Inspection Status: Passed
Inspection History: COT - RSBU - Exterior/Interior Clips/Sheathing/Framing
| Date |
Description |
Inspector |
Results |
Comments |
| 11/27/2019 |
COT - RSBU - Exterior/Interior Clips/Sheathing/Framing |
RCHANDLER |
Approved |
Entered by DMERANZ1 - Inspected via Face-Time. Per Builder and Inspection Supervisor openings can be recessed, and will be complete for inspection at intermediate. |
| 11/22/2019 |
COT - RSBU - Exterior/Interior Clips/Sheathing/Framing |
RCHANDLER |
Correction Required |
Entered by DMERANZ1 - 1-Strap is not installed per approved plans.
2-Per Inspection manger, if window are not less than three feet from property line they can remain; installed window next door is 6’ 1/2" from rough frame of this house window opening. Combustion air openings are 5’ 9-1/2" apart, kitchen hood duct exhaust openings are 5’ 10" apart. Builder declines to obtain survey to determine where the property line is.
|
| 11/18/2019 |
COT - RSBU - Exterior/Interior Clips/Sheathing/Framing |
RCHANDLER |
Correction Required |
Entered by DMERANZ1 - 1-Still need strap at top played.
2-Need revision for firewalls required on both sides. |
| 11/08/2019 |
COT - RSBU - Exterior/Interior Clips/Sheathing/Framing |
DQUINN |
Denied |
Entered by DMERANZ1 - Missing rsp-4s on south wall studs, top and bottom.
Need continuity strap to tie angled roof top plates to blocking below the flat roof top plates. (SD2 #8) detail.
Check shear transfer nailing of between truss boxes, from roof and 2nd floor. |