEW