Permit: T18CM08709
Permit Details
Apply Date:
10/31/2018
Applicant:
METRO TUCSON EXPEDITING & DEVELOPMENT
Description:
RESTAURANT
Architects:
- FRANKS, MICHAEL WILLIAM
Contractors:
- MW MORRISSEY CONSTRUCTION LLC
Permit Reviews
Permit Number - T18CM08709
Permit Status: C of o
Permit Description: RESTAURANT
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 02/08/2019 | RESUBMITTAL | 03/06/2019 | COMPLETED |
| 03/06/2019 | RESUBMITTAL | 04/17/2019 | COMPLETED |
| 06/18/2019 | REVISION - - 1ST | 08/13/2019 | COMPLETED |
| 08/13/2019 | REVISION - - 2ND | 08/13/2019 | COMPLETED |
| 10/31/2018 | PLANS OK TO SUBMIT - COMM | 11/15/2018 | COMPLETED |
| 11/15/2018 | COMMERCIAL - NEW | 12/27/2018 | COMPLETED |
| 12/27/2018 | COMMERCIAL - NEW | 02/08/2019 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T18CM08709
Permit Status: C of o
Permit Description: RESTAURANT
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 10/31/2018 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: C of o
Permit Number: T18CM08709
Permit Description: RESTAURANT
Total Completed Inspections - 40
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/24/2019 | ELECTRIC - UFER | MHASSAN | Approved | |
| 05/24/2019 | EXCAVATION/LAYOUT REBAR & ZON | MHASSAN | Approved | clean debris’s out of footings and make sure all plumbing pipes that are within the footings are wrapped, before pour. |
| 05/31/2019 | ELECTRIC - UNDERGROUND | TVALENCIA | Approved | |
| 06/03/2019 | BUILDING PRE-SLAB | MHASSAN | Approved | |
| 06/17/2019 | PLUMBING - ROUGH, SOIL | RCAMACHO | Approved | |
| 07/24/2019 | EXT METAL CLIPS/EXT SHEATHING | JBURGE | Approved | Ok to cover exterior walls. |
| 08/01/2019 | ELECTRIC - INTERMEDIATE | ESTEVENS | Approved | |
| 08/05/2019 | FRAMING | TVALENCIA | Approved | |
| 08/05/2019 | ROOF NAILING | TVALENCIA | Approved | |
| 08/06/2019 | TEP CLEARANCE - AM | JBURGE | Approved | CODE TMPP |
| 08/07/2019 | TEP CLEARANCE - PM | JBURGE | Approved | CODE TMPP |
| 08/08/2019 | PLUMBING - GAS PRESSURE TEST | JBURGE | Approved | Not ready to set meter. |
| 08/08/2019 | PLUMBING - ABOVE CEILING | JBURGE | Approved | |
| 08/08/2019 | ELECTRIC - ABOVE CEILING | JBURGE | Approved | |
| 08/08/2019 | BUILDING ABOVE CEILING | JBURGE | Approved | Public building. |
| 08/16/2019 | MECHANICAL - ABOVE CEILING | JBURGE | Approved | |
| 08/19/2019 | MECHANICAL - INTERMEDIATE | JBURGE | Approved | |
| 09/18/2019 | ELECTRIC - PROGRESS | JBURGE | Approved | |
| 09/18/2019 | ELECTRIC - CONSTRUCTION POWER | JBURGE | Approved | |
| 09/18/2019 | BUILDING - PROGRESS | JBURGE | Approved | |
| 09/18/2019 | U VALUE FOR WINDOW | JBURGE | Approved | |
| 09/18/2019 | STUCCO MESH | JBURGE | Approved | |
| 09/18/2019 | STEM WALL/RETAINING WALL | JBURGE | Approved | |
| 10/07/2019 | FIRE SPKLR - FINAL | MRoss | Approved | |
| 10/16/2019 | ELECTRIC - FINAL | TVALENCIA | Approved | |
| 10/16/2019 | OUTDOOR LIGHTING FINAL | TVALENCIA | Approved | |
| 10/16/2019 | ELECTRIC - OUTDOOR LIGHTING | TVALENCIA | Approved | |
| 10/22/2019 | MECHANICAL - FINAL | JBURGE | Approved | |
| 10/22/2019 | MECHANICAL - HOODS | JBURGE | Approved | Ansul system tested while Fire Inspectors were present. |
| 10/22/2019 | PLUMBING - FINAL | JBURGE | Approved | |
| 10/22/2019 | PLUMBING - BACK WATER VALVE | JBURGE | Approved | |
| 10/22/2019 | PLUMBING - FINAL | RSHERRY | Approved | REVIEW OF WATER DISINFECTION REPORT COMPLETED |
| 10/22/2019 | MECHANICAL - FINAL | RSHERRY | Approved | REVIEW OF AIR BALANCE REPORT COMPLETED |
| 10/22/2019 | FIRE - KITCHEN EXH HOOD FINAL | jvincent | Approved | |
| 10/22/2019 | FIRE - ALARM FINAL | jvincent | Approved | |
| 12/05/2019 | ENGINEERING - FINAL | BBENEDON | Approved | |
| 12/05/2019 | FIRE - FINAL | MRoss | Approved | |
| 12/23/2019 | CERTIFICATE OF OCCUPANCY | JCLAXTON | Approved | |
| 12/23/2019 | BUILDING - FINAL | JCLAXTON | Approved | |
| 12/23/2019 | HEALTH DEPT - FINAL 724-7908 | PURBINA | Approved |