Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
Expired
Type:
Residential Building - One or Two Family
Address:
6339 E LACO WY
Apply Date:
03/28/2019
Applicant:
Description:
SFR DOUC184918 T18-M0020

Permit Reviews

Permit Number - T19CM02202
Permit Status: Expired
Permit Description: SFR DOUC184918 T18-M0020
Start Date Submittal Complete Date Status  
03/28/2019 RESIDENTIAL - BLDG-MODEL PLAN/ENGINE/WALK THRU 03/28/2019 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T19CM02202
Permit Status: Expired
Permit Description: SFR DOUC184918 T18-M0020
Total Outstanding Activity Conditions - 1
Date Name
03/28/2019 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Conditions

Permit Number - T19CM02202
Permit Status: Expired
Permit Description: SFR DOUC184918 T18-M0020
Date Description Comments
03/28/2019 ROOF TRUSSES MUST BE APPROVED PRIOR TO FRAMING INSPECTION (P2I)
03/28/2019 SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED.

Outstanding Inspections

Permit Status: Expired
Permit Number: T19CM02202
Permite Description: SFR DOUC184918 T18-M0020
Total Outstanding Inspections - 1
Last Inspection Date Description Inspector Results Comments
10/04/2019 COT - RSPL - Gas Pressure Test N/A Canceled {Activity date: 10/04/2019; Status: Not Applicable; Inspector: DMUNIZ; Comment: Entered by DMERANZ1 - } ; {Activity date: 10/03/2019; Status: Cancelled; Inspector: IVR USER; Comment: Entered by IVR USER - IVRS - AP canceled} ; {Activity date: 10/01/2019; Status: Not Applicable; Inspector: TVALENCIA; Comment: Entered by DMERANZ1 - } ; {Activity date: 09/30/2019; Status: Cancelled; Inspector: IVR USER; Comment: Entered by IVR USER - IVRS - AP canceled} ; {Activity date: 09/27/2019; Status: Not Applicable; Inspector: DMUNIZ; Comment: Entered by DMERANZ1 - }

Completed Inspections

Permit Status: Expired
Permit Number: T19CM02202
Permit Description: SFR DOUC184918 T18-M0020
Total Completed Inspections - 20
Date Description Inspector Results Comments
04/12/2019 COT - RSPL - Yard Water Line Passed {Activity date: 04/12/2019; Status: Approved; Inspector: AKLEINSORGE; Comment: Entered by CBELL1 - }
04/12/2019 COT - RSPL - Sewer Passed {Activity date: 04/12/2019; Status: Approved; Inspector: AKLEINSORGE; Comment: Entered by CBELL1 - Ok to backfill}
04/12/2019 COT - RSPL - Rough Soil Passed {Activity date: 04/12/2019; Status: Approved; Inspector: AKLEINSORGE; Comment: Entered by CBELL1 - }
04/19/2019 COT - RSEL - Grounding/Bonding Passed {Activity date: 04/19/2019; Status: Approved; Inspector: AKLEINSORGE; Comment: Entered by CBELL1 - }
04/19/2019 COT - RSBU - Preslab Passed {Activity date: 04/19/2019; Status: Approved; Inspector: AKLEINSORGE; Comment: Entered by CBELL1 - Ok to pour}
04/19/2019 COT - RSEL - Electrical Underground Passed {Activity date: 04/19/2019; Status: Approved; Inspector: AKLEINSORGE; Comment: Entered by CBELL1 - }
04/19/2019 COT - RSBU - Excavation/Rebar/Zoning Passed {Activity date: 04/19/2019; Status: Approved; Inspector: AKLEINSORGE; Comment: Entered by CBELL1 - Ok to pour}
06/26/2019 COT - RSBU - Roof Nailing Passed {Activity date: 06/26/2019; Status: Approved; Inspector: DMUNIZ; Comment: Entered by DMERANZ1 - All corrections have been made, ok to proceed.} ; {Activity date: 06/24/2019; Status: Denied; Inspector: AKLEINSOGRE; Comment: Entered by DMERANZ1 - Multiple areas of missing nails on all elevations of roof}
06/26/2019 COT - RSBU - Exterior Clips/Sheathing Passed {Activity date: 06/26/2019; Status: Approved; Inspector: DMUNIZ; Comment: Entered by DMERANZ1 - All corrections have been made, ok to proceed.} ; {Activity date: 06/24/2019; Status: Denied; Inspector: AKLEINSOGRE; Comment: Entered by DMERANZ1 - Missing 4 locations of coil straps, and various locations throughout missing RSP4 clips

