Description:
GAS RECONNECT

Outstanding Activity Conditions

Permit Number - T19CM09345
Permit Status: Final
Permit Description: GAS RECONNECT
Total Outstanding Activity Conditions - 1
Date Name
12/19/2019 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: Final
Permit Number: T19CM09345
Permit Description: GAS RECONNECT
Total Completed Inspections - 4
Date Description Inspector Results Comments
12/27/2019 PLUMBING - FINAL TVALENCIA Approved 1- The air pressure test gage was just above 2 psi. The pressure test shall be a minimum of 10 psi. Check the system for leaks.
2- Shall provide (3) sheet metal screws per joint on furnace flu vent and remove the mechanical tape around the vent connector to the double wall flu vent.
3- Shall remove the flex connector on the water heater t & p drain and terminate it 6 inches above the floor.
12/27/2019 PLUMBING - GAS RECONNECT TVALENCIA Approved 1- The air pressure test gage was just above 2 psi. The pressure test shall be a minimum of 10 psi. Check the system for leaks.
2- Shall provide (3) sheet metal screws per joint on furnace flu vent and remove the mechanical tape around the vent connector to the double wall flu vent.
3- Shall remove the flex connector on the water heater t & p drain and terminate it 6 inches above the floor.
12/27/2019 PLUMBING - GAS PRESSURE TEST TVALENCIA Approved 1- The air pressure test gage was just above 2 psi. The pressure test shall be a minimum of 10 psi. Check the system for leaks.
2- Shall provide (3) sheet metal screws per joint on furnace flu vent and remove the mechanical tape around the vent connector to the double wall flu vent.
3- Shall remove the flex connector on the water heater t & p drain and terminate it 6 inches above the floor.
01/06/2020 GAS CLEARANCE TVALENCIA Approved