Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
Expired
Type:
Residential Building - One or Two Family
Address NEW:
2864 N FAIR OAKS AV
Apply Date:
10/03/2019
Applicant:
Description:
NEW SFR: CORN150019 T19-M0094

Permit Reviews

Permit Number - T19CM07239
Permit Status: Expired
Permit Description: NEW SFR: CORN150019 T19-M0094
Start Date Submittal Complete Date Status  
10/03/2019 RESIDENTIAL - BLDG/ZONING-WALKTHRU 10/22/2019 COMPLETED Review Details
10/22/2019 REVISION - - 1ST 10/22/2019 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T19CM07239
Permit Status: Expired
Permit Description: NEW SFR: CORN150019 T19-M0094
Total Outstanding Activity Conditions - 2
Date Name
10/03/2019 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.
10/03/2019 SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED.

Conditions

Permit Number - T19CM07239
Permit Status: Expired
Permit Description: NEW SFR: CORN150019 T19-M0094
Date Description Comments
10/03/2019 ROOF TRUSSES MUST BE APPROVED PRIOR TO FRAMING INSPECTION (P2I)

Outstanding Inspections

Permit Status: Expired
Permit Number: T19CM07239
Permite Description: NEW SFR: CORN150019 T19-M0094
Total Outstanding Inspections - 2
Last Inspection Date Description Inspector Results Comments
12/19/2019 COT - LCPL - Plumbing Roof Drains N/A Canceled {Activity date: 12/19/2019; Status: Not Applicable; Inspector: RCHANDLER; Comment: Entered by DMERANZ1 - }
12/19/2019 RSPL - Plumbing Progress N/A Canceled {Activity date: 12/19/2019; Status: Not Applicable; Inspector: RCHANDLER; Comment: Entered by DMERANZ1 - }

Completed Inspections

Permit Status: Expired
Permit Number: T19CM07239
Permit Description: NEW SFR: CORN150019 T19-M0094
Total Completed Inspections - 24
Date Description Inspector Results Comments
10/08/2019 COT - RSPL - Rough Soil Passed {Activity date: 10/08/2019; Status: Approved; Inspector: JCLAXTON; Comment: Entered by DMERANZ1 - Ok to bury.}
10/23/2019 COT - RSBU - Preslab Passed {Activity date: 10/23/2019; Status: Approved; Inspector: RCHANDLER; Comment: Entered by DMERANZ1 - Fire walls added to resolve corrections.} ; {Activity date: 10/17/2019; Status: Correction Required; Inspector: RCHANDLER; Comment: Entered by DMERANZ1 - 1-The forms for this house will put the concrete six feet from the adjacent house; both walls are unrated with openings, which does not meet the requirements of IRC R Section R302.1 Exterior walls. REVISE Section by DELETING all text and tables (TABLE R302.1(1) EXTERIOR WALLS and TABLE R302.1(2) EXTERIOR WALLS-DWELLINGS WITH FIRE SPRINKLERS) and REPLACING with the following:
Exterior walls with a fire separation distance less than 3 feet (914mm) shall have not less than a one- hour fire-resistive rating with exposure from both sides. Projections shall not extend to a point closer than 2 feet (610 mm) from the line used to determine the fire separation distance. Projections extending into the fire separation distance shall have not less than one-hour fire-resistive construction on the underside. The above provisions shall not apply to walls which are perpendicular to the line used to determine the fire separation distance.}
10/23/2019 COT - RSBU - Excavation/Rebar/Zoning Passed {Activity date: 10/23/2019; Status: Approved; Inspector: RCHANDLER; Comment: Entered by DMERANZ1 - Note: Fire walls added to this lot due to being too close to property lines.} ; {Activity date: 10/17/2019; Status: Correction Required; Inspector: RCHANDLER; Comment: Entered by DMERANZ1 - 1-The forms for this house will put the concrete six feet from the adjacent house; both walls are unrated with openings, which does not meet the requirements of IRC R Section R302.1 Exterior walls. REVISE Section by DELETING all text and tables (TABLE R302.1(1) EXTERIOR WALLS and TABLE R302.1(2) EXTERIOR WALLS-DWELLINGS WITH FIRE SPRINKLERS) and REPLACING with the following:
Exterior walls with a fire separation distance less than 3 feet (914mm) shall have not less than a one- hour fire-resistive rating with exposure from both sides. Projections shall not extend to a point closer than 2 feet (610 mm) from the line used to determine the fire separation distance. Projections extending into the fire separation distance shall have not less than one-hour fire-resistive construction on the underside. The above provisions shall not apply to walls which are perpendicular to the line used to determine the fire separation distance.}
11/18/2019 COT - RSBU - Roof Nailing Passed {Activity date: 11/18/2019; Status: Approved; Inspector: RCHANDLER; Comment: Entered by DMERANZ1 - } ; {Activity date: 11/08/2019; Status: Not ready for Inspection; Inspector: DQUINN; Comment: Entered by DMERANZ1 - Need access to roof, preferably from inside 2nd floor.

