Inspection Status: Passed
Inspection History: COT - RSBU - Exterior/Interior Clips/Sheathing/Framing
Permit Number - T19CM07239
Inspection Description - COT - RSBU - Exterior/Interior Clips/Sheathing/Framing
Inspection Status - Passed
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/27/2019 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | RCHANDLER | Approved | Entered by DMERANZ1 - Inspected via Face-Time. Per Builder and Inspection Supervisor openings can be recessed, and will be complete for inspection at intermediate. |
| 11/22/2019 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | RCHANDLER | Correction Required | Entered by DMERANZ1 - 1-Strap is not installed per approved plans. 2-Per Inspection manger, if window are not less than three feet from property line they can remain; installed window next door is 6’ 1/2" from rough frame of this house window opening. Combustion air openings are 5’ 9-1/2" apart, kitchen hood duct exhaust openings are 5’ 10" apart. Builder declines to obtain survey to determine where the property line is. |
| 11/18/2019 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | RCHANDLER | Correction Required | Entered by DMERANZ1 - 1-Still need strap at top played. 2-Need revision for firewalls required on both sides. |
| 11/08/2019 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | DQUINN | Denied | Entered by DMERANZ1 - Missing rsp-4s on south wall studs, top and bottom. Need continuity strap to tie angled roof top plates to blocking below the flat roof top plates. (SD2 #8) detail. Check shear transfer nailing of between truss boxes, from roof and 2nd floor. |