Outstanding Activity Conditions
Permit Number - T20OT00033
Permit Status: Expired
Permit Description: Proposal to replace nonconforming freeway sign with a pole sign at 20' tall and 96 square feet sign
Total Outstanding Activity Conditions - 2
| Date | Name |
|---|---|
| 08/31/2020 | SPECIAL INSPECTION FOR HIGH STRENGTH BOLTING IS REQUIRED. |
| 08/31/2020 | SIGN FOOTER SIZE AND FOUNDATION |
Outstanding Inspections
Permit Status: Expired
Permit Number: T20OT00033
Permite Description: Proposal to replace nonconforming freeway sign with a pole sign at 20' tall and 96 square feet sign
Total Outstanding Inspections - 1
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/28/2021 | SPECIAL INSPECTION - Sign Footing (Third Party) | N/A | Complete (Recurring) | {Activity date: 04/28/2021; Status: Continued; Inspector: hthrall1; Comment: Entered by HTHRALL1 - Dave - need height / setback checked. Allowed per SDRC case MSP 20-001 Decision Notice (online): 1) Allow a pole sign at an increased sign area from 72 to 95.92 total square feet display area. (UDC 7A.10.2.C) 2) Allow a pole sign at an increased height of 20’, and taken from sign base to top of cabinet. (UDC 7A.10.2.C & 7A.6.5.) 3) Allow a pole sign at a reduced setback of 20’ from face of curb of Benson Highway.(UDC 7A.10.2.C.).} ; {Activity date: 04/28/2021; Status: Continued; Inspector: hthrall1; Comment: Entered by HTHRALL1 - Recevied special inspection certificate 4/28/21. Sealed by engineer Jason Wells on 4/26/21 that Justin Manchester has perfofrmed the drilled pier special inspection as of October 2, 2020 that 3' x 12' diameter and depth was confirmed. Further - on 4/26/21, Justin Manchester provided report to engineer Wells that the hi-strength bolting was completed on 4/26/21 - "bolting at all levels B7 (3/4") all thread rod was used with a flat washer, lock washer, and 3/4" hex nut. Connections were tightened to a snug tight condition at all locations. Both reports and S.I. sealed certificate were added to online file. Consulted and received permission from Eric Newcomb to sign off on returned / sealed S.I. certificate. H. Thrall} ; {Activity date: 03/31/2021; Status: Continued; Inspector: Hthrall; Comment: Entered by HTHRALL1 - } ; {Activity date: 08/31/2020; Status: Continued; Inspector: hthrall; Comment: Entered by HTHRALL1 - INSPECTOR - SPECIAL INSPECTION REQUIRED FOR FOOTER / FOUNDATION. NEEDS A SETBACK CHECK (20' PER SDRC CASE / PLANS) NEEDS A HEIGHT CHECK (20' PER SDRC CASE / PLANS - TO TOP OF HIGHEST CABINET)} |
Completed Inspections
Permit Status: Expired
Permit Number: T20OT00033
Permit Description: Proposal to replace nonconforming freeway sign with a pole sign at 20' tall and 96 square feet sign
Total Completed Inspections - 2
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/12/2021 | COT - ENGR - Sign Electrical | Passed | {Activity date: 07/12/2021; Status: Approved; Inspector: DROBERTS; Comment: Entered by RSALDAT1 - APPROVED} ; {Activity date: 03/31/2021; Status: Continued; Inspector: Hthrall; Comment: Entered by HTHRALL1 - } ; {Activity date: 08/31/2020; Status: Continued; Inspector: hthrall; Comment: Entered by HTHRALL1 - INSPECTOR - PLEASE SEE CONTROL FOR DIGITAL SIGN HAS SETTING AT 1 CHANGE PER MINUTE MAXIMUM, NO ANIMATION, DIMS TO 200 NITS FROM SUNDOWN TO CURFEW OF MIDNIGHT.} | |
| 07/12/2021 | COT - ENGR - Signage Final | Passed | {Activity date: 07/12/2021; Status: Approved; Inspector: DROBERTS; Comment: Entered by RSALDAT1 - APPROVED} ; {Activity date: 05/28/2021; Status: Not ready for Inspection; Inspector: DROBERTS; Comment: Entered by VLEON1 - NOT READY AT THIS TIME. CHECK THE OFFSET FOR ACCURACY FOR THE SETBACK AND CHANGE THE TIMING FOR THE EMS, NO MORE THAN ONCE A MINUTE FOR THE CHANGING OF FRAMES} ; {Activity date: 03/31/2021; Status: Continued; Inspector: Hthrall; Comment: Entered by HTHRALL1 - } ; {Activity date: 08/31/2020; Status: Continued; Inspector: hthrall; Comment: Entered by HTHRALL1 - INSPECTOR - PLEASE DO NOT FINAL UNTIL SPECIAL INSPECTIONS ARE COMPLETED.} |