Permit: T19CM04099

Parcel: 130110260


Addresses:

2009 S CAMILLA SV

Inspection Status: Correction Required

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
07/25/2019 PLUMBING - FINAL Correction Required Gas pipe exiting at the carport and around the corner to the water heater. Black iron gas pipe shall not be buried in the dirt/below grade. All metallic gas piping to be elevated, secured, and elevated 3 1/2 inches above the surface below it.

Open up the gas pipe trench for inspection. Fletcher coated piping (is used in place of black iron uncoated pipe) with sprayed and taped fittings, this needs to be seen/inspected and approved. Spray and tape must be listed for the gas piping application, see plumbing supply house.
07/19/2019 PLUMBING - FINAL Denied 1. Hammer arrestors needed at laundry connections and refrigerator
2. Cap off gas line at stove, until stove is installed. Also installed anti tip device when installing stove
06/25/2019 PLUMBING - FINAL Not ready for Inspection Recall at finals