}
08/16/2019 COT - RSEL - Construction Power Passed {Activity date: 08/16/2019; Status: Approved; Inspector: DMUNIZ; Comment: Entered by DMERANZ1 - Clear TEP (ECO).}
08/16/2019 BULD - Electrical Clearance Passed {Activity date: 08/16/2019; Status: Approved; Inspector: DMUNIZ; Comment: Entered by DMERANZ1 - CODE ECO}
09/27/2019 RSME - Mechanical Progress Passed {Activity date: 09/27/2019; Status: Approved; Inspector: DMUNIZ; Comment: Entered by DMERANZ1 - }
10/04/2019 COT - LCBU - Framing Passed {Activity date: 10/04/2019; Status: Approved; Inspector: DMUNIZ; Comment: Entered by DMERANZ1 - } ; {Activity date: 10/01/2019; Status: Denied; Inspector: TVALENCIA; Comment: Entered by DMERANZ1 - 1- Second Floor Sanitary waste and vent does not set the requirements for horizontal wet venting per Section P3108 2012 IRC
2- Water lines to close to electric can lights
3- Retest the Sanitary system
4- Approved plans call out for the water supply line to the water heater shall be 11/4 inch in size. This is due to the wfu load of the hot water distribution.} ; {Activity date: 09/27/2019; Status: Denied; Inspector: DMUNIZ; Comment: Entered by DMERANZ1 - Fire Block and seal chases, Fire Block Top plate penetrations where needed. Provide anchor bolts at sill plate where needed.}
10/04/2019 COT - LCPL - Plumbing Intermediate Passed {Activity date: 10/04/2019; Status: Approved; Inspector: DMUNIZ; Comment: Entered by DMERANZ1 - } ; {Activity date: 10/01/2019; Status: Denied; Inspector: TVALENCIA; Comment: Entered by DMERANZ1 - 1- Second Floor Sanitary waste and vent does not set the requirements for horizontal wet venting per Section P3108 2012 IRC
2- Water lines to close to electric can lights
3- Retest the Sanitary system
4- Approved plans call out for the water supply line to the water heater shall be 11/4 inch in size. This is due to the wfu load of the hot water distribution.} ; {Activity date: 09/27/2019; Status: Denied; Inspector: DMUNIZ; Comment: Entered by DMERANZ1 - Repair damaged Pex lines (multiple locations). Provide DWV and Potable water test.}
02/05/2020 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Passed {Activity date: 02/05/2020; Status: Approved; Inspector: WGALLAG1; Comment: Entered by DMERANZ1 - } ; {Activity date: 10/02/2019; Status: Not ready for Inspection; Inspector: DMUNIZ; Comment: Entered by DMERANZ1 - Contractor rescheduled Via phone call.} ; {Activity date: 10/01/2019; Status: Denied; Inspector: TVALENCIA; Comment: Entered by DMERANZ1 - 1- Second Floor Sanitary waste and vent does not set the requirements for horizontal wet venting per Section P3108 2012 IRC
2- Water lines to close to electric can lights
3- Retest the Sanitary system
4- Approved plans call out for the water supply line to the water heater shall be 11/4 inch in size. This is due to the wfu load of the hot water distribution.} ; {Activity date: 09/27/2019; Status: Denied; Inspector: DMUNIZ; Comment: Entered by DMERANZ1 - multiple corrections needed.}
02/05/2020 COT - RSME - Mechanical Final Passed {Activity date: 02/05/2020; Status: Approved; Inspector: WGALLAG1; Comment: Entered by DMERANZ1 - }
02/05/2020 COT - RSEL - Outdoor Lighting Passed {Activity date: 02/05/2020; Status: Approved; Inspector: WGALLAG1; Comment: Entered by DMERANZ1 - }
02/05/2020 COT - RSPL - Plumbing Final Passed {Activity date: 02/05/2020; Status: Approved; Inspector: WGALLAG1; Comment: Entered by DMERANZ1 - }
02/05/2020 COT - RSEL - Electrical Final Passed {Activity date: 02/05/2020; Status: Approved; Inspector: WGALLAG1; Comment: Entered by DMERANZ1 - }
03/11/2020 RSBU - Building Final Passed {Activity date: 03/11/2020; Status: Approved; Inspector: KEN; Comment: Entered by KKARSEN1 - completed - PT posted 3/5/20} ; {Activity date: 02/05/2020; Status: Partial Approval; Inspector: WGALLAG1; Comment: Entered by DMERANZ1 - APPROVED BY INSPECTOR, PENDING SPECIAL INSPECTION CERTIFICATE FOR POST TENSION}

Documents

File Name Document Type  
HERS FORM.PDF DOCUMENTS VIEW
SIC DOUBLE STAMPED.PDF DOCUMENTS VIEW
None DOCUMENTS VIEW
None CONSTRPLANS VIEW