}
11/27/2019 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Passed {Activity date: 11/27/2019; Status: Approved; Inspector: RCHANDLER; Comment: Entered by DMERANZ1 - Inspected via Face-Time. Per Builder and Inspection Supervisor openings can be recessed, and will be complete for inspection at intermediate.} ; {Activity date: 11/22/2019; Status: Correction Required; Inspector: RCHANDLER; Comment: Entered by DMERANZ1 - 1-Strap is not installed per approved plans.
2-Per Inspection manger, if window are not less than three feet from property line they can remain; installed window next door is 6’ 1/2" from rough frame of this house window opening. Combustion air openings are 5’ 9-1/2" apart, kitchen hood duct exhaust openings are 5’ 10" apart. Builder declines to obtain survey to determine where the property line is.
} ; {Activity date: 11/18/2019; Status: Correction Required; Inspector: RCHANDLER; Comment: Entered by DMERANZ1 - 1-Still need strap at top played.
2-Need revision for firewalls required on both sides.} ; {Activity date: 11/08/2019; Status: Denied; Inspector: DQUINN; Comment: Entered by DMERANZ1 - Missing rsp-4s on south wall studs, top and bottom.
Need continuity strap to tie angled roof top plates to blocking below the flat roof top plates. (SD2 #8) detail.
Check shear transfer nailing of between truss boxes, from roof and 2nd floor.}
12/19/2019 COT - RSEL - Grounding/Bonding Passed {Activity date: 12/19/2019; Status: Approved; Inspector: RCHANDLER; Comment: Entered by DMERANZ1 - }
12/19/2019 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Passed {Activity date: 12/19/2019; Status: Approved; Inspector: RCHANDLER; Comment: Entered by DMERANZ1 - }
12/19/2019 COT - LCBU - Framing Passed {Activity date: 12/19/2019; Status: Approved; Inspector: RCHANDLER; Comment: Entered by DMERANZ1 - } ; {Activity date: 11/22/2019; Status: Not ready for Inspection; Inspector: RCHANDLER; Comment: Entered by DMERANZ1 - Work incomplete. This should be scheduled when intermediate is ready.} ; {Activity date: 11/18/2019; Status: Correction Required; Inspector: RCHANDLER; Comment: Entered by DMERANZ1 - Need revision for fire wall required on both sides.}
12/19/2019 COT - LCPL - Plumbing Intermediate Passed {Activity date: 12/19/2019; Status: Approved; Inspector: RCHANDLER; Comment: Entered by DMERANZ1 - }
12/19/2019 COT - RSEL - Electrical Underground Passed {Activity date: 12/19/2019; Status: Approved; Inspector: RCHANDLER; Comment: Entered by DMERANZ1 - }
12/19/2019 RSME - Mechanical Progress Passed {Activity date: 12/19/2019; Status: Approved; Inspector: RCHANDLER; Comment: Entered by DMERANZ1 - }
12/31/2019 COT - RSBU - Firewall/Fire Barrier/Firestop Passed {Activity date: 12/31/2019; Status: Approved; Inspector: DQUINN; Comment: Entered by DMERANZ1 - }
01/17/2020 COT - HCBU - Interior Shear Bracing Passed {Activity date: 01/17/2020; Status: Approved; Inspector: ESTEVENS; Comment: Entered by ESTEVEN1 - IVR}
03/04/2020 COT - RSPL - Yard Water Line Passed {Activity date: 03/04/2020; Status: Approved; Inspector: RCHANDLER; Comment: Entered by DMERANZ1 - }
03/09/2020 COT - RSPL - Sewer Passed {Activity date: 03/09/2020; Status: Approved; Inspector: RCHANDLER; Comment: Entered by DMERANZ1 - }
03/10/2020 PDSD Building Division - TEP PM Clearance Passed {Activity date: 03/10/2020; Status: Approved; Inspector: RCHANDLER; Comment: Entered by DMERANZ1 - CODE ECO}
03/10/2020 COT - RSEL - Construction Power Passed {Activity date: 03/10/2020; Status: Approved; Inspector: RCHANDLER; Comment: Entered by DMERANZ1 - Clearance TEP eco}
03/11/2020 COT - BULD - SWG Clearance Passed {Activity date: 03/11/2020; Status: Approved; Inspector: RCHANDLER; Comment: Entered by SFLORES2 - }
04/01/2020 COT - RSPL - Plumbing Final Passed {Activity date: 04/01/2020; Status: Approved; Inspector: RCHANDLER; Comment: Entered by SFLORES2 - }
04/03/2020 COT - RSME - Mechanical Final Passed {Activity date: 04/03/2020; Status: Approved; Inspector: RCHANDLER; Comment: Entered by VFLORES1 - RVI}
04/03/2020 RSBU - Building Final Passed {Activity date: 04/03/2020; Status: Approved; Inspector: RCHANDLER; Comment: Entered by VFLORES1 - RVI} ; {Activity date: 04/01/2020; Status: Partial Approval; Inspector: RCHANDLER; Comment: Entered by SFLORES2 - RVI
Pending other inspections.} ; {Activity date: 03/11/2020; Status: Partial Approval; Inspector: RCHANDLER; Comment: Entered by SFLORES2 - Clearance for SW gas only. Ok to connect}
04/03/2020 COT - RSEL - Outdoor Lighting Passed {Activity date: 04/03/2020; Status: Approved; Inspector: RCHANDLER; Comment: Entered by VFLORES1 - RVI}
04/03/2020 COT - RSPL - Gas Pressure Test Passed {Activity date: 04/03/2020; Status: Approved; Inspector: RCHANDLER; Comment: Entered by VFLORES1 - RVI NO CLEARANCE NEEDED}
04/03/2020 COT - RSEL - Electrical Final Passed {Activity date: 04/03/2020; Status: Approved; Inspector: RCHANDLER; Comment: Entered by VFLORES1 - RVI} ; {Activity date: 04/01/2020; Status: Correction Required; Inspector: RCHANDLER; Comment: Entered by SFLORES2 - RVI
Lights at stairway are not working.
}

Documents

File Name Document Type  
None DOCUMENTS VIEW
None CONSTRPLANS VIEW