Permit: T19CM04099
Permit Details
Status:
Expired
Type:
SINGLE FAMILY ADDITION
Address:
2009 S CAMILLA SV
Address NEW:
2009 S CAMILLA SV
Apply Date:
06/07/2019
Applicant:
DAN ROMERO
Description:
ADD BATHROOM/NEW AC & DUCT WORK/NEW ELECTRIC PANEL & WIRING
Contractors:
- PIMA VENTURES LLC
Permit Reviews
Permit Number - T19CM04099
Permit Status: Expired
Permit Description: ADD BATHROOM/NEW AC & DUCT WORK/NEW ELECTRIC PANEL & WIRING
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 06/07/2019 | RESIDENTIAL - BLDG/ZONING-WALKTHRU | 06/07/2019 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T19CM04099
Permit Status: Expired
Permit Description: ADD BATHROOM/NEW AC & DUCT WORK/NEW ELECTRIC PANEL & WIRING
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 06/07/2019 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Outstanding Inspections
Permit Status: Expired
Permit Number: T19CM04099
Permite Description: ADD BATHROOM/NEW AC & DUCT WORK/NEW ELECTRIC PANEL & WIRING
Total Outstanding Inspections - 2
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/25/2019 | BUILDING - FINAL | N/A | Partial Approval | SEE NOTES FOR 3090 |
| 07/25/2019 | PLUMBING - FINAL | N/A | Correction Required | Gas pipe exiting at the carport and around the corner to the water heater. Black iron gas pipe shall not be buried in the dirt/below grade. All metallic gas piping to be elevated, secured, and elevated 3 1/2 inches above the surface below it. Open up the gas pipe trench for inspection. Fletcher coated piping (is used in place of black iron uncoated pipe) with sprayed and taped fittings, this needs to be seen/inspected and approved. Spray and tape must be listed for the gas piping application, see plumbing supply house. |
Completed Inspections
Permit Status: Expired
Permit Number: T19CM04099
Permit Description: ADD BATHROOM/NEW AC & DUCT WORK/NEW ELECTRIC PANEL & WIRING
Total Completed Inspections - 10
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/25/2019 | PLUMBING - ROUGH, SOIL | AKLEINSORGE | Approved | Ok to backfill, master bathroom and 2nd bathroom |
| 06/25/2019 | BUILDING PRE-SLAB | AKLEINSORGE | Approved | Ok for concrete placement after backfill in master bathroom and 2nd bathroom, wrap all plumbing penetrations with foam before concrete placement |
| 06/25/2019 | TEP CLEARANCE - PM | AKLEINSORGE | Approved | CODE INCR |
| 06/27/2019 | RESIDENTIAL INTERMEDIATE | AKLEINSORGE | Approved | All corrections complete |
| 06/27/2019 | FRAMING | AKLEINSORGE | Approved | All corrections complete, finish installing nail protection plates where required before hanging drywall |
| 06/27/2019 | MECHANICAL - INTERMEDIATE | AKLEINSORGE | Approved | Correction complete |
| 07/19/2019 | ROOF NAILING | AKLEINSORGE | Approved | |
| 07/25/2019 | ELECTRIC - SERVICE UPGRADE | GWEST | Approved | APPROVED PER 2090 APPROVAL |
| 07/25/2019 | ELECTRIC - FINAL | GWEST | Approved | |
| 07/25/2019 | MECHANICAL - FINAL | GWEST | Approved |