Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Inspections
Type:
Residential Building - One or Two Family
Address:
990 W 34TH ST
Address NEW:
990 W 34TH ST
Apply Date:
09/25/2019
Applicant:
Jose Martinez
Description:
NEW SFR

Permit Reviews

Permit Number - T19CM07022
Permit Status: Inspections
Permit Description: NEW SFR
Start Date Submittal Complete Date Status  
09/25/2019 RESIDENTIAL - BLDG/ZONING-WALKTHRU 09/25/2019 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T19CM07022
Permit Status: Inspections
Permit Description: NEW SFR
Total Outstanding Activity Conditions - 3
Date Name
06/10/2021 PIMA COUNTY WASTEWATER SIGN OFF REQUIRED PRIOR TO ISSUANCE OF FINAL STATUS.
09/25/2019 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.
09/25/2019 ROOF TRUSSES MUST BE APPROVED PRIOR TO FRAMING INSPECTION (P2I)

Outstanding Inspections

Permit Status: Inspections
Permit Number: T19CM07022
Permite Description: NEW SFR
Total Outstanding Inspections - 10
Last Inspection Date Description Inspector Results Comments
10/27/2022 COT - RSME - Mechanical Final N/A Not Ready
10/27/2022 RSBU - Building Final N/A Not Ready
10/27/2022 COT - RSEL - Outdoor Lighting N/A Not Ready
10/27/2022 COT - RSEL - Electrical Final N/A Not Ready
10/27/2022 COT - RSPL - Plumbing Final N/A Not Ready
05/27/2026 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. N/A Re-inspection required 11/24/2025 Ensure lath and windows are in place prior to intermediate. Add nails to h25 clips. Add shot pins to interior walls 6" from edges and every 24" o.c. Pex lines have to be 12" from any can lights. Seal all exterior and top penetrations. Missing smoke detector in hallway. Flex duct have to be replace due to weather damage. Secure ABS pipes mid way throughout. Add Boca plates to both top and bottom plates at lines that are less than an 1 1/4". Secure pex lines ' vertically and 32" horizontally. Provide 18" off copper before transition to pex at main water line and water heater. Electrical panel is not grounded.
5/27/26: per previous notes, pex A using pex B fittings, damaged NM cable at master bedroom.
09/07/2023 COT - LCPL - Plumbing Intermediate N/A Not Ready
05/27/2026 RSEL - Electrical Progress N/A Re-inspection required 11/24/2025 Ensure lath and windows are in place prior to intermediate. Add nails to h25 clips. Add shot pins to interior walls 6" from edges and every 24" o.c. Pex lines have to be 12" from any can lights. Seal all exterior and top penetrations. Missing smoke detector in hallway. Flex duct have to be replace due to weather damage. Secure ABS pipes mid way throughout. Add Boca plates to both top and bottom plates at lines that are less than an 1 1/4". Secure pex lines ' vertically and 32" horizontally. Provide 18" off copper before transition to pex at main water line and water heater. Electrical panel is not grounded.
5/27/26: per previous notes, pex A using pex B fittings, damaged NM cable at master bedroom.
05/27/2026 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing N/A Re-inspection required 5/27/26: Not ready (shear panels throughout), anchor bolts required throughout
10/27/2022 COT - LCBU - Framing N/A Not Ready

Completed Inspections

Permit Status: Inspections
Permit Number: T19CM07022
Permit Description: NEW SFR
Total Completed Inspections - 11
Date Description Inspector Results Comments
05/10/2022 COT - RSEL - Grounding/Bonding Passed {Activity date: 05/10/2022; Status: Approved; Inspector: TGAUSP; Comment: Entered by NGARCIA3 - APPROVED}
05/10/2022 COT - RSBU - Preslab Passed {Activity date: 05/10/2022; Status: Approved; Inspector: TGAUSP; Comment: Entered by NGARCIA3 - APPROVED}
05/10/2022 COT - RSBU - Excavation/Rebar/Zoning Passed {Activity date: 05/10/2022; Status: Approved; Inspector: TGAUSP; Comment: Entered by NGARCIA3 - APPROVED}
03/14/2023 COT - RSBU - Roof Nailing Passed
07/10/2025 RSME - Mechanical Progress Passed All registers have been blocked on 3 sides.
05/15/2026 COT - RSPL - Rough Soil Passed 05/15/2026
Verified holding under test.
06/11/2026 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Passed
06/11/2026 COT - LCPL - Plumbing Intermediate Passed
06/11/2026 RSEL - Electrical Progress Passed
06/11/2026 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Passed
07/02/2026 COT - LCBU - Framing Passed

Documents

File Name Document Type  
PLOT PLAN.PDF CONSTRPLANS VIEW
PERMIT.PDF DOCUMENTS VIEW
APPLICATION.PDF DOCUMENTS VIEW
JOB CARD.PDF DOCUMENTS VIEW