Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: T20CM06675
Permit Details
Apply Date:
09/25/2020
Applicant:
SCOTT FELTHEIM
Description:
NEW METAL BUILDING WITH CHURCH SANCTUARY, WASHROOMS AND OFFICES
Architects:
- FELTHEIM SCOTT
Contractors:
- KAPPCON INC
Permit Reviews
Permit Number - T20CM06675
Permit Status: Final
Permit Description: NEW METAL BUILDING WITH CHURCH SANCTUARY, WASHROOMS AND OFFICES
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
01/21/2021 | RESUBMITTAL | 03/01/2021 | COMPLETED |
05/17/2021 | 3RD PARTY REVIEW - REVISION/OTHER | 08/12/2021 | COMPLETED |
09/18/2020 | COMMERCIAL - NEW | 11/10/2020 | COMPLETED |
11/16/2020 | RESUBMITTAL | 12/17/2020 | COMPLETED |
Completed Inspections
Permit Status: Final
Permit Number: T20CM06675
Permit Description: NEW METAL BUILDING WITH CHURCH SANCTUARY, WASHROOMS AND OFFICES
Total Completed Inspections - 47
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
01/25/2021 | STEM WALL/RETAINING WALL | TTREMBULAK | Approved | APPROVED |
03/18/2021 | EXCAVATION/LAYOUT REBAR & ZON | DMUNIZ | Approved | Partial, GL-Q exterior footing, 10 spread footings for building columns, 11 caisson footings for shade structure all ok for concrete placement. |
05/12/2021 | MECHANICAL - ABOVE CEILING | TTREMBULAK | Approved | |
05/12/2021 | ELECTRIC - ABOVE CEILING | TTREMBULAK | Approved | |
07/06/2021 | BUILDING PRE-SLAB | DMUNIZ | Approved | Approved |
07/23/2021 | PLUMBING - INTERMEDIATE | TGAUSP | Approved | Approved, all copper waterlines and DWV and Baptistry. |
08/05/2021 | FRAMING | RELEFANTE | Approved | AP |
08/11/2021 | GAS CLEARANCE | TGAUSP | Approved | CODE |
08/11/2021 | PLUMBING - GAS PRESSURE TEST | TGAUSP | Approved | Approved, please send clearance to SWG for meter set |
08/20/2021 | PLUMBING - YARD WTR LINE/TEST | DMUNIZ | Approved | Approved |
08/20/2021 | PLUMBING - ROUGH, SOIL | DMUNIZ | Approved | Approved |
08/24/2021 | SHEET ROCK NAILING | DMUNIZ | Approved | Approved |
08/26/2021 | MECHANICAL - INTERMEDIATE | DMUNIZ | Approved | Approved |
08/26/2021 | U VALUE FOR WINDOW | DMUNIZ | Approved | Approved |
08/27/2021 | PLUMBING - MD GAS/PRECONST MTG | DMUNIZ | Approved | Not Applicable. |
08/27/2021 | ELECTRIC - CABLE DROP | DMUNIZ | Approved | Not Applicable. |
08/27/2021 | SITE - SEWER | DMUNIZ | Approved | Approved |
08/27/2021 | PLUMBING - ABOVE CEILING | DMUNIZ | Approved | Approved |
08/27/2021 | PLUMBING - PRE SLAB | DMUNIZ | Approved | Approved |
08/27/2021 | ELECTRIC - INTERMEDIATE | DMUNIZ | Approved | Approved |
08/27/2021 | EXT METAL CLIPS/EXT SHEATHING | DMUNIZ | Approved | Approved |
09/22/2021 | ROOF NAILING | DMUNIZ | Approved | Approved |
09/23/2021 | ELECTRIC - CONSTRUCTION POWER | DMUNIZ | Approved | Approved, Clear TEP ECO (2950 E IRVINGTON RD, BUILDING 2) |
09/23/2021 | ELECTRIC - UNDERGROUND | DMUNIZ | Approved | Approved |
09/23/2021 | ELECTRIC - UFER | DMUNIZ | Approved | Approved |
09/28/2021 | TEP CLEARANCE - PM | TGAUSP | Approved | CODE INCR/POWERKILL/BUILD 1 AND SHED (METER #159477361) |
09/28/2021 | ELECTRIC - SERVICE UPGRADE | TGAUSP | Approved | Approved, INCR Clearance was called into TEP (Powerkill) for Bldg #1 and Shed (meter# 159477361) |
10/05/2021 | ELECTRIC - OUTDOOR LIGHTING | TGAUSP | Approved | - Approved foundation and uffer, okay to pour |
10/19/2021 | BUILDING ABOVE CEILING | TGAUSP | Approved | Approved |
10/21/2021 | OUTDOOR LIGHTING FINAL | DMUNIZ | Approved | Approved |
10/21/2021 | PLUMBING - GAS PRESS TEST FNL | DMUNIZ | Approved | Approved |
10/27/2021 | RIGHT OF WAY - FINAL | AF | Approved | |
10/28/2021 | FIRE - ALARM FINAL | MRoss | Approved | -Need to verify A/V shutdown -Test front lobby microphone at annunciator panel -Need to test HVAC shutdown for units inside the building |
10/28/2021 | MECHANICAL - FINAL | RSHERRY | Approved | REVIEW OF AIR BALANCE REPORT COMPLETED |
10/28/2021 | ENGINEERING - FINAL | DROBERTS | Approved | IS PARTIAL, OK FOR TCO |
10/28/2021 | MECHANICAL - FINAL | DMUNIZ | Approved | PARTIAL, submit AIR balance report for review. |
10/28/2021 | ELECTRIC - FINAL | DMUNIZ | Approved | Approved |
10/29/2021 | PLUMBING - FINAL | DMUNIZ | Approved | APPROVED |
10/29/2021 | FIRE - FINAL | wmotto1 | Approved | 1. Ok to TCO per tucson fire. remaining hvac untits tested and passed. |
10/29/2021 | FIRE SPKLR - OH PIPING & HYDRO | wmotto1 | Approved | |
10/29/2021 | FIRE SPKLR - UG PIPING FLUSH | wmotto1 | Approved | |
10/29/2021 | FIRE SPKLR - UG, PIPING, HYDRO | wmotto1 | Approved | |
12/01/2021 | FIRE SPKLR - FINAL | MRoss | Approved | |
12/14/2021 | SIGN - FINAL | DROBERTS | Approved | |
12/14/2021 | LANDSCAPE - FINAL | DROBERTS | Approved | |
12/14/2021 | NPPO - FINAL | DROBERTS | Approved | |
12/15/2021 | BUILDING - FINAL | DMUNIZ | Approved | Partial, Final COfO pending Engineering and Fire Final approvals. |