Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Expired
Type:
Sign - Permanent
Address:
901 E 46TH ST
Address NEW:
901 E 46TH ST
Apply Date:
01/09/2020
Applicant:
Michael Trotter
Description:
Proposal to replace nonconforming freeway sign with a pole sign at 20' tall and 96 square feet sign

Outstanding Activity Conditions

Permit Number - T20OT00033
Permit Status: Expired
Permit Description: Proposal to replace nonconforming freeway sign with a pole sign at 20' tall and 96 square feet sign
Total Outstanding Activity Conditions - 2
Date Name
08/31/2020 SPECIAL INSPECTION FOR HIGH STRENGTH BOLTING IS REQUIRED.
08/31/2020 SIGN FOOTER SIZE AND FOUNDATION

Outstanding Inspections

Permit Status: Expired
Permit Number: T20OT00033
Permite Description: Proposal to replace nonconforming freeway sign with a pole sign at 20' tall and 96 square feet sign
Total Outstanding Inspections - 1
Last Inspection Date Description Inspector Results Comments
04/28/2021 SPECIAL INSPECTION - Sign Footing (Third Party) N/A Complete (Recurring) {Activity date: 04/28/2021; Status: Continued; Inspector: hthrall1; Comment: Entered by HTHRALL1 - Dave - need height / setback checked. Allowed per SDRC case MSP 20-001 Decision Notice (online):

1) Allow a pole sign at an increased sign area from 72 to 95.92 total square feet display area. (UDC 7A.10.2.C)

2) Allow a pole sign at an increased height of 20’, and taken from sign base to top of cabinet. (UDC 7A.10.2.C & 7A.6.5.)

3) Allow a pole sign at a reduced setback of 20’ from face of curb of Benson Highway.(UDC 7A.10.2.C.).} ; {Activity date: 04/28/2021; Status: Continued; Inspector: hthrall1; Comment: Entered by HTHRALL1 - Recevied special inspection certificate 4/28/21. Sealed by engineer Jason Wells on 4/26/21 that Justin Manchester has perfofrmed the drilled pier special inspection as of October 2, 2020 that 3' x 12' diameter and depth was confirmed.

Further - on 4/26/21, Justin Manchester provided report to engineer Wells that the hi-strength bolting was completed on 4/26/21 - "bolting at all levels B7 (3/4") all thread rod was used with a flat washer, lock washer, and 3/4" hex nut. Connections were tightened to a snug tight condition at all locations.

Both reports and S.I. sealed certificate were added to online file. Consulted and received permission from Eric Newcomb to sign off on returned / sealed S.I. certificate. H. Thrall} ; {Activity date: 03/31/2021; Status: Continued; Inspector: Hthrall; Comment: Entered by HTHRALL1 - } ; {Activity date: 08/31/2020; Status: Continued; Inspector: hthrall; Comment: Entered by HTHRALL1 - INSPECTOR - SPECIAL INSPECTION REQUIRED FOR FOOTER / FOUNDATION.

NEEDS A SETBACK CHECK (20' PER SDRC CASE / PLANS)
NEEDS A HEIGHT CHECK (20' PER SDRC CASE / PLANS - TO TOP OF HIGHEST CABINET)}

Completed Inspections

Permit Status: Expired
Permit Number: T20OT00033
Permit Description: Proposal to replace nonconforming freeway sign with a pole sign at 20' tall and 96 square feet sign
Total Completed Inspections - 2
Date Description Inspector Results Comments
07/12/2021 COT - ENGR - Sign Electrical Passed {Activity date: 07/12/2021; Status: Approved; Inspector: DROBERTS; Comment: Entered by RSALDAT1 - APPROVED} ; {Activity date: 03/31/2021; Status: Continued; Inspector: Hthrall; Comment: Entered by HTHRALL1 - } ; {Activity date: 08/31/2020; Status: Continued; Inspector: hthrall; Comment: Entered by HTHRALL1 - INSPECTOR - PLEASE SEE CONTROL FOR DIGITAL SIGN HAS SETTING AT 1 CHANGE PER MINUTE MAXIMUM, NO ANIMATION, DIMS TO 200 NITS FROM SUNDOWN TO CURFEW OF MIDNIGHT.}
07/12/2021 COT - ENGR - Signage Final Passed {Activity date: 07/12/2021; Status: Approved; Inspector: DROBERTS; Comment: Entered by RSALDAT1 - APPROVED} ; {Activity date: 05/28/2021; Status: Not ready for Inspection; Inspector: DROBERTS; Comment: Entered by VLEON1 - NOT READY AT THIS TIME.
CHECK THE OFFSET FOR ACCURACY FOR THE SETBACK AND CHANGE THE TIMING FOR THE EMS, NO MORE THAN ONCE A MINUTE FOR THE CHANGING OF FRAMES} ; {Activity date: 03/31/2021; Status: Continued; Inspector: Hthrall; Comment: Entered by HTHRALL1 - } ; {Activity date: 08/31/2020; Status: Continued; Inspector: hthrall; Comment: Entered by HTHRALL1 - INSPECTOR - PLEASE DO NOT FINAL UNTIL SPECIAL INSPECTIONS ARE COMPLETED.}

Documents

File Name Document Type  
T20OT00033_RETURNED 4-26-21_SPEC INSP CERT SEALED_ PPEP_901 E 46TH_AUG 2020.PDF SIGNS VIEW
T20OT00033_PPEP INTEGRATED CARE SIGN, S.I. REPORT, 10-2-2020.PDF SIGNS VIEW
T20OT00033_PPEP INTEGRATED CARE SIGN, S.I. REPORT, 4-26-21.PDF SIGNS VIEW
T19OT00033_PERMIT APPLICATION.PDF SIGNS VIEW
T20OT0033_PPEP 901 DRAWINGS & ENGINEERING_AUG 2020.PDF SIGNS VIEW
T20OT00033_ELECTRIC AND SETBACK PLANS_MSP-20-001.PDF SIGNS VIEW
T20OT00033_SPEC INSP CERT SEALED_ PPEP_901 E 46TH_AUG 2020.PDF SIGNS VIEW
T20OT00033_PPEP_SURVEY DRAWING_1.PDF SIGNS VIEW
T20OT00033_REFERENCE_MSP-20-001 DECISION T20SA00026 901 E 46TH ST.PDF SIGNS VIEW
T20OT00033_SIGN PERMIT_901 E 46TH_PPEP POLE SIGN.PDF SIGNS VIEW